Wayne SYLT30 warranty Installation

Page 2

Operating Instructions and Parts Manual

Assembly (continued)

3.Place pump assembly inside tank, keeping float away from the walls of the tank.

4.Run power cord and switch cord through holes in the power cord seal.

5.Insert seals into the holes in the lid as shown in Figure 2.

Figure 2: Attach Seals to Tank Lid

6.Lubricate discharge pipe and seal with soapy water.

7.Slide the lid (while holding the discharge seal in place) over the discharge pipe.

8.Line up the holes in the lid with the threads in the tank.

9.Secure lid to tank using the screws and washers provided. (See Figure 3) Hand tighten all screws and then fully tighten with a 7/16 in. wrench. Do not over-tighten.

Installation

Tools Required for Installation (not included): PVC Glue, 7/16 in. wrench and a screwdriver.

P

C

 

V

1. Connect discharge pipe (See Figure 4) on Laundry Tray System to an existing drain. Make sure all connections are sealed.

2.Insert 1-1/2 in. Schedule 40 PVC pipe into vent opening on top of Laundry Tray System (See Figure 4). Insert pipe 2 to 3 inches into vent opening.

3.Connect Intake of this Laundry Tray System (See Figure 4) to your washing machine or other source. The threads are 1-1/2 in. NPT.

Ventilation

GFCI

Outlet

Water

Inlet

Support pump and piping when

assembling and after installation. Failure to do so could cause piping to break, pump to fail, etc. which could result in property damage and/or personal injury.

4.Protect electrical cord from sharp objects, hot surfaces, oils, and chemicals. Avoid kinking the cord and replace damaged cords immediately.

NOTE: Make sure there is adequate room for the float switch to move freely for operation.

This pump is NOT designed for use in

septic tanks or underground vaults to handle raw sewage or effluents. NEVER use this unit in hazardous or explosive locations.

Discharge

Check Valve

Figure 3: Attach Seals to Tank Lid

Keep float free of obstruction

Place the system on a flat surface

Figure 4: Installation

www.waynepumps.com

2

Image 2
Contents Assembly Safety GuidelinesGeneral Safety Information DescriptionInstallation Outlet MaintenanceOperation Grounding BladeTroubleshooting Chart Problem Possible Causes Corrective ActionsFor Replacement Parts or Technical Assistance, Call Limited Warranty Généralités sur la Sécurité DéballageDirectives de Sécurité AssemblageFilets sont de 3,8 cm 1 1/2 po NPT Assemblage suiteInstructions dUtilisation et Pièces de Recahnge Risque de blessure FonctionnementBroche de mise à la terre Dépannage Problème Causes Possibles Mesures correctivesPour Pièces de Rechange ou Assistance Technique, Appeler Garantie Limitée Medidas de Seguridad DescripciónDesempaque EnsamblajeInstalación Funcionamiento MaintenimientoDiagnóstico y resolución de problemas Problema Causas posibles Acciones a tomarPara Ordenar Repuestos o Asistencia Técnica, llame Notas Notas Garantía Limitada

SYLT30 specifications

The Wayne SYLT30 is an innovative and advanced fuel dispenser designed for high-performance service stations, combining state-of-the-art technology with user-friendly interfaces. This model is particularly known for its robust construction, making it ideal for both high-volume and heavy-duty applications. Featuring a sleek and modern design, the SYLT30 seamlessly integrates into any fueling environment while ensuring operational efficiency and reliability.

One of the main features of the Wayne SYLT30 is its high-capacity fuel dispensing capability. With its ability to handle multiple fueling products, this dispenser can cater to a diverse customer base. It usually comes with multiple hose configurations, enabling simultaneous dispensing of different fuel types, including gasoline, diesel, and alternative fuels. This versatility allows service stations to meet diverse market demands effectively.

The technology behind the SYLT30 enhances not only performance but also user experience. It employs advanced electronic systems for precise fuel measurement and automatic shut-off features, helping to prevent overflows and ensuring safety during refueling operations. Additionally, the dispenser integrates innovative payment technologies, including contactless payment options and robust security features, ensuring quick and secure transactions for customers.

The SYLT30 is also equipped with an intuitive user interface that simplifies the fueling process. The clear display and easy-to-navigate menus guide users through the fueling process, providing information such as fuel type, price per gallon, and transaction totals. This technology significantly reduces wait times, improving overall customer satisfaction at the fueling station.

Moreover, the Wayne SYLT30 is built with durability in mind, using high-quality materials that withstand harsh environmental conditions. Its corrosion-resistant components ensure longevity, while regular maintenance is streamlined through easy access to internal parts. This reduces downtime and maintenance costs, making the SYLT30 a cost-effective choice for business owners.

In summary, the Wayne SYLT30 is a feature-rich fuel dispenser that combines cutting-edge technology, versatility, and durability. Its high-capacity dispensing, advanced safety features, user-friendly interface, and robust construction make it an optimal choice for service stations looking to enhance their fueling operations and improve customer service. As the fuel industry continues to evolve, models like the SYLT30 are paving the way for modern and efficient fueling solutions.