Regency P121RC, P121LC, P131 installation manual Locating Your GAS Fireplace

Page 9

INSTALLATION

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fi replace, ensure that the clearances are met as outlined in the "Clearances" section.

2)Provide adequate clearances for servicing.

3)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood fl ooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

4)The Direct Vent Gas Fireplace can be installed as follows:

 

Model #

Position

A)

P121-2:

See Thru

B)

P131-2:

Pier

C)

P121LC-2:

Left Corner

D)

P121RC-2:

Right Corner

A) P121-2 See Thru

B) P131-2 Pier

5)This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6)The P121-2/P121LC-2/P121RC-2/P131- 2 Direct Vent Gas Fireplace is approved

for alcove installations, which meet the C) P121LC-2 Left Corner clearances listed on this page.

7)Werecommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualifi ed inspector, dealer, or installer review your plans before installation.

Note: For Exterior Vent Termination

Locations see section "Exterior Vent

Termination Locations."

D) P121RC-2 Right Corner

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

9

Image 9
Contents P121 / P121LC / P121RC / P131 To the New Owner Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal for P121/P121LC/P121RC/P131 Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationInstallation Checklist Important Message Save These InstructionsNon-load bearing SpecificationsP121LC-2 Left Corner Unit Locations see section Exterior Vent Termination Locations Locating Your GAS FireplaceCombustible Mantels ClearancesFraming and Finishing Framing DimensionsP121-2 See Thru P131-2 Pier Corner UnitUnit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction VentHeight Meters Minimum Feet RoofPitch Exterior Vent Termination LocationsSV4LB6 Rigid Pipe Venting Components ListVenting Arrangement Horizontal Terminations Horizontal or Vertical Terminations Rigid Pipe Venting SystemsRegency Direct Vent System Flex Propane & Natural Gas Rigid Pipe Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsSet the unit in its desired location. Check Vertical Terminations This allows for small adjustmentsInstallation Procedures Offset ChartFor Regency AstroCapTM Direct Vent System Flex LPG Conversion Kit Contains Qty Conversion KIT #731-969 from NG to LPInstallation of the DC Sparker Ground Wire from Kit GAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High Elevation327 329 326 328 LOG Installation327 Finishing Trim Louvers & GrillsP121-2 & P131-2 Corner Models Diagram below Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsTerminal Block Location For Propane Units and Units Equipped with DC Spark BoxesFirst Fire Aeration Adjustment Shutdown ProcedureLighting Procedure Operating InstructionsCopy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Remove Left & Right Side Base Brick Panels Removing ValveFAN Replacement Installing ValveParts List P121-2 see Thru Main AssemblyDescription P131-2 Pier Main Assembly 204 225 P121RC-2 Right Corner Main AssemblyP121LC-2 Left Corner Main Assembly P121/P121LC/P121RC/P131-2 Burner Assembly & LOG SET Page Page Page Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 40 pages 33.79 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.