OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

5)Verify that the venting and cap are unobstructed.

6)Ensure that the brick panels are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

3)Turn gas control knob counterclockwise so indicator points to the "PILOT" position. Depress the gas control knob fully. Depress the igniter button several times until the pilot lights.After approximately one minute, release the gas control knob.The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob.

4)When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" position.

5)Use the wall switch, thermostat or remote control to turn on the unit.

6)Rotate the fl ame height regulator to adjust the fl ame height higher or lower.

SHUTDOWN

PROCEDURE

1)Use the wall switch, thermostat or remote control to turn off the main burner.

2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.

FIRST FIRE

AERATION

ADJUSTMENT

The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue fl ame or close for a yellower

ame. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

Minimum Air Shutter Opening:

3/16" Natural Gas

3/8" Propane

CAUTION: Carbon will be produced if air shutter is closed too much.

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot, remove one glass panel/door.

NOTE: For all propane units and units equipped with electric spark boxes, see "Copy of Lighting Plate Instruc- tions" section for more details.

Only when the pilot holds, without pressure being applied to the control knob, resecure the glass panel to the unit. The unit must not be

operated with the glass removed.

IMPORTANT Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

2)Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

The fi rst fi re in your fi replace is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time before you use it with the fan on.

When fi rst operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

Note: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

During the first few fires, a white film may develop on the glass front as part of the curingprocess.Theglassshouldbecleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

Adjustment Wire - Push to close or

pull to open aeration cap.

Closed - Tall yellow

Open - Short Blue

Note: Aeration Adjustment should only be performedbyanauthorizedRegency® Installer at the time of installation or service.

34

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

Image 34
Contents P121 / P121LC / P121RC / P131 Manufactured Mobile Home Requirements To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P121/P121LC/P121RC/P131Requirements MA Code CO DetectorInstallation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsSpecifications Non-load bearingP121LC-2 Left Corner Unit Locating Your GAS Fireplace Locations see section Exterior Vent Termination LocationsClearances Combustible MantelsP121-2 See Thru P131-2 Pier Framing DimensionsFraming and Finishing Corner UnitTop Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Exterior Vent Termination Locations VentHeight Meters Minimum Feet RoofPitchRigid Pipe Venting Components List SV4LB6Venting Arrangement Horizontal Terminations Rigid Pipe Venting Systems Horizontal or Vertical TerminationsRigid Pipe Venting Arrangements Horizontal Terminations Regency Direct Vent System Flex Propane & Natural GasHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsRigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasVertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsSet the unit in its desired location. Check This allows for small adjustments Vertical TerminationsOffset Chart Installation ProceduresFor Regency AstroCapTM Direct Vent System Flex Conversion KIT #731-969 from NG to LP LPG Conversion Kit Contains QtyInstallation of the DC Sparker Ground Wire from Kit GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationLOG Installation 327 329 326 328327 Louvers & Grills Finishing TrimP121-2 & P131-2 Corner Models Thermostat Wire Table Diagram belowWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Terminal Block LocationLighting Procedure Shutdown ProcedureFirst Fire Aeration Adjustment Operating InstructionsNormal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Removing Valve Remove Left & Right Side Base Brick PanelsInstalling Valve FAN ReplacementP121-2 see Thru Main Assembly Parts ListDescription P131-2 Pier Main Assembly P121RC-2 Right Corner Main Assembly 204 225P121LC-2 Left Corner Main Assembly P121/P121LC/P121RC/P131-2 Burner Assembly & LOG SET Page Page Page Warranty ConditionsInstaller Please complete the following information
Related manuals
Manual 40 pages 33.79 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.