Regency B36X installation manual Table of Contents

Page 3

TABLE OF CONTENTS

SAFETY LABEL

 

Copy of Safety Decal

4

REQUIREMENTS

 

MA Code - CO Detector

5

DIMENSIONS

 

Unit Dimensions

6

INSTALLATION

 

Important Message

7

Before You Start

7

General Safety Information

7

Installation Checklist

8

Locating Your Gas Fireplace

8

Heatwave Duct System (Optional)

8

Clearances

9

Mantel Leg Clearances

10

Mantel Clearances

10

Framing

11

Finishing

12

Unit Assembly Prior to Installation

13

Top Standoff Assembly

13

Top Facing Support

13

Side Nailing Strips

13

Top Flue Collar Installation

14

Venting Introduction

15

Exterior Vent Termination Requirements

16

Approved Venting Configurations

17

Rigid Pipe Cross Reference Chart

19

4" X 6-5/8"

19

5" X 8"

21

Horizontal Terminations

23

Regency® Direct Vent Flex System (5" x 8")

23

Rigid Pipe venting arrangements (5" x 8")

24

Rigid Pipe Venting Systems

25

HORIZONTAL 5” x 8” rigid rear vent kit

26

for corner installations

26

Venting Arrangements

27

4" x 6 - 5/8" pipe venting arrangements

27

Venting Arrangements Horizontal Termination ....

28

Horizontal Venting with Two (2) 90o Elbows

28

Vertical Venting with Three (3) 90o Elbows

29

Vertical Termination With Co-linear Flex System

30

Venting Arrangement - Vertical Terminations

31

Unit Installation with Horizontal Termination

33

Unit installation with Vertical Termination

34

Gas Line Installation

34

Pilot Adjustment

35

High Elevation

35

Gas Pipe Pressure Testing

35

S.I.T. Valve Description

35

Aeration Adjustment

36

Wiring Diagram

36

Wiring diagram for GTMF remote

37

Vent Restrictor, Baffle & Heat Deflector Installation ....

38

Conversion from NG to LP

39

DC Sparker Installation

41

Brick panel installation

42

Optional Stainless Steel / Black Enamel

43

Panel Installation

43

Log Set installation

45

Optional Wall Thermostat

48

Optional Remote Control

48

Wall Switch (Included)

48

Fan Installation

50

Flush glass door Installation

51

Optional Finishing Trim Installation

52

Flush Louvers and Flush Panel Installation

52

Full Screen Arch Door and Frame Installation

53

OPERATING INSTRUCTIONS

 

Operating Instructions

54

First Fire

54

Lighting Procedure

54

Shutdown Procedure

54

Normal Operating Sounds Of Gas Appliances

54

Copy of Lighting Plate Instructions

55

Maintenance Instructions

56

Log Replacement

56

Thermopile / Thermocouple

56

Door Glass

56

Removing Valve

57

Installing Valve

57

PARTS LIST

 

Main Assembly

58

Burner Assembly

60

WARRANTY

 

The Warranty: Limited Lifetime

64

Regency Bellavista™ B36X Gas Fireplace

3

Image 3
Contents Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions DimensionsBefore YOU Start InstallationGeneral Safety Information Important Message Save These InstructionsHeatwave Duct System Optional Installation ChecklistDiagram Locating Your GAS FireplaceClearances Mantel LEG Clearances Mantel ClearancesFraming Framing Dimensions Description B36XFinishing Important Finishing Detail NoteFull Screen Doors Only Unit Assembly Prior to Installation Before YOU Start Screw PositionPlates can be Folded out Unit Assembly Prior to Installation Adjustable Tension Latch locationBaffle Plate Exhaust Assembly Intake Collar Diagram Diagram Exhaust Assembly Intake CollarVenting Introduction Minimum Clearance Requirements Exterior Vent Termination RequirementsInstallation Vertical Venting Configurations Approved Venting Configurations6-5/8 Rigid Pipe Cross Reference ChartInstallation Installation Installation Horizontal Terminations Regency Direct Vent Flex System 5 X Rear Vent w/ Horizontal Termination Horizontal Terminations Rigid Pipe Venting Arrangements 5 XHorizontal Termination Top Vent No Vertical RiseHorizontal or Vertical Terminations Rigid Pipe Venting Systems58DVA-WT Venting Arrangements Allowable Vertical Terminations6 5/8 Pipe Venting Arrangements Horizontal Venting with TWO 2 90O Elbows Venting Arrangements Horizontal TerminationVertical Venting with Three 3 90O Elbows Horizontal Venting with Three 3 90O ElbowsAlternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemFor Both Residential & Manufactured Homes Rigid Vent Systems Astrocapxl Unit InstallationUnit Installation With Vertical Termination GAS Line InstallationThis allows for small adjustments T. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationDo not cut the ground terminal off under any circumstances Aeration AdjustmentWiring Diagram Minimum Air Shutter OpeningFor Propane Units and Units Equipped with DC Spark Boxes Wiring Diagram for Gtmf RemoteHeat Defl ector Vent RESTRICTOR, Baffle & Heat Deflector InstallationDiagram 2 Vent restrictor installed on top exhaust assembly Baffl e PlateConversion KIT# 556-969 from NG to LP Conversion Kit Contains Qty DescriptionShut off the gas supply Cap DC Sparker Generator Wires DC Sparker InstallationIgnitor Wire Piezo Sparker Ignitor WireEnsure that the logs are not in the unit Brick Panel InstallationBack Panel Installed Final Brick Panel Installation Handle with care. do not Force Into PositionPanel Installation Optional Stainless Steel / Black EnamelSlots on Top Panel Black Enamel Panel Installation Notch LOG SET InstallationLog Kit #556-930 contains the following pieces VermiculiteNotch in log B Notch in log F2nd Grate Tab Notch in log D Lava Rocks Remote Control Wall SwitchWall Thermostat Installation Ground Lug FAN InstallationSee Diagram Slide the the Fan control boxFlush Glass Door Installation Tabs in Firebox DiagramAdjustable Tension Latch location Diagram Panel Optional Finishing Trim InstallationFlush Louvers and Flush Panel Installation LowerDo not tighten the screws leave them loose for the next step Full Screen Arch Door and Frame InstallationOperating Instructions Copy of Lighting Plate Instructions Maintenance Installing Valve Diagram 1 Remove the left and right screwsRemoving Valve Main Assembly Parts List2622 Burner Assembly Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

B36X specifications

The Regency B36X is a remarkable gas fireplace that combines elegance with efficiency, designed to seamlessly integrate into any contemporary or traditional living space. This model from Regency is especially popular for its powerful performance and stunning aesthetics, providing both warmth and a focal point for any room.

One of the standout features of the B36X is its impressive heating capabilities. It boasts a heat output of up to 34,000 BTUs, allowing it to efficiently warm spaces up to 1,500 square feet, making it suitable for larger areas. The fireplace utilizes a direct vent system, which ensures that combustion gases are expelled outside while drawing in fresh air for combustion. This contributes to enhanced indoor air quality, as it does not rely on the oxygen from within the home.

In terms of design, the B36X features a sleek, contemporary appearance, characterized by its large viewing area framed by a clean face. Its innovative design maximizes the flame visibility, creating a captivating ambiance. Homeowners can choose from a variety of finishing options, including versatile color choices and customizable trim, allowing the fireplace to match specific interior decor styles.

The fireplace is equipped with advanced technology, including an electronic ignition system that ensures reliable, effortless lighting. For added convenience, optional remote control features enable users to adjust the flame height and temperature with ease. Furthermore, the B36X also supports the installation of a wall thermostat, providing enhanced temperature control and efficiency.

Safety is a crucial element of the Regency B36X. Its glass front is designed with safety in mind, remaining cooler to the touch, which is especially important for households with children or pets. Additionally, the unit is equipped with built-in safety shut-off features that activate in the event of any irregularities in operation.

Energy efficiency is another hallmark of the B36X. Its high efficiency rating ensures that the fuel consumed translates into effective heating, ultimately leading to savings on utility bills. The fireplace meets or exceeds various environmental standards, making it an eco-conscious choice for homeowners looking to reduce their carbon footprint.

In conclusion, the Regency B36X offers a perfect blend of style, functionality, and advanced technology. With its powerful heating capabilities, customizable designs, and enhanced safety features, it stands out as an exceptional choice for anyone looking to enhance their home’s comfort and aesthetics.