Install Packaged Boiler CONTINUED

Change From Back Flue Outlet to Top Flue Outlet (Optional)

FIGURE 2

Install Non-Packaged Boiler

Fiberglass wool and ceramic fiber materials:

POSSIBLE CANCER HAZARD BY INHALATION

CAN CAUSE RESPIRATORY, SKIN AND EYE IRRITATION

This product contains fiberglass wool and ceramic fiber materials. Airborne fibers from these materials have been listed by the State of California as a possible cause of cancer through inhalation. Apply special care when handling ceramic fiber (chamber lining and base insulation) materials. Ceramic fibers can be converted to chrystobalites, a substance listed as a probable cause of cancer.

Suppliers of fiberglass wool products recommend the following precautions be taken when handling these materials:

Precautionary measures:

Avoid breathing fiberglass dust and contact with skin and eyes.

Use NIOSH approved dust/mist respirator.

Wear long-sleeved, loose fitting clothing, gloves and eye protection.

Wash work clothes separately from other clothing. Rinse washer thoroughly.

Operations such as sawing, blowing, tearout and spraying may generate airborne fiber concentration requiring additional protection.

First aid measures:

Eye contact — Flush eyes with water to remove dust. If symptoms persist, seek medical attention.

Skin contact — Wash affected areas gently with soap and warm water after handling.

7

Image 7
Contents This Manual Includes Installation Start-Up Boiler Parts Hazard Definitions Symbol DefinitionsWhen Calling or Writing About the Boiler Read This Page FirstTable of Contents Provide clearances around boiler see Figure Before Installing BoilerInstallations must comply with Before selecting boiler locationLay a foundation, if needed Provide air for combustion and ventilationPerform hydrostatic pressure test Install Packaged BoilerPlace boiler Tankless heater, if usedFiberglass wool and ceramic fiber materials Install Non-Packaged BoilerNon-Packaged SGO-3 through 6 position on site Install Non-Packaged Boiler Install burner also refer to instructions packed with burner Install Packaged and Non-Packaged BoilerInstall Packaged and Non-Packaged Boiler General chimney requirements Connect BreechingConnect Breeching Connect Steam Piping Install pipingGeneral piping information Connect Steam Piping Connect Steam Piping Condensate Receiver Capacity Table Optional reservoir pipingTo pipe tankless heater Connect Tankless Heater PipingBurner wiring Connect WiringGeneral wiring requirements Thermostat wiringConnect Wiring Low Water Cutoff Wiring Harness not furnished on a Boilers Connect Wiring Boiler Wiring for Probe-Type Lwco General oil piping requirements Connect Oil PipingOil piping connection at burner To place in operation Start-UpFill the system Tips for steam systemsCheck off steps as completed Check-Out ProcedureAppendix Burner adjustments for P and a boilersTo connect SGO boilers to indirect-fired water heaters Parts List Parts Drawing Dimensions DimensionsDimensions