Regency P33-LP4 installation manual 250, 251

Page 31

INSTALLATION

OPTIONAL BRICK

LOG SET INSTALLATION

 

PANELS

D) 251

A) 250

1)Undo the bottom 2 door latches and open and remove glass door. Remove logs.

2)Attach the 2 Rear Brick Retaining clips to the rear wall. Loosen the screws in the top and rear wall of the fi rebox and slide the retaining clips into position (tight against the fi rebox top) and then tighten the screws.

Note: The logs must not be in the unit.

3)Insert the back brick panel by carefully slipping it between the back wall of the fi rebox and the rear log bracket.

Readtheinstructions belowcarefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The 3-digit numbers (i.e. 250) are molded into the rear of each log.

Log Kit # 431-930 contains the following pieces:

A)250 Rear Log

B)254 Middle Cross Log

C)253 Front Left Cross Log

D)251 Rear Left Log

E)252 Front Right Cross Log

F)

Embers

902-156

G)

Vermiculite

902-179

H)

Rock Wool

902-153

I)

Platinum Embers

946-669

(supplied with packaged manual)

NOTE: If you will be installing the optional Brick Panels, install the Brick Panels prior to installing the logs.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the vermiculite and embers around the fi rebox base.

C) 253

B) 254

E) 252

4)Place Log 254 on the front right side of the burner. Push the back of the log against the 2 brackets with the notch on the bottom right side of the log fi tting into the right side of the grate.

Notch

254

BracketBracket

4)Put the side panels in next. Slide them in from the front and push them fl at up against the wall. Be very careful not to scratch them on the fi rebox hardware.

250

254

5)Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws.

Vermiculite Vermiculite Vermiculite

3)Place the Log 250 on the rear log support pins with the fl at side to the back.

250

5)Position Log 253 across the cutouts in Logs 250 and 254 with the notch on the left side of the log fi tting into the 2nd grate tab.

Cutouts

253

250

254

2nd Grate Tab

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

31

Image 31
Contents P33-4 Zero Clearance To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Safety LabelFor the State of Massachusetts only RequirementsBefore YOU Start InstallationGeneral Safety Information Important MessageDuct System Option Installation ChecklistUnit Dimensions Locating Your FireplaceMantel LEG Clearances ClearancesVertical Termination or Vertical Rise with Horizontal Framing and FinishingRear Termination Top Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting Introduction= Clearance to permanently closed window *min /30cm Exterior Vent Termination LocationsWithout any joints or seams Regency Direct Vent Flex SystemHorizontal Terminations Only AlternateFor Regency Direct Vent System Flex Installation ProceduresMinimum and Maximum Vent Clearances Max. Wall Flat Wall InstallationVent Length Thickness inches Required inchesDescription 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Vertical Terminations Propane & Natural Gas Rigid Pipe Venting ArrangementsInstallation Regency Direct Vent System Flex Option +H1 Horizontal Venting with Two 2 90o ElbowsOption + H1 Option +H1+H2Option +V1 Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Option +V1 +H1Vertical Venting with Three 3 90o Elbows Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionHorizontal Distance Feet Venting Arrangements Vertical TerminationsSnorkel Terminations Unit Installation with Horizontal TerminationGAS Line Installation Unit Installation With Vertical TerminationThis allows for small adjustments T. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationConversion KIT# 434-969 from NG to LP For P33-4/H25-1 Using SIT 820 Nova Gas ValveGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 251 2505th Grate Tab Standard Flush DoorOptional Flush Trim CutoutOptional BAY Door Flush LouversDouble Screen Door Optional BAY TrimBurner ON/OFF Control box BAY LouversFlush Louver Top Heat Shield Bay Louver Top Heat ShieldCut-Out Oblong Hole Top Flange Bottom Full Screen DoorsCut-Outs Top Grill Hinge Location Bottom GrillWall Thermostat Remote ControlWall Switch Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Secure the 2 boxes together With one screw Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsOperating Instructions Lighting ProcedureShutdown Procedure Aeration AdjustmentGAS Appliances MaintenanceNormal Operating Sounds Maintenance LOG ReplacementGlass Gasket Flush Glass ReplacementBay Glass Replacement Thermopile ThermocoupleRemoving Valve Installing ValveDiagram 3 Lift out Valve Tray Assembly Diagram 2 Rear Log Stand & Valve Tray AssemblyMain Assembly Parts ListDescription Parts List Part Description Burner & LOG AssemblyFlush Front & Louvers BAY Front & Louvers Conditions WarrantyInstaller Please complete the following information

P33-LP4 specifications

Regency P33-LP4 is an innovative and versatile propane gas fireplace designed to provide both warmth and ambiance while enhancing the aesthetic appeal of any living space. This model stands out for its combination of modern technology, functionality, and elegance, making it a popular choice among homeowners seeking an efficient heating solution without sacrificing style.

One of the key features of the P33-LP4 is its contemporary design. The fireplace presents a sleek, minimalist look that integrates seamlessly into both traditional and modern interiors. It offers a range of finishing options, including various trims and glass fronts, allowing homeowners to tailor the appearance of the fireplace to their personal taste and existing decor.

A hallmark of the Regency P33-LP4 is its advanced heating capabilities. With a powerful output of up to 33,000 BTUs, this fireplace can efficiently heat spaces of different sizes, making it suitable for both small cozy rooms and larger open areas. The unit also features a high-efficiency burner that maximizes heat production while reducing fuel consumption, which is ideal for energy-conscious users.

In terms of technology, the P33-LP4 boasts a user-friendly electronic ignition system that ensures reliable startups, even in colder temperatures. The fireplace can be controlled through a convenient remote or a wall switch, allowing users to adjust the flame height and heat settings with ease. Additionally, the unit incorporates a fan that circulates warm air throughout the room, enhancing overall heating efficiency and comfort.

Safety is paramount in the design of the Regency P33-LP4. The fireplace is equipped with a built-in safety shut-off feature that automatically turns off the gas supply in case of an unexpected accident. Moreover, the glass front remains cool to the touch, reducing the risk of burns and making it family-friendly.

Flexibility is another advantage of the P33-LP4, as it can be installed in various configurations, including as a built-in unit or a freestanding fireplace. The options for installation enable homeowners to create a unique focal point in their living space, adapting to different architectural layouts.

In conclusion, the Regency P33-LP4 combines contemporary design, efficient heating technology, and safety features, making it an excellent choice for those seeking a stylish and functional propane fireplace. Its versatility and reliability enhance the home environment while providing a warm and inviting atmosphere for family and guests.