Regency E21-LP3, E21-NG3 installation manual Operating Instructions

Page 27

OPERATING INSTRUCTIONS

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the unit is not the responsibility of the manufacturer and will not be covered by the warranty.

6)Verify log placement. If the pilot cannot be seen when lighting the unit - the logs or the embers have been incorrectly positioned.

7)The unit should never be turned off and on again without a minimum of a 60 second wait.

8)When lighting the appliance, the inside of the glass may fog up, this will burn off after a few minutes of operation.

Gas In

 

TH

 

Shut Off

TP

 

TPTH

Gas Out

 

Hi-Low

 

 

 

Pilot Adjust

 

 

7)Turn gas control knob counter clockwise to "ON".

8)Use the rocker switch to operate main burner.

9)Rotate the variable flame control to adjust the flame height higher or lower.

10)Close the bottom louver assembly.

SHUTDOWN

PROCEDURE

1)

Use the rocker switch to turn off the main

 

burner.

2)

Open the bottom louver assembly.

3)

Push in the gas control knob slightly and

 

turn clockwise to "OFF". Do not force.

4)

Disconnect all electric power and gas

 

to the appliance if service is to be

 

performed.

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed through the following check list.

1)Read and understand these Instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass door is in place. Never operate the appliance with the door glass removed.

5)Verify that all venting and the cap is unobstructed.

LIGHTING PROCEDURE

NOTE: For all propane units and units equipped with electric spark boxes, see "Copy of Lighting Plate Instruc- tions" section for more details.

IMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Open the bottom louver assembly

2)If the control knob is in the "OFF" position proceed to Step 5.

3)Push in gas control knob slightly and turn clockwise to "OFF". Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.

4)Wait five minutes to allow gas, that may have accumulated in the main burner compartment, to escape. If you do smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step.

5)Turn the gas control counter clockwise to "PILOT".

6)Push in control knob all the way and hold in. Continually push and release the black button on spark igniter until pilot lights. Continue to hold the control knob in for approximately one minute, then release the gas control knob. The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob.

FIRST FIRE

The first fire in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on. When first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

Do not use abrasive cleaners on the glass.

Note: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

Regency® E21-3 Gas Fireplace Insert

27

Image 27
Contents E21 Gas Insert Congratulations Table of Contents Duplicate Serial No Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationGeneral Safety Information Important Message Save These InstructionsMinimum Fireplace Clearances Installation ChecklistCombustible board Clearances to CombustiblesHigh Elevation GAS ConnectionLug Detail Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Flue Connector InstallationGAS Pipe Pressure Testing Offset Flue AdaptorVenting Optional Brick Panel Valve DescriptionGAS Insert Aeration System Test for Flue Spillage27-23 LOG SET Installation27-23 27-30 27-27 27-24 27-28 27-25 27-2627-24 27-26 27-25 27-27 27-25 27-2327-27 27-26 27-29 27-28 27-30 27-2327-27 27-29 27-24 27-26 27-27 27-23 27-24 27-30 27-29 27-26 27-25 Ensure not to cover any burner portsDiagram Faceplate & Trim InstallationUse of substitute glass will Void all product warranties Flush Glass Flush LouversBAY Louvers Optional BAY FrontLPG Conversion Kit Contains Qty Description DC Sparker Kit ContainsQty Description Installation of the DC Sparker Heat Shield Full Screen Doors Screen Door Hinge Location Bottom Frame Wall Thermostat Remote Control Wall SwitchOperating Instructions Copy of Lighting Plate Instructions Maintenance Removing the FAN Door Glass ReplacementRemoving Valve Assembly Disconnect the powerMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay DoorFaceplate Assembly Conditions WarrantyInstaller Please complete the following information