Heat Deflector

INSTALLATION

UNIT ASSEMBLY PRIOR TO INSTALLATION

TOP FLUE COLLAR INSTALLATION

Note: This conversion must be done prior to the unit being placed in position.

The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.

Top Collar Assembly Kit

1Intake Collar Assembly with Gasket

1Intake Collar Plate with Gasket

1Top/Rear Exhaust Assembly with Gasket

1Heat Deflector

1Baffle Plate

291/4" x 1/2" Screws (4 spares)

1

Restrictor

1

Intake Collar Gasket (spare)

1

Exhaust Assembly Gasket (spare)

Exhaust Assembly

Intake Collar Plate

Intake Collar Assembly

w/ gasket

w/gasket

w/gasket

1. Remove the door assembly by releasing the adjustable latches and lifting up off the door frame assembly.

Adjustable Tension

Latch location

2)From inside the firebox, remove the top heat deflector by removing 2 - 1/4" x 1/2" screws.

Diagram 2

3)From inside the firebox, remove the baffle plate by removing 4 - 1/4"

x1/2 " screws. See Diagram 3

Baffle Plate

Diagram 3

 

Diagram 1

4)From the inside of the firebox, remove the exhaust assembly by removing the 8 - 1/4" x 1/2" screws. See Diagram 4.

Diagram 4

14

Regency Bellavista™ B36X Gas Fireplace

Image 14
Contents Regency Bellavista B36X Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Regency Bellavista B36X Gas FireplaceTable of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorDimensions Unit DimensionsImportant Message Save These Instructions InstallationGeneral Safety Information Before YOU StartLocating Your GAS Fireplace Installation ChecklistDiagram Heatwave Duct System OptionalClearances Mantel Clearances Mantel LEG ClearancesFraming Dimensions Description B36X FramingFull Screen Doors Only FinishingImportant Finishing Detail Note Plates can be Folded out Unit Assembly Prior to Installation Before YOU StartScrew Position Baffle Plate Unit Assembly Prior to InstallationAdjustable Tension Latch location Venting Introduction Exhaust Assembly Intake Collar DiagramDiagram Exhaust Assembly Intake Collar Exterior Vent Termination Requirements Minimum Clearance RequirementsInstallation Approved Venting Configurations Vertical Venting ConfigurationsRigid Pipe Cross Reference Chart 6-5/8Installation Installation Installation Horizontal Terminations Regency Direct Vent Flex System 5 X Top Vent No Vertical Rise Horizontal Terminations Rigid Pipe Venting Arrangements 5 XHorizontal Termination Rear Vent w/ Horizontal TerminationRigid Pipe Venting Systems Horizontal or Vertical Terminations58DVA-WT 6 5/8 Pipe Venting Arrangements Venting ArrangementsAllowable Vertical Terminations Venting Arrangements Horizontal Termination Horizontal Venting with TWO 2 90O ElbowsHorizontal Venting with Three 3 90O Elbows Vertical Venting with Three 3 90O ElbowsVertical Termination With CO-LINEAR Flex System Alternate Approved CapsFor Both Residential & Manufactured Homes Rigid Vent Systems Unit Installation AstrocapxlThis allows for small adjustments Unit Installation With Vertical TerminationGAS Line Installation High Elevation Pilot AdjustmentGAS Pipe Pressure Testing T. Valve DescriptionMinimum Air Shutter Opening Aeration AdjustmentWiring Diagram Do not cut the ground terminal off under any circumstancesWiring Diagram for Gtmf Remote For Propane Units and Units Equipped with DC Spark BoxesBaffl e Plate Vent RESTRICTOR, Baffle & Heat Deflector InstallationDiagram 2 Vent restrictor installed on top exhaust assembly Heat Defl ectorShut off the gas supply Conversion KIT# 556-969 from NG to LPConversion Kit Contains Qty Description Cap Sparker Ignitor Wire DC Sparker InstallationIgnitor Wire Piezo DC Sparker Generator WiresHandle with care. do not Force Into Position Brick Panel InstallationBack Panel Installed Final Brick Panel Installation Ensure that the logs are not in the unitSlots on Top Panel Panel InstallationOptional Stainless Steel / Black Enamel Black Enamel Panel Installation Vermiculite LOG SET InstallationLog Kit #556-930 contains the following pieces Notch2nd Grate Tab Notch in log BNotch in log F Notch in log D Lava Rocks Wall Thermostat Remote ControlWall Switch Installation Slide the the Fan control box FAN InstallationSee Diagram Ground LugAdjustable Tension Latch location Diagram Flush Glass Door InstallationTabs in Firebox Diagram Lower Optional Finishing Trim InstallationFlush Louvers and Flush Panel Installation PanelFull Screen Arch Door and Frame Installation Do not tighten the screws leave them loose for the next stepOperating Instructions Copy of Lighting Plate Instructions Maintenance Removing Valve Installing ValveDiagram 1 Remove the left and right screws Parts List Main Assembly2622 Burner Assembly Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

B36X specifications

The Regency B36X is a remarkable gas fireplace that combines elegance with efficiency, designed to seamlessly integrate into any contemporary or traditional living space. This model from Regency is especially popular for its powerful performance and stunning aesthetics, providing both warmth and a focal point for any room.

One of the standout features of the B36X is its impressive heating capabilities. It boasts a heat output of up to 34,000 BTUs, allowing it to efficiently warm spaces up to 1,500 square feet, making it suitable for larger areas. The fireplace utilizes a direct vent system, which ensures that combustion gases are expelled outside while drawing in fresh air for combustion. This contributes to enhanced indoor air quality, as it does not rely on the oxygen from within the home.

In terms of design, the B36X features a sleek, contemporary appearance, characterized by its large viewing area framed by a clean face. Its innovative design maximizes the flame visibility, creating a captivating ambiance. Homeowners can choose from a variety of finishing options, including versatile color choices and customizable trim, allowing the fireplace to match specific interior decor styles.

The fireplace is equipped with advanced technology, including an electronic ignition system that ensures reliable, effortless lighting. For added convenience, optional remote control features enable users to adjust the flame height and temperature with ease. Furthermore, the B36X also supports the installation of a wall thermostat, providing enhanced temperature control and efficiency.

Safety is a crucial element of the Regency B36X. Its glass front is designed with safety in mind, remaining cooler to the touch, which is especially important for households with children or pets. Additionally, the unit is equipped with built-in safety shut-off features that activate in the event of any irregularities in operation.

Energy efficiency is another hallmark of the B36X. Its high efficiency rating ensures that the fuel consumed translates into effective heating, ultimately leading to savings on utility bills. The fireplace meets or exceeds various environmental standards, making it an eco-conscious choice for homeowners looking to reduce their carbon footprint.

In conclusion, the Regency B36X offers a perfect blend of style, functionality, and advanced technology. With its powerful heating capabilities, customizable designs, and enhanced safety features, it stands out as an exceptional choice for anyone looking to enhance their home’s comfort and aesthetics.