Regency B36X Installation Checklist, Locating Your GAS Fireplace, Heatwave Duct System Optional

Page 8

INSTALLATION

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location (Refer to "Locating Your Gas fireplace" section)

b)Clearances to Combustibles (Refer to "Clearances" section)

c)MantelClearances(Referto"Combustible Mantel Clearances" section)

d)Framing&FinishingRequirements(Refer to "Framing & Finishing" section)

e)Venting Requirements (Refer to "Venting" section)

2)Assemble Top Standoffs and Top Facing Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation" Section). NOTE: Must be done before installing unit into place.

3)Install vent (Refer to "Venting" sections).

4)Make gas and electrical connections. Test the pilot. Must be as per diagram (Refer to "Pilot Adjustment " section).

Convert to propane if desired (Refer to "Gas Line Installation" and "Conversion Kit from NG to LPG" sections).

5)Install standard and optional features. Refer to the following sections:

a.LP Conversion Kit (Optional)

b.Brick Panels (Optional)

c.Log Set Installation

d.Standard Flush Door

e.Full Screen Door (Optional)

f.Flush Panel/Louver (Optional)

g.Remote control,Wall Switch or Thermostat (Optional)

h.Fan Installation (Optional)

6)Final check.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fireplace, ensure that the clearances are met.

2)The appliance must be installed on a flat, solid, continuous surface For example a wood, metal or concrete floor or in a raised (on the wall) application. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

3)The B36X Bellavista™ Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.

Diagram 1

A)Flat on Wall

B)Flat on Wall Corner

C)Recessed into Wall/Alcove

D)Corner

4)This appliance is Listed for bedroom installations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

5)The B36X Gas Fireplace are approved for alcove installations, see "Clearances" section for details.

6)We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For vent terminations refer to "Exterior Vent Termination Locations" section.

HEATWAVE

DUCT SYSTEM

(OPTIONAL)

#946-556

The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fireplace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.

8

Regency Bellavista™ B36X Gas Fireplace

Image 8
Contents Regency Bellavista B36X Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Regency Bellavista B36X Gas FireplaceTable of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorDimensions Unit DimensionsInstallation General Safety InformationImportant Message Save These Instructions Before YOU StartInstallation Checklist DiagramLocating Your GAS Fireplace Heatwave Duct System OptionalClearances Mantel Clearances Mantel LEG ClearancesFraming Dimensions Description B36X FramingFull Screen Doors Only FinishingImportant Finishing Detail Note Plates can be Folded out Unit Assembly Prior to Installation Before YOU StartScrew Position Baffle Plate Unit Assembly Prior to InstallationAdjustable Tension Latch location Venting Introduction Exhaust Assembly Intake Collar DiagramDiagram Exhaust Assembly Intake Collar Exterior Vent Termination Requirements Minimum Clearance RequirementsInstallation Approved Venting Configurations Vertical Venting ConfigurationsRigid Pipe Cross Reference Chart 6-5/8Installation Installation Installation Horizontal Terminations Regency Direct Vent Flex System 5 X Horizontal Terminations Rigid Pipe Venting Arrangements 5 X Horizontal TerminationTop Vent No Vertical Rise Rear Vent w/ Horizontal TerminationRigid Pipe Venting Systems Horizontal or Vertical Terminations58DVA-WT 6 5/8 Pipe Venting Arrangements Venting ArrangementsAllowable Vertical Terminations Venting Arrangements Horizontal Termination Horizontal Venting with TWO 2 90O ElbowsHorizontal Venting with Three 3 90O Elbows Vertical Venting with Three 3 90O ElbowsVertical Termination With CO-LINEAR Flex System Alternate Approved CapsFor Both Residential & Manufactured Homes Rigid Vent Systems Unit Installation AstrocapxlThis allows for small adjustments Unit Installation With Vertical TerminationGAS Line Installation Pilot Adjustment GAS Pipe Pressure TestingHigh Elevation T. Valve DescriptionAeration Adjustment Wiring DiagramMinimum Air Shutter Opening Do not cut the ground terminal off under any circumstancesWiring Diagram for Gtmf Remote For Propane Units and Units Equipped with DC Spark BoxesVent RESTRICTOR, Baffle & Heat Deflector Installation Diagram 2 Vent restrictor installed on top exhaust assemblyBaffl e Plate Heat Defl ectorShut off the gas supply Conversion KIT# 556-969 from NG to LPConversion Kit Contains Qty Description Cap DC Sparker Installation Ignitor Wire PiezoSparker Ignitor Wire DC Sparker Generator WiresBrick Panel Installation Back Panel Installed Final Brick Panel InstallationHandle with care. do not Force Into Position Ensure that the logs are not in the unitSlots on Top Panel Panel InstallationOptional Stainless Steel / Black Enamel Black Enamel Panel Installation LOG SET Installation Log Kit #556-930 contains the following piecesVermiculite Notch2nd Grate Tab Notch in log BNotch in log F Notch in log D Lava Rocks Wall Thermostat Remote ControlWall Switch Installation FAN Installation See DiagramSlide the the Fan control box Ground LugAdjustable Tension Latch location Diagram Flush Glass Door InstallationTabs in Firebox Diagram Optional Finishing Trim Installation Flush Louvers and Flush Panel InstallationLower PanelFull Screen Arch Door and Frame Installation Do not tighten the screws leave them loose for the next stepOperating Instructions Copy of Lighting Plate Instructions Maintenance Removing Valve Installing ValveDiagram 1 Remove the left and right screws Parts List Main Assembly2622 Burner Assembly Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

B36X specifications

The Regency B36X is a remarkable gas fireplace that combines elegance with efficiency, designed to seamlessly integrate into any contemporary or traditional living space. This model from Regency is especially popular for its powerful performance and stunning aesthetics, providing both warmth and a focal point for any room.

One of the standout features of the B36X is its impressive heating capabilities. It boasts a heat output of up to 34,000 BTUs, allowing it to efficiently warm spaces up to 1,500 square feet, making it suitable for larger areas. The fireplace utilizes a direct vent system, which ensures that combustion gases are expelled outside while drawing in fresh air for combustion. This contributes to enhanced indoor air quality, as it does not rely on the oxygen from within the home.

In terms of design, the B36X features a sleek, contemporary appearance, characterized by its large viewing area framed by a clean face. Its innovative design maximizes the flame visibility, creating a captivating ambiance. Homeowners can choose from a variety of finishing options, including versatile color choices and customizable trim, allowing the fireplace to match specific interior decor styles.

The fireplace is equipped with advanced technology, including an electronic ignition system that ensures reliable, effortless lighting. For added convenience, optional remote control features enable users to adjust the flame height and temperature with ease. Furthermore, the B36X also supports the installation of a wall thermostat, providing enhanced temperature control and efficiency.

Safety is a crucial element of the Regency B36X. Its glass front is designed with safety in mind, remaining cooler to the touch, which is especially important for households with children or pets. Additionally, the unit is equipped with built-in safety shut-off features that activate in the event of any irregularities in operation.

Energy efficiency is another hallmark of the B36X. Its high efficiency rating ensures that the fuel consumed translates into effective heating, ultimately leading to savings on utility bills. The fireplace meets or exceeds various environmental standards, making it an eco-conscious choice for homeowners looking to reduce their carbon footprint.

In conclusion, the Regency B36X offers a perfect blend of style, functionality, and advanced technology. With its powerful heating capabilities, customizable designs, and enhanced safety features, it stands out as an exceptional choice for anyone looking to enhance their home’s comfort and aesthetics.