Regency E21-LP3, E21-NG3 Valve Description, GAS Insert Aeration System, Test for Flue Spillage

Page 13

INSTALLATION

VALVE DESCRIPTION

1)Gas on/off knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection

5)Main Operator

6)Outlet Pressure Tap (Manifold Pressure)

7)Inlet Pressure Tap (Supply Pressure)

8)Pilot Outlet

9)Main Gas Outlet

10)Flange Securing Screw Holes

11)Alternative TC Connection Point

12)Thermoelectric Unit

13)Additional Valve Mounting Hole

GAS INSERT

AERATION SYSTEM

The aeration adjustment rod is attached to the air shutter which is located just above the orifice bracket. The rod is used to adjust the aeration on the main burner without having to take the appliance apart.

The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude.

Natural Gas:

1/8" open

Propane:

5/16" open

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

Note: Aeration Adjustment should only be performedbyanauthorizedRegency® Installer at the time of installation or service.

TEST FOR

FLUE SPILLAGE

A " spillage" test must be made before the installed unit is left with the customer. Follow the procedure below:

1)Close all external doors and windows in the house.

2)Light the unit and set controls to maximum. Turn fan to OFF on unit.

3)After five minutes, test that there is a “pull” on the flue by placing a smoking match, cigarette or similar device which gives off smoke, in front of the upper part of the louver. To ensure a valid test, place

a scrap piece of sheet metal (or other noncombustible material) in the upper louver, this will prevent the natural convection of the unit from interfering with the test.

Note: The smoke should be drawn into the louver. If the smoke is still not drawn in, turn the unit off and check for the cause of the lack of draft. If necessary, seek expert advice.

OPTIONAL

BRICK PANEL

1)Unwrap the brick pattern panels from the protective wrapping.

2)With the glass removed, position the back panel first (see diagram for correct positioning), then the two side panels. Slide the side brick panel into place from the front of the firebox, there is a tab at the top of the unit to hold the side panels in place.

3)The brick panels should be tight against the firebox sides and back. The side panels should be flush with the glass.

Note: Use caution when sliding side panels in as they can easily be scratched by the brick panel tabs.

Regency® E21-3 Gas Fireplace Insert

13

Image 13
Contents E21 Gas Insert Congratulations Table of Contents Duplicate Serial No Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationImportant Message Save These Instructions Before YOU StartMinimum Fireplace Clearances Installation ChecklistCombustible board Clearances to CombustiblesHigh Elevation GAS ConnectionLug Detail Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Flue Connector InstallationOffset Flue Adaptor GAS Pipe Pressure TestingVenting GAS Insert Aeration System Valve DescriptionTest for Flue Spillage Optional Brick Panel27-23 27-30 27-27 27-24 27-28 27-25 LOG SET Installation27-26 27-2327-27 27-25 27-23 27-24 27-26 27-2527-27 27-26 27-30 27-23 27-29 27-2827-27 27-29 27-24 27-26 27-27 27-23 27-24 27-30 27-29 27-26 27-25 Ensure not to cover any burner portsDiagram Faceplate & Trim InstallationUse of substitute glass will Void all product warranties Flush Glass Flush LouversBAY Louvers Optional BAY FrontDC Sparker Kit Contains LPG Conversion Kit Contains Qty DescriptionQty Description Installation of the DC Sparker Heat Shield Full Screen Doors Screen Door Hinge Location Bottom Frame Wall Thermostat Remote Control Wall SwitchOperating Instructions Copy of Lighting Plate Instructions Maintenance Removing Valve Assembly Door Glass ReplacementDisconnect the power Removing the FANMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay DoorFaceplate Assembly Conditions WarrantyInstaller Please complete the following information