Regency P121RC, P131 installation manual P121LC-2 Left Corner Main Assembly

Page 42

PARTS LIST

P121LC-2 (LEFT CORNER) MAIN ASSEMBLY

Part #

Description

 

Part #

Description

1) 360-528

Door Assy Front - Tempered

98)

910-366

Switch Cover Plate

360-538

Door Assy Front - Ceramic

99)

910-363

Wall Switch

 

(Optional)

100) 910-367

Switch Receptacle Plastic Box

 

 

 

910-882

Wire - Valve to Burner Switch

2)360-529 Door Assy Side - Tempered

 

360-539

Door Assy Side - Ceramic

138) 360-069

Heat Shield - Front

 

 

(Optional)

141) 360-031

Column Finishing Trim

 

 

 

9)

360-046

Nailing Strip - Top - Front

146) 360-035

Finishing Trim

10)

360-047

Nailing Strip - Top - Side

149) 360-122

Magnet Bracket - Corner

11)

430-001

Standoff - Top

 

 

 

150) 360-123

Magnet Bracket - Front

17)

360-086

Gasket - Relief Door

151) 904-258

Magnet

24)

*

Relief Door Assembly

158) 360-062

Door Cover Assembly-Front

32)

362-528

Brick Panel Base (Set of 6)

171) 360-920

Louver Front - Black (set)

34)

902-603

Brick Panel - Side Std. Red

35)

902-604

Brick Panel - Front Std. Red

360-922

Louver Front - Black/Gold (set)

 

 

 

360-924

Louver Front - Black/Steel (set)

 

 

 

360-926

Louver Front - Black/Brass (set)

Part # Description

173)360-932 Louver Side - Black (set)

360-934 Louver Side - Black/Gold

(set)

 

 

 

 

360-936

Louver

Side

-

Black/Steel

(set)

 

 

 

 

360-938

Louver

Side

-

Black/Brass

(set)

 

 

 

 

204) 360-940

Dec. Grill Front - Black (set)

206) 910-171

Fan Axial 115V

 

224)360-942 Dec. Grill Side - Black (set)

225)948-216 Regency® Logo Plate

226)910-142 Thermodisc

918-519 Manual

*Not available as a replacement part.

34

35

100 181

99

98

158

138

24

1132

BR ICK PANELS

17

10

9

206

146

171

173

206

1

2

150

151

 

146

226

 

149

204

 

141

151

171

 

224

173

225

224

204

225

42

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

Image 42
Contents P121 / P121LC / P121RC / P131 Manufactured Mobile Home Requirements To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P121/P121LC/P121RC/P131Requirements MA Code CO DetectorInstallation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsSpecifications Non-load bearingP121LC-2 Left Corner Unit Locating Your GAS Fireplace Locations see section Exterior Vent Termination LocationsClearances Combustible MantelsP121-2 See Thru P131-2 Pier Framing DimensionsFraming and Finishing Corner UnitUnit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Exterior Vent Termination Locations VentHeight Meters Minimum Feet RoofPitchRigid Pipe Venting Components List SV4LB6Venting Arrangement Horizontal Terminations Rigid Pipe Venting Systems Horizontal or Vertical TerminationsRigid Pipe Venting Arrangements Horizontal Terminations Regency Direct Vent System Flex Propane & Natural GasHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsRigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasVertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsSet the unit in its desired location. Check This allows for small adjustments Vertical TerminationsInstallation Procedures Offset ChartFor Regency AstroCapTM Direct Vent System Flex Conversion KIT #731-969 from NG to LP LPG Conversion Kit Contains QtyInstallation of the DC Sparker Ground Wire from Kit GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationLOG Installation 327 329 326 328327 Finishing Trim Louvers & GrillsP121-2 & P131-2 Corner Models Thermostat Wire Table Diagram belowWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Terminal Block LocationLighting Procedure Shutdown ProcedureFirst Fire Aeration Adjustment Operating InstructionsNormal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Removing Valve Remove Left & Right Side Base Brick PanelsInstalling Valve FAN ReplacementParts List P121-2 see Thru Main AssemblyDescription P131-2 Pier Main Assembly P121RC-2 Right Corner Main Assembly 204 225P121LC-2 Left Corner Main Assembly P121/P121LC/P121RC/P131-2 Burner Assembly & LOG SET Page Page Page Warranty ConditionsInstaller Please complete the following information
Related manuals
Manual 40 pages 33.79 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.