UNIT INSTALLATION WITH HORIZONTAL TERMINATION USING 5" X 8" VENTING

(Rigid Vent Systems)

Note: 5" x 8" venting is limited to vent configurations found on page 17 of this manual.

A top clearance of 2"(51mm) and side & bottom clearance of 1-1/2"(38mm) must be maintained; except when passing through a wall, ceiling, or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1-1/2" (38mm). We rec- ommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.

Install the vent system according to the manufacturer's instructions included with the components.

connection. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.

Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.

6)Mark the wall for a 11" x 11" (279mm x 279mm) square hole. The center of the square hole should line up with the center- line of the horizontal pipe. Cut and frame the 11 inch (279mm) square hole in the exterior wall where the vent will be terminated. See diagram 2 for center line requirements.

7)Ensure that the pipe clearances to combustible materials are maintained (Diagram 5). Install the termination cap.

Note: If installing termination on a vinyl siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.

1)Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.

2)Direct Vent pipe and fittings are designed with special twist-lock connections to connect the venting system to the appliance flue outlet. A twist-lock appliance adaptor is required.

3)In conjunction with the Simpson Direct Vent Pro system, install the adaptor after the unit is set in its desired location. Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar. Slip the adapter over the existing inner and outer flue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier).

4)Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips.

5)Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection.

Note: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe

Diagram 2

If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable.

Note:

a)The horizontal run of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.

b)The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations" section for more details.

Diagram 5

The four wood screws provided should be re- placed with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

8)Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble over the vent pipe. The wall thimble is required for all horizontal terminations.

9)Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap.

10)Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7).

Diagram 1

Diagram 7

32

Regency Bellavista™ B36X Gas Fireplace

Image 32
Contents Regency Bellavista B36X Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Regency Bellavista B36X Gas FireplaceTable of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorDimensions Unit DimensionsInstallation General Safety InformationImportant Message Save These Instructions Before YOU StartInstallation Checklist DiagramLocating Your GAS Fireplace Heatwave Duct System OptionalClearances Mantel Clearances Mantel LEG ClearancesFraming Dimensions Description B36X FramingFull Screen Doors Only FinishingImportant Finishing Detail Note Plates can be Folded out Unit Assembly Prior to Installation Before YOU StartScrew Position Baffle Plate Unit Assembly Prior to InstallationAdjustable Tension Latch location Venting Introduction Exhaust Assembly Intake Collar DiagramDiagram Exhaust Assembly Intake Collar Exterior Vent Termination Requirements Minimum Clearance RequirementsInstallation Approved Venting Configurations Vertical Venting ConfigurationsRigid Pipe Cross Reference Chart 6-5/8Installation Installation Installation Horizontal Terminations Regency Direct Vent Flex System 5 X Horizontal Terminations Rigid Pipe Venting Arrangements 5 X Horizontal TerminationTop Vent No Vertical Rise Rear Vent w/ Horizontal TerminationRigid Pipe Venting Systems Horizontal or Vertical Terminations58DVA-WT 6 5/8 Pipe Venting Arrangements Venting ArrangementsAllowable Vertical Terminations Venting Arrangements Horizontal Termination Horizontal Venting with TWO 2 90O ElbowsHorizontal Venting with Three 3 90O Elbows Vertical Venting with Three 3 90O ElbowsVertical Termination With CO-LINEAR Flex System Alternate Approved CapsFor Both Residential & Manufactured Homes Rigid Vent Systems Unit Installation AstrocapxlThis allows for small adjustments Unit Installation With Vertical TerminationGAS Line Installation Pilot Adjustment GAS Pipe Pressure TestingHigh Elevation T. Valve DescriptionAeration Adjustment Wiring DiagramMinimum Air Shutter Opening Do not cut the ground terminal off under any circumstancesWiring Diagram for Gtmf Remote For Propane Units and Units Equipped with DC Spark BoxesVent RESTRICTOR, Baffle & Heat Deflector Installation Diagram 2 Vent restrictor installed on top exhaust assemblyBaffl e Plate Heat Defl ectorShut off the gas supply Conversion KIT# 556-969 from NG to LPConversion Kit Contains Qty Description Cap DC Sparker Installation Ignitor Wire PiezoSparker Ignitor Wire DC Sparker Generator WiresBrick Panel Installation Back Panel Installed Final Brick Panel InstallationHandle with care. do not Force Into Position Ensure that the logs are not in the unitSlots on Top Panel Panel InstallationOptional Stainless Steel / Black Enamel Black Enamel Panel Installation LOG SET Installation Log Kit #556-930 contains the following piecesVermiculite Notch2nd Grate Tab Notch in log BNotch in log F Notch in log D Lava Rocks Wall Thermostat Remote ControlWall Switch Installation FAN Installation See DiagramSlide the the Fan control box Ground LugAdjustable Tension Latch location Diagram Flush Glass Door InstallationTabs in Firebox Diagram Optional Finishing Trim Installation Flush Louvers and Flush Panel InstallationLower PanelFull Screen Arch Door and Frame Installation Do not tighten the screws leave them loose for the next stepOperating Instructions Copy of Lighting Plate Instructions Maintenance Removing Valve Installing ValveDiagram 1 Remove the left and right screws Parts List Main Assembly2622 Burner Assembly Regency Bellavista B36X Gas Fireplace Regency Bellavista B36X Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

B36X specifications

The Regency B36X is a remarkable gas fireplace that combines elegance with efficiency, designed to seamlessly integrate into any contemporary or traditional living space. This model from Regency is especially popular for its powerful performance and stunning aesthetics, providing both warmth and a focal point for any room.

One of the standout features of the B36X is its impressive heating capabilities. It boasts a heat output of up to 34,000 BTUs, allowing it to efficiently warm spaces up to 1,500 square feet, making it suitable for larger areas. The fireplace utilizes a direct vent system, which ensures that combustion gases are expelled outside while drawing in fresh air for combustion. This contributes to enhanced indoor air quality, as it does not rely on the oxygen from within the home.

In terms of design, the B36X features a sleek, contemporary appearance, characterized by its large viewing area framed by a clean face. Its innovative design maximizes the flame visibility, creating a captivating ambiance. Homeowners can choose from a variety of finishing options, including versatile color choices and customizable trim, allowing the fireplace to match specific interior decor styles.

The fireplace is equipped with advanced technology, including an electronic ignition system that ensures reliable, effortless lighting. For added convenience, optional remote control features enable users to adjust the flame height and temperature with ease. Furthermore, the B36X also supports the installation of a wall thermostat, providing enhanced temperature control and efficiency.

Safety is a crucial element of the Regency B36X. Its glass front is designed with safety in mind, remaining cooler to the touch, which is especially important for households with children or pets. Additionally, the unit is equipped with built-in safety shut-off features that activate in the event of any irregularities in operation.

Energy efficiency is another hallmark of the B36X. Its high efficiency rating ensures that the fuel consumed translates into effective heating, ultimately leading to savings on utility bills. The fireplace meets or exceeds various environmental standards, making it an eco-conscious choice for homeowners looking to reduce their carbon footprint.

In conclusion, the Regency B36X offers a perfect blend of style, functionality, and advanced technology. With its powerful heating capabilities, customizable designs, and enhanced safety features, it stands out as an exceptional choice for anyone looking to enhance their home’s comfort and aesthetics.