INSTALLATION

POLICY FOR SOLID FUEL BURNING & FACTORY BUILT FIREPLACES

The Regency® E21 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial and local building codes and is constructed of non- combustible materials.

1)Installer must mechanically attach the sup- plied label to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.

"WARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction."

2)Do not cut any sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed.

3)If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1-1/2" (37.5mm) or less may be drilled though the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with a non-combustible insulation after the gas supply line has been installed.

4)The fireplace flue damper can be fully blocked open or removed for installation of the gas fireplace insert.

5)The fireplace and fireplace chimney must be clean and in good working order and constructed of non-combustible materials.

6)The chimney cleanouts must fit properly.

7)Refractory (firebricks), glass doors, screen rails, screen mesh and log grates can be removed from the fireplace before installing the gas fireplace insert.

8)Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. If any part is removed it must not weaken the structural integrity of the factory built.

9)Trim panels or surrounds shall not seal ventilation openings in the fireplace.

INSTALLATION

CHECKLIST

1)Locate your appliance. Refer to the "Clear- ances to Combustibles" and "Minimum Fireplace Clearances" sections.

2)Make gas and electrical connections. Refer to the "Gas Connection" section.

Test the pilot. Must be as per diagram in the "Valve Description" section.

3)Install Flue Connector. Refer to the "Flue Connector Installation" section.

4)Install vent. Refer to the "Venting" section.

5)Test Gas pressure. Refer to the "Gas Pipe Pressure Testing" section.

Check aeration. Refer to the "Gas Insert Aeration System" section.

6)Test for flue spillage. Refer to the "Test for Flue Spillage" section.

7)Install standard and optional features. Refer to the following sections where applicable:

a.Brick Panel

b.Faceplate & Trim

c.Flush Glass

d.Flush Louver

e.Bay Front

f.Full Screen Doors

g.Remote Control

h.Wall Switch

i.Wall Thermostat

8)Final check. Refer to the "Final Check" section.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

3)Ensure that the appliance is venting correctly.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MINIMUM FIREPLACE

CLEARANCES

Diagram shows the minimum fireplace opening required to be able to install the Regency® gas fireplace insert.

Note: If you are installing the Molded Faceplate, the minimum fireplace dimensions are as follows:

Width (at front):

29-1/8" (740mm)

Depth:

15" (381mm)

Height:

18-5/8" (473mm)

Regency® E21-3 Gas Fireplace Insert

7

Image 7
Contents E21 Gas Insert Congratulations Table of Contents Duplicate Serial No Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationGeneral Safety Information Important Message Save These InstructionsMinimum Fireplace Clearances Installation ChecklistCombustible board Clearances to CombustiblesHigh Elevation GAS ConnectionLug Detail Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Flue Connector InstallationOffset Flue Adaptor GAS Pipe Pressure TestingVenting Optional Brick Panel Valve DescriptionGAS Insert Aeration System Test for Flue Spillage27-23 LOG SET Installation27-23 27-30 27-27 27-24 27-28 27-25 27-2627-27 27-25 27-23 27-24 27-26 27-2527-27 27-26 27-30 27-23 27-29 27-2827-27 27-29 27-24 27-26 27-27 27-23 27-24 27-30 27-29 27-26 27-25 Ensure not to cover any burner portsDiagram Faceplate & Trim InstallationUse of substitute glass will Void all product warranties Flush Glass Flush LouversBAY Louvers Optional BAY FrontDC Sparker Kit Contains LPG Conversion Kit Contains Qty DescriptionQty Description Installation of the DC Sparker Heat Shield Full Screen Doors Screen Door Hinge Location Bottom Frame Wall Thermostat Remote Control Wall SwitchOperating Instructions Copy of Lighting Plate Instructions Maintenance Removing the FAN Door Glass ReplacementRemoving Valve Assembly Disconnect the powerMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay DoorFaceplate Assembly Conditions WarrantyInstaller Please complete the following information