Regency B36X Installation, Important Message Save These Instructions, Before YOU Start

Page 7

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The Bellavista™ B36X Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAYAWAYTOAVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9)Wearglovesandsafetyglassesforprotection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by a qualified service person. Aprofessional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

Regency Bellavista™ B36X Gas Fireplace

7

Image 7
Contents Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions DimensionsBefore YOU Start InstallationGeneral Safety Information Important Message Save These InstructionsHeatwave Duct System Optional Installation ChecklistDiagram Locating Your GAS FireplaceClearances Mantel LEG Clearances Mantel ClearancesFraming Framing Dimensions Description B36XImportant Finishing Detail Note FinishingFull Screen Doors Only Screw Position Unit Assembly Prior to Installation Before YOU StartPlates can be Folded out Adjustable Tension Latch location Unit Assembly Prior to InstallationBaffle Plate Diagram Exhaust Assembly Intake Collar Exhaust Assembly Intake Collar DiagramVenting Introduction Minimum Clearance Requirements Exterior Vent Termination RequirementsInstallation Vertical Venting Configurations Approved Venting Configurations6-5/8 Rigid Pipe Cross Reference ChartInstallation Installation Installation Horizontal Terminations Regency Direct Vent Flex System 5 X Rear Vent w/ Horizontal Termination Horizontal Terminations Rigid Pipe Venting Arrangements 5 XHorizontal Termination Top Vent No Vertical RiseHorizontal or Vertical Terminations Rigid Pipe Venting Systems58DVA-WT Allowable Vertical Terminations Venting Arrangements6 5/8 Pipe Venting Arrangements Horizontal Venting with TWO 2 90O Elbows Venting Arrangements Horizontal TerminationVertical Venting with Three 3 90O Elbows Horizontal Venting with Three 3 90O ElbowsAlternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemFor Both Residential & Manufactured Homes Rigid Vent Systems Astrocapxl Unit InstallationGAS Line Installation Unit Installation With Vertical TerminationThis allows for small adjustments T. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationDo not cut the ground terminal off under any circumstances Aeration AdjustmentWiring Diagram Minimum Air Shutter OpeningFor Propane Units and Units Equipped with DC Spark Boxes Wiring Diagram for Gtmf RemoteHeat Defl ector Vent RESTRICTOR, Baffle & Heat Deflector InstallationDiagram 2 Vent restrictor installed on top exhaust assembly Baffl e PlateConversion Kit Contains Qty Description Conversion KIT# 556-969 from NG to LPShut off the gas supply Cap DC Sparker Generator Wires DC Sparker InstallationIgnitor Wire Piezo Sparker Ignitor WireEnsure that the logs are not in the unit Brick Panel InstallationBack Panel Installed Final Brick Panel Installation Handle with care. do not Force Into PositionOptional Stainless Steel / Black Enamel Panel InstallationSlots on Top Panel Black Enamel Panel Installation Notch LOG SET InstallationLog Kit #556-930 contains the following pieces VermiculiteNotch in log F Notch in log B2nd Grate Tab Notch in log D Lava Rocks Wall Switch Remote ControlWall Thermostat Installation Ground Lug FAN InstallationSee Diagram Slide the the Fan control boxTabs in Firebox Diagram Flush Glass Door InstallationAdjustable Tension Latch location Diagram Panel Optional Finishing Trim InstallationFlush Louvers and Flush Panel Installation LowerDo not tighten the screws leave them loose for the next step Full Screen Arch Door and Frame InstallationOperating Instructions Copy of Lighting Plate Instructions Maintenance Diagram 1 Remove the left and right screws Installing ValveRemoving Valve Main Assembly Parts List2622 Burner Assembly Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

B36X specifications

The Regency B36X is a remarkable gas fireplace that combines elegance with efficiency, designed to seamlessly integrate into any contemporary or traditional living space. This model from Regency is especially popular for its powerful performance and stunning aesthetics, providing both warmth and a focal point for any room.

One of the standout features of the B36X is its impressive heating capabilities. It boasts a heat output of up to 34,000 BTUs, allowing it to efficiently warm spaces up to 1,500 square feet, making it suitable for larger areas. The fireplace utilizes a direct vent system, which ensures that combustion gases are expelled outside while drawing in fresh air for combustion. This contributes to enhanced indoor air quality, as it does not rely on the oxygen from within the home.

In terms of design, the B36X features a sleek, contemporary appearance, characterized by its large viewing area framed by a clean face. Its innovative design maximizes the flame visibility, creating a captivating ambiance. Homeowners can choose from a variety of finishing options, including versatile color choices and customizable trim, allowing the fireplace to match specific interior decor styles.

The fireplace is equipped with advanced technology, including an electronic ignition system that ensures reliable, effortless lighting. For added convenience, optional remote control features enable users to adjust the flame height and temperature with ease. Furthermore, the B36X also supports the installation of a wall thermostat, providing enhanced temperature control and efficiency.

Safety is a crucial element of the Regency B36X. Its glass front is designed with safety in mind, remaining cooler to the touch, which is especially important for households with children or pets. Additionally, the unit is equipped with built-in safety shut-off features that activate in the event of any irregularities in operation.

Energy efficiency is another hallmark of the B36X. Its high efficiency rating ensures that the fuel consumed translates into effective heating, ultimately leading to savings on utility bills. The fireplace meets or exceeds various environmental standards, making it an eco-conscious choice for homeowners looking to reduce their carbon footprint.

In conclusion, the Regency B36X offers a perfect blend of style, functionality, and advanced technology. With its powerful heating capabilities, customizable designs, and enhanced safety features, it stands out as an exceptional choice for anyone looking to enhance their home’s comfort and aesthetics.