WARNING:FOR YOUR SAFETY
If the information in these instructions are not followed exactly, What to do if you smell gas:
a fire or explosion may result causing property damage, Do not try to light any appliance
personal injury or loss of life.Do not touch any electrical switch: do not use any phone in your
building.
Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
www.regency-fire.com
Tested by:

Regency BellavistaB36X

Gas Fireplace

Owners &

Installation Manual

MODEL: B36X

Medium DV Gas Fireplace

918-759

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4

02/05/09

Image 1
Contents Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions DimensionsGeneral Safety Information InstallationImportant Message Save These Instructions Before YOU StartDiagram Installation ChecklistLocating Your GAS Fireplace Heatwave Duct System OptionalClearances Mantel LEG Clearances Mantel ClearancesFraming Framing Dimensions Description B36XImportant Finishing Detail Note FinishingFull Screen Doors Only Screw Position Unit Assembly Prior to Installation Before YOU StartPlates can be Folded out Adjustable Tension Latch location Unit Assembly Prior to InstallationBaffle Plate Diagram Exhaust Assembly Intake Collar Exhaust Assembly Intake Collar DiagramVenting Introduction Minimum Clearance Requirements Exterior Vent Termination RequirementsInstallation Vertical Venting Configurations Approved Venting Configurations6-5/8 Rigid Pipe Cross Reference ChartInstallation Installation Installation Horizontal Terminations Regency Direct Vent Flex System 5 X Horizontal Termination Horizontal Terminations Rigid Pipe Venting Arrangements 5 XTop Vent No Vertical Rise Rear Vent w/ Horizontal TerminationHorizontal or Vertical Terminations Rigid Pipe Venting Systems58DVA-WT Allowable Vertical Terminations Venting Arrangements6 5/8 Pipe Venting Arrangements Horizontal Venting with TWO 2 90O Elbows Venting Arrangements Horizontal TerminationVertical Venting with Three 3 90O Elbows Horizontal Venting with Three 3 90O ElbowsAlternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemFor Both Residential & Manufactured Homes Rigid Vent Systems Astrocapxl Unit InstallationGAS Line Installation Unit Installation With Vertical TerminationThis allows for small adjustments GAS Pipe Pressure Testing Pilot AdjustmentHigh Elevation T. Valve DescriptionWiring Diagram Aeration AdjustmentMinimum Air Shutter Opening Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Wiring Diagram for Gtmf RemoteDiagram 2 Vent restrictor installed on top exhaust assembly Vent RESTRICTOR, Baffle & Heat Deflector InstallationBaffl e Plate Heat Defl ectorConversion Kit Contains Qty Description Conversion KIT# 556-969 from NG to LPShut off the gas supply Cap Ignitor Wire Piezo DC Sparker InstallationSparker Ignitor Wire DC Sparker Generator WiresBack Panel Installed Final Brick Panel Installation Brick Panel InstallationHandle with care. do not Force Into Position Ensure that the logs are not in the unitOptional Stainless Steel / Black Enamel Panel InstallationSlots on Top Panel Black Enamel Panel Installation Log Kit #556-930 contains the following pieces LOG SET InstallationVermiculite NotchNotch in log F Notch in log B2nd Grate Tab Notch in log D Lava Rocks Wall Switch Remote ControlWall Thermostat Installation See Diagram FAN InstallationSlide the the Fan control box Ground LugTabs in Firebox Diagram Flush Glass Door InstallationAdjustable Tension Latch location Diagram Flush Louvers and Flush Panel Installation Optional Finishing Trim InstallationLower PanelDo not tighten the screws leave them loose for the next step Full Screen Arch Door and Frame InstallationOperating Instructions Copy of Lighting Plate Instructions Maintenance Diagram 1 Remove the left and right screws Installing ValveRemoving Valve Main Assembly Parts List2622 Burner Assembly Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

B36X specifications

The Regency B36X is a remarkable gas fireplace that combines elegance with efficiency, designed to seamlessly integrate into any contemporary or traditional living space. This model from Regency is especially popular for its powerful performance and stunning aesthetics, providing both warmth and a focal point for any room.

One of the standout features of the B36X is its impressive heating capabilities. It boasts a heat output of up to 34,000 BTUs, allowing it to efficiently warm spaces up to 1,500 square feet, making it suitable for larger areas. The fireplace utilizes a direct vent system, which ensures that combustion gases are expelled outside while drawing in fresh air for combustion. This contributes to enhanced indoor air quality, as it does not rely on the oxygen from within the home.

In terms of design, the B36X features a sleek, contemporary appearance, characterized by its large viewing area framed by a clean face. Its innovative design maximizes the flame visibility, creating a captivating ambiance. Homeowners can choose from a variety of finishing options, including versatile color choices and customizable trim, allowing the fireplace to match specific interior decor styles.

The fireplace is equipped with advanced technology, including an electronic ignition system that ensures reliable, effortless lighting. For added convenience, optional remote control features enable users to adjust the flame height and temperature with ease. Furthermore, the B36X also supports the installation of a wall thermostat, providing enhanced temperature control and efficiency.

Safety is a crucial element of the Regency B36X. Its glass front is designed with safety in mind, remaining cooler to the touch, which is especially important for households with children or pets. Additionally, the unit is equipped with built-in safety shut-off features that activate in the event of any irregularities in operation.

Energy efficiency is another hallmark of the B36X. Its high efficiency rating ensures that the fuel consumed translates into effective heating, ultimately leading to savings on utility bills. The fireplace meets or exceeds various environmental standards, making it an eco-conscious choice for homeowners looking to reduce their carbon footprint.

In conclusion, the Regency B36X offers a perfect blend of style, functionality, and advanced technology. With its powerful heating capabilities, customizable designs, and enhanced safety features, it stands out as an exceptional choice for anyone looking to enhance their home’s comfort and aesthetics.