WSS10, WSS20, WSS30
WSS20 |
| Grounded | |
|
| ||
Grounded | Outlet | ||
Outlet |
|
| |
|
| Discharge pipe | |
Inlet pipe |
| 24 | |
| inch min. | ||
| Check valve | ||
|
| ||
| (not shown) |
| |
| 12 inch | Cap Switch | |
| Diameter | ON @ 8 inches | |
Figure 1 (b) | min. | OFF @ approx. 3 inches | |
WSS30 |
| Grounded | |
Grounded | |||
Outlet | |||
Outlet |
|
|
Discharge pipe
Inlet pipe |
| 24 | ||
| inch min. | |||
| Check valve |
| ||
| 15 inch |
| Cap Switch | |
Figure 1 (c) | Diameter |
| ON @ 8 inches | |
min. |
| OFF @ approx. 3 inches | ||
Installation (continued) | 7. | Protect electrical cord from sharp | ||
| objects, hot surfaces, oil and | |||
| If cables are |
| ||
|
| chemicals. Avoid kinking the | ||
| reversed, damage to |
| cord and replace damaged cords | |
the control box or battery could result |
| immediately. | ||
and will void the warranty. | 8. | A sump pit cover must be installed | ||
5. Place battery box within six feet of | ||||
| to prevent debris from clogging or | |||
the sump and a 115 VAC separately |
| |||
| damaging the pump. | |||
fused outlet. The outlet must |
| |||
|
| |||
be protected by a ground fault | Operation - Primary Pump | |||
circuit interrupter (GFCI). The area |
|
| ||
must also be clean, dry and well- |
| Always | ||
ventilated. |
|
| ||
| disconnect the power source | |||
6. Plug the float switch, pump and | ||||
before attempting to install, | ||||
charger into the control box. The | service, relocate or maintain | |||
connections are marked on the | the pump. Never touch sump | |||
control box. |
| pump, pump motor, water or discharge | ||
|
| piping when pump is connected to |
electrical power. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
1.A ground fault circuit interrupter (GFCI) is required (see Figure 2).
Figure 2
Risk of electrical shock! This pump
is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock.
Never cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable.
2.The primary pump is only for use on 120 volt (single phase), 60 hz, 15 amp service and is equipped with a
3.Insert the pump power cord plug directly into the back of the water sensor cord plug.
4.Fill sump with water. The pump will start automatically when the water is about
•Sump pump will run a minimum of 4 seconds, to a maximum of 16 before stopping.
•Sump pump run time will be determined by the sump pit size and water flow rate into the sump pit.
•Under flooding conditions, the sump pump will stop for 1 second, every 16 seconds, and automatically turn back on.
5.Do not operate the pump unless it is submerged in water. Dry running causes pump failure.
www.waynepumps.com