Page 23

INSTALLATION

29)Install the 1/2" bushing to the heat shield.

30)Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield.

Heat Shield

32)Connect the ground wire to the DC Sparker mounting bracket.

33)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

35a) Remove the bottom louver (if in place) by unscrewing the four screws located on the hinges.

35b) Location to mount the DC Sparker.

31)Plug the DC spark generator wires to the DC Sparker.

Battery

Compartment

34)Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit.

36)Tie up the loose wire with the wire clip.

37)Check for gas leaks.

38)Check inlet and outlet pressures.

39)Check operation of fl ame control.

40)Check for proper fl ame appearance and glow on logs.

Installer Notice:

These instructions must be left with the appliance.

Regency® E21-3 Gas Fireplace Insert

23

Image 23
Contents E21 Gas Insert Congratulations Table of Contents Duplicate Serial No Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationGeneral Safety Information Important Message Save These InstructionsMinimum Fireplace Clearances Installation ChecklistCombustible board Clearances to CombustiblesHigh Elevation GAS ConnectionLug Detail Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Flue Connector InstallationVenting GAS Pipe Pressure TestingOffset Flue Adaptor Optional Brick Panel Valve DescriptionGAS Insert Aeration System Test for Flue Spillage27-23 LOG SET Installation27-23 27-30 27-27 27-24 27-28 27-25 27-2627-27 27-26 27-24 27-26 27-2527-27 27-25 27-23 27-27 27-29 27-24 27-26 27-29 27-2827-30 27-23 27-27 27-23 27-24 27-30 27-29 27-26 27-25 Ensure not to cover any burner portsDiagram Faceplate & Trim InstallationUse of substitute glass will Void all product warranties Flush Glass Flush LouversBAY Louvers Optional BAY FrontQty Description LPG Conversion Kit Contains Qty DescriptionDC Sparker Kit Contains Installation of the DC Sparker Heat Shield Full Screen Doors Screen Door Hinge Location Bottom Frame Wall Thermostat Remote Control Wall SwitchOperating Instructions Copy of Lighting Plate Instructions Maintenance Removing the FAN Door Glass ReplacementRemoving Valve Assembly Disconnect the powerMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay DoorFaceplate Assembly Conditions WarrantyInstaller Please complete the following information