Wayne WSS20, WSS10, WSS30 specifications Description, Specifications, Construction, Unpacking

Page 1

Operating Instructions and Parts Manual

WSS10, WSS20, WSS30

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Submersible Sump

System

Description

This submersible sump system is designed for indoor home sump applications. The system consists of a primary sump pump and a back-up sump pump.

The primary system operates on

120-volt household electric power. It is equipped with a 3-prong grounding type power cord. The motor is oil filled and sealed for cooler running and is

Specifications

designed to operate under water. The primary pump is provided with Switch Genius™ Technology to control the pump. When water is detected, the pump will start automatically.

The battery operated back-up sump pump is included in the event that the primary pump cannot function. It does not replace the primary pump. A float switch automatically turns on the backup sump pump when water activates the float. A battery (not included) must be installed to operate the back-up sump pump.

Model WSS10 consists of a WSCAP30 primary pump and an ESP15 backup pump. Model WSS20 consists of a

Power supply requirements

Motor

Liquid temperature range

Circuit requirements

Dimensions

Cut-in level (factory set)

Cut-out level (factory set)

WSS10

120V, 60 hz ▲

12V DC ●

Single phase, oil

filled ▲

40°F to 120°F

15 amps (min) ▲

11 inches high x

9 inches base

8inches

Approx. 3 inches

WSS20

120V, 60 hz ▲

12V DC ●

Single phase, oil

filled ▲

40°F to 120°F

15 amps (min) ▲

11-1/2 inches high x

9-3/4 inches base

8inches

Approx. 3 inches

WSS30

120V, 60 hz ▲

12V DC ●

Single phase, oil

filled ▲

40°F to 120°F

15 amps (min) ▲

11-1/2 inches high x

12 inches base

8inches

Approx. 3 inches

CDUCAP725 primary pump and an ESP15 backup pump. Model WSS30

Construction

consists of a CDUCAP850 primary pump and an ESP25 backup pump.

Unpacking

Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death.

Motor housing

Volute

Impeller

Shaft

Seals

Discharge

WSS10

Glass reinforced

thermoplastic ▲ ●

Thermoplastic ▲ ●

Glass reinforced

thermoplastic

Stainless steel

Buna N

1-1/2 inch NPT ▲

1-1/4 inch or

1-1/2 inch socket ●

WSS20

Cold rolled steel ▲

Glass reinforced thermoplastic ●

Cast iron ▲

Glass reinforced thermoplastic ●

Glass reinforced

thermoplastic

Low carbon steel

Buna N

1-1/2 inch NPT ▲

1-1/4 inch or

1-1/2 inch socket ●

WSS30

Cold rolled Steel ▲

Glass reinforced thermoplastic ●

Cast iron ▲

Glass reinforced thermoplastic ●

Glass reinforced

thermoplastic

Low carbon steel

Buna N

1-1/2 inch NPT ▲

1-1/2 inch socket ●

▲ Primary pump

Back-up pump

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

© 2009 Wayne Water Systems

For parts, product & service information

353501-001 2/09

 

visit www.waynepumps.com

 

Image 1
Contents Description SpecificationsConstruction UnpackingGeneral Safety Information Safety GuidelinesBack-up Pump Battery Requirements InstallationOperation Primary Pump WSS10, WSS20, WSS30Maintenance Primary Pump Maintenance Back-up PumpOperation Back-up Pump Symptom Possible Causes Corrective Action Troubleshooting Chart Primary PumpTroubleshooting Chart Back-up Pump Repair Parts List For replacement parts or technical assistance, callPrimary Pump, Models WSS20 and WSS30 Back-up Pump, Models WSS10 and WSS20 Back-up Pump, Model WSS30 Service Record Limited Warranty Déballage SpécificationsDirectives De Sécurité Back-up Pump BatteryGénéralités Sur La Sécurité Fonctionnement Pompe Principale Installation suiteFonctionnement Pompe de Secours Fonctionnement Pompe Principale suiteEntretien Pompe Principale Entretien Pompe de Secours Entretien Pompe Principale suiteGuide De Dépannage Pompe de Secours Guide De Dépannage Pompe PrincipalePompe Principale, Modèle WSS10 Liste de Pièces Détachées20 Fr 21 Fr 22 Fr Enregistrement d’entretien Garantie Limitée Especificaciones DescripciónConstrucción DesempacarInformaciones Generales de Seguridad Medidas de SeguridadRequisitos de la batería para la bomba de respaldo InstalaciónInstalación Continuación Funcionamiento Bomba PrimariaFuncionamiento Bomba de Respaldo Funcionamiento Bomba Primaria ContinuaciónMantenimiento Bomba de Respaldo Mantenimiento Bomba PrimariaGuía de diagnóstico de averías Bomba de Respaldo Guía de diagnóstico de averías Bomba PrimariaLista de Partes de Reparación Para piezas de repuestos o asistencia técnica, llame al32 Sp 33 Sp 34 Sp Registro de Servicios Garantía Limitada