Regency P33-LP4 installation manual Mantel LEG Clearances

Page 8

INSTALLATION

CLEARANCES

COMBUSTIBLE MANTELS

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Clearance to Combustibles from:

Back

0"

(0mm)

Side

0"

(0mm)

Floor

0"

(0mm)

NOTE: The minimum fl oor clearance must be maintained from the top surface of the carpeting, tile, etc.

Minimum Clearance from Top of Unit to:

Mantel*

min. 7" (177mm)

Ceiling

30"

(762mm)

from top of unit.

 

 

Side Wall Clearance

 

 

Bay or Flush Front

7-1/2"

(191mm)

Minimum Vent Clearances:

2-1/2" (64mm) Horizontal Top

1-1/2" (38mm) Horizontal Side

1-1/2" (38mm) Horizontal Bottom

1-1/4" (32mm) Vertical Vent Clearance

(Rigid Vent)

1-1/2" (38mm) Vertical Vent Clearance

(Flex Vent)

Alcove Clearances:

 

 

Max. Depth

36"

(914mm)

Min. Width

48"

(1219mm)

Min. Height

59"

(1499mm)

* see mantel clearance instructions.

Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

This drawing is to scale at 1:6 (one inch = 6 inches). Mantel can be installed anywhere in shaded area or higher using the above scale.

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

WARNING

Fire hazard is an extreme risk if these clearances are not adhered to.

Clearances for Bay or Flush Front

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram below:

Maximum

1-1/2" projection at 2" minimum clearance.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

8

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

Image 8
Contents P33-4 Zero Clearance Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Safety LabelRequirements For the State of Massachusetts onlyInstallation General Safety InformationImportant Message Before YOU StartInstallation Checklist Unit DimensionsLocating Your Fireplace Duct System OptionClearances Mantel LEG ClearancesRear Termination Framing and FinishingVertical Termination or Vertical Rise with Horizontal Unit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Top Facing Support Side Nailing StripsExterior Vent Termination Locations = Clearance to permanently closed window *min /30cmRegency Direct Vent Flex System Horizontal Terminations OnlyAlternate Without any joints or seamsMinimum and Maximum Vent Clearances Installation ProceduresFor Regency Direct Vent System Flex Flat Wall Installation Vent LengthThickness inches Required inches Max. Wall6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasInstallation Regency Direct Vent System Flex Horizontal Venting with Two 2 90o Elbows Option + H1Option +H1+H2 Option +H1Horizontal Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsOption +V1 +H1 Option +V1Vertical Venting with Three 3 90o Elbows Vertical Termination With CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsVenting Arrangements Vertical Terminations Horizontal Distance FeetUnit Installation with Horizontal Termination Snorkel TerminationsThis allows for small adjustments Unit Installation With Vertical TerminationGAS Line Installation Pilot Adjustment GAS Pipe Pressure TestingHigh Elevation T. Valve DescriptionFor P33-4/H25-1 Using SIT 820 Nova Gas Valve Conversion KIT# 434-969 from NG to LPGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 250 251Standard Flush Door Optional Flush TrimCutout 5th Grate TabFlush Louvers Double Screen DoorOptional BAY Trim Optional BAY DoorBAY Louvers Flush Louver Top Heat ShieldBay Louver Top Heat Shield Burner ON/OFF Control boxCut-Outs Full Screen DoorsCut-Out Oblong Hole Top Flange Bottom Hinge Location Bottom Grill Top GrillRemote Control Wall SwitchThermostat Wire Table Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Installing the Optional FAN Secure the 2 boxes together With one screwOperating Instructions Copy of the Lighting Plate InstructionsLighting Procedure Shutdown ProcedureAeration Adjustment Operating InstructionsMaintenance Normal Operating Sounds MaintenanceLOG Replacement GAS AppliancesFlush Glass Replacement Bay Glass ReplacementThermopile Thermocouple Glass GasketInstalling Valve Diagram 3 Lift out Valve Tray AssemblyDiagram 2 Rear Log Stand & Valve Tray Assembly Removing ValveDescription Parts ListMain Assembly Parts List Burner & LOG Assembly Part DescriptionFlush Front & Louvers BAY Front & Louvers Warranty ConditionsInstaller Please complete the following information

P33-LP4 specifications

Regency P33-LP4 is an innovative and versatile propane gas fireplace designed to provide both warmth and ambiance while enhancing the aesthetic appeal of any living space. This model stands out for its combination of modern technology, functionality, and elegance, making it a popular choice among homeowners seeking an efficient heating solution without sacrificing style.

One of the key features of the P33-LP4 is its contemporary design. The fireplace presents a sleek, minimalist look that integrates seamlessly into both traditional and modern interiors. It offers a range of finishing options, including various trims and glass fronts, allowing homeowners to tailor the appearance of the fireplace to their personal taste and existing decor.

A hallmark of the Regency P33-LP4 is its advanced heating capabilities. With a powerful output of up to 33,000 BTUs, this fireplace can efficiently heat spaces of different sizes, making it suitable for both small cozy rooms and larger open areas. The unit also features a high-efficiency burner that maximizes heat production while reducing fuel consumption, which is ideal for energy-conscious users.

In terms of technology, the P33-LP4 boasts a user-friendly electronic ignition system that ensures reliable startups, even in colder temperatures. The fireplace can be controlled through a convenient remote or a wall switch, allowing users to adjust the flame height and heat settings with ease. Additionally, the unit incorporates a fan that circulates warm air throughout the room, enhancing overall heating efficiency and comfort.

Safety is paramount in the design of the Regency P33-LP4. The fireplace is equipped with a built-in safety shut-off feature that automatically turns off the gas supply in case of an unexpected accident. Moreover, the glass front remains cool to the touch, reducing the risk of burns and making it family-friendly.

Flexibility is another advantage of the P33-LP4, as it can be installed in various configurations, including as a built-in unit or a freestanding fireplace. The options for installation enable homeowners to create a unique focal point in their living space, adapting to different architectural layouts.

In conclusion, the Regency P33-LP4 combines contemporary design, efficient heating technology, and safety features, making it an excellent choice for those seeking a stylish and functional propane fireplace. Its versatility and reliability enhance the home environment while providing a warm and inviting atmosphere for family and guests.