Regency P33-LP4 Normal Operating Sounds Maintenance, GAS Appliances, Brass Louvers Trim

Page 43

MAINTENANCE

NORMAL OPERATING

SOUNDS OF

MAINTENANCE

GENERAL VENT

INSTRUCTIONS

MAINTENANCE

GAS APPLIANCES

It is possible that you will hear some sounds from your gas appliance.This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples.All are normal operatingsoundsandshouldnotbeconsidered as defects in your appliance.

Blower:

Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

Burner Tray:

The burner tray is positioned directly under the burnertube(s)andlogsandismadeofadifferent gauge material from the rest of the fi rebox and body.Therefore,thevaryingthicknessesofsteel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.

Blower Thermodisc:

When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.

Pilot Flame:

While the pilot fl ame is on it can make a very slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

Unit Body/Firebox:

1)Alwaysturnoffthegasvalvebeforecleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2)Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fi replace glass cleaner.

The glass should be cleaned when it starts looking cloudy.

3)The heater is fi nished in a heat resistant paint and should only be refinished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.

4)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed service person.

5)The appliance and venting system must be inspected before use, and at least annually, by a qualifi ed fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

Note: Never operate the appliance without the glass properly secured in place.

6)Donotusethisapplianceifanyparthasbeen under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.

7)Verify operation after servicing.

Conduct an inspection of the venting system semi-annually.Recommendedareastoinspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, andinextremecases,holes.Thesecompo- nents should be replaced immediately.

2)Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

GOLD-PLATED or

BRASS LOUVERS/

TRIM

The 24 carat gold-plated or brass fi nish on the louvers and trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty. Clean any fingerprints off before turning the unit on.

Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

LOG REPLACEMENT

Theunitshouldneverbeusedwithbrokenlogs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will severelyaltertheunit'sperformance which is not covered under warranty.

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

43

Image 43
Contents P33-4 Zero Clearance To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Safety LabelFor the State of Massachusetts only RequirementsBefore YOU Start InstallationGeneral Safety Information Important MessageDuct System Option Installation ChecklistUnit Dimensions Locating Your FireplaceMantel LEG Clearances ClearancesVertical Termination or Vertical Rise with Horizontal Framing and FinishingRear Termination Top Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting Introduction= Clearance to permanently closed window *min /30cm Exterior Vent Termination LocationsWithout any joints or seams Regency Direct Vent Flex SystemHorizontal Terminations Only AlternateFor Regency Direct Vent System Flex Installation ProceduresMinimum and Maximum Vent Clearances Max. Wall Flat Wall InstallationVent Length Thickness inches Required inchesDescription 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Vertical Terminations Propane & Natural Gas Rigid Pipe Venting ArrangementsInstallation Regency Direct Vent System Flex Option +H1 Horizontal Venting with Two 2 90o ElbowsOption + H1 Option +H1+H2Option +V1 Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Option +V1 +H1Vertical Venting with Three 3 90o Elbows Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionHorizontal Distance Feet Venting Arrangements Vertical TerminationsSnorkel Terminations Unit Installation with Horizontal TerminationGAS Line Installation Unit Installation With Vertical TerminationThis allows for small adjustments T. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationConversion KIT# 434-969 from NG to LP For P33-4/H25-1 Using SIT 820 Nova Gas ValveGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 251 2505th Grate Tab Standard Flush DoorOptional Flush Trim CutoutOptional BAY Door Flush LouversDouble Screen Door Optional BAY TrimBurner ON/OFF Control box BAY LouversFlush Louver Top Heat Shield Bay Louver Top Heat ShieldCut-Out Oblong Hole Top Flange Bottom Full Screen DoorsCut-Outs Top Grill Hinge Location Bottom GrillWall Thermostat Remote ControlWall Switch Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Secure the 2 boxes together With one screw Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsOperating Instructions Lighting ProcedureShutdown Procedure Aeration AdjustmentGAS Appliances MaintenanceNormal Operating Sounds Maintenance LOG ReplacementGlass Gasket Flush Glass ReplacementBay Glass Replacement Thermopile ThermocoupleRemoving Valve Installing ValveDiagram 3 Lift out Valve Tray Assembly Diagram 2 Rear Log Stand & Valve Tray AssemblyMain Assembly Parts ListDescription Parts List Part Description Burner & LOG AssemblyFlush Front & Louvers BAY Front & Louvers Conditions WarrantyInstaller Please complete the following information

P33-LP4 specifications

Regency P33-LP4 is an innovative and versatile propane gas fireplace designed to provide both warmth and ambiance while enhancing the aesthetic appeal of any living space. This model stands out for its combination of modern technology, functionality, and elegance, making it a popular choice among homeowners seeking an efficient heating solution without sacrificing style.

One of the key features of the P33-LP4 is its contemporary design. The fireplace presents a sleek, minimalist look that integrates seamlessly into both traditional and modern interiors. It offers a range of finishing options, including various trims and glass fronts, allowing homeowners to tailor the appearance of the fireplace to their personal taste and existing decor.

A hallmark of the Regency P33-LP4 is its advanced heating capabilities. With a powerful output of up to 33,000 BTUs, this fireplace can efficiently heat spaces of different sizes, making it suitable for both small cozy rooms and larger open areas. The unit also features a high-efficiency burner that maximizes heat production while reducing fuel consumption, which is ideal for energy-conscious users.

In terms of technology, the P33-LP4 boasts a user-friendly electronic ignition system that ensures reliable startups, even in colder temperatures. The fireplace can be controlled through a convenient remote or a wall switch, allowing users to adjust the flame height and heat settings with ease. Additionally, the unit incorporates a fan that circulates warm air throughout the room, enhancing overall heating efficiency and comfort.

Safety is paramount in the design of the Regency P33-LP4. The fireplace is equipped with a built-in safety shut-off feature that automatically turns off the gas supply in case of an unexpected accident. Moreover, the glass front remains cool to the touch, reducing the risk of burns and making it family-friendly.

Flexibility is another advantage of the P33-LP4, as it can be installed in various configurations, including as a built-in unit or a freestanding fireplace. The options for installation enable homeowners to create a unique focal point in their living space, adapting to different architectural layouts.

In conclusion, the Regency P33-LP4 combines contemporary design, efficient heating technology, and safety features, making it an excellent choice for those seeking a stylish and functional propane fireplace. Its versatility and reliability enhance the home environment while providing a warm and inviting atmosphere for family and guests.