Wayne WSS30 Safety Guidelines, General Safety Information, Back-up Pump Battery Requirements

Page 2

Operating Instructions and Parts Manual

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates an imminently hazardous

situation which, if not avoided, WILL result in death or serious injury.

Warning indicates a potentially hazardous

situation which, if not avoided, COULD result in death or serious injury.

Caution indicates a potentially hazardous

situation which, if not avoided, MAY result in minor or moderate injury.

Notice indicates important

information, that if not followed, may cause damage to equipment.

General Safety Information

CALIFORNIA PROPOSITION 65

This product or its power cord contains

chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

GENERAL SAFETY

Do not use to

pump flammable or explosive fluids such as gasoline, fuel oil, kerosene,

etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Personal injury and/or property damage

Battery

acid is

corrosive. Avoid spilling on skin or clothing. Eye protection must be worn when handling the battery.

A ground fault circuit interrupter is

required.

This pump must only be used to pump

clear water. This pump is not designed to handle effluent, salt water, brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials. Pump damage may occur if used in these applications and will void warranty.

Back-up Pump Battery

Requirements

1. Use only a new fully charged 12 volt deep cycle battery. Electrolyte level must be checked and maintained in accordance with manufacturer’s guidelines.

2.Battery sizes that will fit into the battery box are 24C, 24VCM, 27C, 27CM and 27F.

3.Battery recharge time will be different at each installation. Under normal conditions it will take two to four days to bring a deep cycle battery back to full charge after it has been discharged. If electrical power to the house is lost more than once a week, consider keeping a spare, fully-charged battery to replace an exhausted battery for the standby sump pump.

Installation

1. Install in a sump pit per the minimum diameter required (WSS10: 11 inch, WSS20: 12 inch, WSS30: 15 inch in diameter). Construct sump pit of tile, concrete, steel or plastic. Position primary pump switch AWAY from any inlets so that incoming water does not contact the switch face. See Figure 1(a) - 1(c).

2.The unit should be located and rest on a solid, level foundation. Do not place pump directly on clay, earth, gravel or sandy surface. These surfaces contain small stones, gravel, sand, etc. that may clog or damage the pump and cause pump failure.

Flood risk. If flexible discharge hose is

used, make sure pump is secured in sump pit to prevent movement. Failure to secure pump could allow pump movement and switch interference and prevent pump from starting or stopping.

3.Using PVC cement and primer, connect 1-1/4 inch or 1-1/2 inch (only 1-1/2 inch for WSS30) rigid pipe to the system's discharge fitting.

Support pump and piping when

assembling and after installation. Failure to do so could cause piping to break, pump to fail, etc. which could result in property damage and/or personal injury.

4.Place battery in box. Attach red cable from battery box control panel to positive battery terminal. Attach black cable to the negative terminal. Place cover on battery box.

could result.

All wiring must be performed by a

qualified electrician. Failure to follow this warning could result in fatal electrical shock.

If the basement has water or moisture on the floor, do not walk on wet area until all

power is turned off. If the shutoff box is in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.

Do not

expose battery to sparks or flames as an explosion or fire could

result.

www.waynepumps.com

WSS10

 

Grounded

Grounded

 

 

Outlet

Outlet

 

 

 

 

Discharge pipe

Inlet

 

24

pipe

 

 

inch min

Check valve

 

 

.

 

11 inch

Cap Switch

 

Diameter

ON @ 8 inches

Figure 1 (a)

min.

OFF @ approx. 3 inches

2

 

 

Image 2
Contents Construction SpecificationsDescription UnpackingBack-up Pump Battery Requirements Safety GuidelinesGeneral Safety Information InstallationWSS10, WSS20, WSS30 Operation Primary PumpOperation Back-up Pump Maintenance Back-up PumpMaintenance Primary Pump Troubleshooting Chart Primary Pump Symptom Possible Causes Corrective ActionTroubleshooting Chart Back-up Pump For replacement parts or technical assistance, call Repair Parts ListPrimary Pump, Models WSS20 and WSS30 Back-up Pump, Models WSS10 and WSS20 Back-up Pump, Model WSS30 Service Record Limited Warranty Spécifications DéballageGénéralités Sur La Sécurité Back-up Pump BatteryDirectives De Sécurité Installation suite Fonctionnement Pompe PrincipaleEntretien Pompe Principale Fonctionnement Pompe Principale suiteFonctionnement Pompe de Secours Entretien Pompe Principale suite Entretien Pompe de SecoursGuide De Dépannage Pompe Principale Guide De Dépannage Pompe de SecoursListe de Pièces Détachées Pompe Principale, Modèle WSS1020 Fr 21 Fr 22 Fr Enregistrement d’entretien Garantie Limitée Construcción DescripciónEspecificaciones DesempacarRequisitos de la batería para la bomba de respaldo Medidas de SeguridadInformaciones Generales de Seguridad InstalaciónFuncionamiento Bomba Primaria Instalación ContinuaciónFuncionamiento Bomba Primaria Continuación Funcionamiento Bomba de RespaldoMantenimiento Bomba Primaria Mantenimiento Bomba de RespaldoGuía de diagnóstico de averías Bomba Primaria Guía de diagnóstico de averías Bomba de RespaldoPara piezas de repuestos o asistencia técnica, llame al Lista de Partes de Reparación32 Sp 33 Sp 34 Sp Registro de Servicios Garantía Limitada