Regency P121LC, P131 installation manual P121RC-2 Right Corner Main Assembly, 204 225

Page 41

PARTS LIST

P121RC-2 (RIGHT CORNER) MAIN ASSEMBLY

Part #

Description

Part #

Description

Part #

Description

1)360-528 Door Assy Front - Tempered

360-538 Door Assy Front - Ceramic (Optional)

2)360-529 Door Assy Side - Tempered

360-539 Door Assy Side - Ceramic (Optional)

9)360-046 Nailing Strip - Top - Front

10)360-047 Nailing Strip - Top - Side

11)430-001 Standoff - Top

 

780-013

Standoff - Rear

17)

360-086

Gasket - Relief Door

24)

*

Relief Door Assembly

32)

362-528

Brick Panel Base (Set of 6)

34)902-603 Brick Panel - Side Std. Red

35)902-604 Brick Panel - Front Std. Red

1

204

225

98)

910-366

Switch Cover Plate

173)

360-932

Louver Side - Black (set)

99)

910-363

Wall Switch

 

360-934

Louver Side - Black/Gold (set)

100)

910-367

Switch Receptacle Plastic

 

360-936

Louver Side - Black/Steel (set)

Box

910-882

Wire - Valve to Burner Switch

 

360-938

Louver Side - Black/Brass (set)

 

181)

*

Extension Trim

138)

360-063

Heat Shield - Front

204)

360-940

Dec. Grill Front - Black (set)

141)

360-031

Column Finishing Trim

 

 

 

206)

910-171

Fan Axial 115V

146)

360-035

Finishing Trim - Left Side

224)

360-942

Dec. Grill Side - Black (set)

149)

360-122

Magnet Bracket - Corner

225)

948-216

Regency® Logo Plate

150)

360-123

Magnet Bracket - Front

226)

910-142

Thermodisc

151)

904-258

Magnet

 

918-519

Manual

158)

360-060

Door Cover Assembly-Front

 

171)

360-920

Louver Front - Black (set)

*Not available as a replacement part.

 

360-922

Louver Front - Black/Gold (set)

 

 

 

 

360-924

Louver Front - Black/Steel (set)

 

 

 

 

360-926

Louver Front - Black/Brass (set)

 

 

 

34

171

35

100181

99

98

 

 

 

 

32

24

 

BR ICK PANELS

11

146

 

 

17

171

225

141

204

224

173

10

9

206

158

149

2 151

206

151

138

224

146 150 226

173

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

41

Image 41
Contents P121 / P121LC / P121RC / P131 To the New Owner Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal for P121/P121LC/P121RC/P131 Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationInstallation Checklist Important Message Save These InstructionsNon-load bearing SpecificationsP121LC-2 Left Corner Unit Locations see section Exterior Vent Termination Locations Locating Your GAS FireplaceCombustible Mantels ClearancesFraming and Finishing Framing DimensionsP121-2 See Thru P131-2 Pier Corner UnitVenting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly VentHeight Meters Minimum Feet RoofPitch Exterior Vent Termination LocationsSV4LB6 Rigid Pipe Venting Components ListVenting Arrangement Horizontal Terminations Horizontal or Vertical Terminations Rigid Pipe Venting SystemsRegency Direct Vent System Flex Propane & Natural Gas Rigid Pipe Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsSet the unit in its desired location. Check Vertical Terminations This allows for small adjustmentsFor Regency AstroCapTM Direct Vent System Flex Installation ProceduresOffset Chart LPG Conversion Kit Contains Qty Conversion KIT #731-969 from NG to LPInstallation of the DC Sparker Ground Wire from Kit GAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High Elevation327 329 326 328 LOG Installation327 P121-2 & P131-2 Corner Models Finishing TrimLouvers & Grills Diagram below Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsTerminal Block Location For Propane Units and Units Equipped with DC Spark BoxesFirst Fire Aeration Adjustment Shutdown ProcedureLighting Procedure Operating InstructionsCopy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Remove Left & Right Side Base Brick Panels Removing ValveFAN Replacement Installing ValveDescription Parts ListP121-2 see Thru Main Assembly P131-2 Pier Main Assembly 204 225 P121RC-2 Right Corner Main AssemblyP121LC-2 Left Corner Main Assembly P121/P121LC/P121RC/P131-2 Burner Assembly & LOG SET Page Page Page Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 40 pages 33.79 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.