Wayne SYLT30 warranty Operation, Maintenance, Outlet, Grounding Blade, Always disconnect

Page 3

SYLT30

Operation

Always disconnect

the power source before attempting to install, service, relocate or maintain the pump. NEVER touch the sump pump, pump motor, water or discharge piping when pump is connected to electrical power. NEVER handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.

1.It is required that this unit be plugged into a Ground Fault Circuit Interrupter (GFCI) as shown in Figure 5. Consult a local electrician for installation and availability.

Power Cord

GFCI

Outlet

 

 

 

TEST

 

RESET

Grounding Blade

Figure 5: Grounding outlet and power cord

Risk of electrical

shock! This pump is supplied with a grounding conductor and grounding type attachment

plug. Use a grounded receptacle to reduce the risk of fatal electrical shock. NEVER cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable.

2.Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Replace or repair damaged or worn cords immediately. Use wire of adequate size to minimize voltage drop at the motor.

3.Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.

4.This pump is only for use on 120 Volt (single-phase), 60 Hz, 15 amp service and is equipped with a 3-conductor cord and 3-prong, grounding type plug. Insert the float switch cord plug directly into a GFCI protected 120 volt outlet. Do NOT use an extension cord.

5.Insert the pump power cord plug directly into the back of the float switch cord plug (See Figure 6).

6.Test operation of the system by adding water to the inlet. The pump will start automatically when the water has filled the reservoir to a depth of approximately 9 inches. The pump will stop when the water depth is approximately 4 inches. The pump will cycle thereafter as required.

Do NOT operate the pump unless it is

submerged in water. Dry running causes pump failure. The motor is equipped with an automatic reset thermal protector.

Maintenance

Always disconnect

the power source before attempting to install, service, relocate or maintain the pump.

NEVER touch sump pump, pump motor, water or discharge piping when pump is connected to electrical power. NEVER handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.

Risk of personal

injury! Wear safety glasses at all times when performing maintenance on this pump

system. Failure to follow this warning could result in death or serious injury.

1.Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under pressure and the motor is hot.

This pump

 

contains

O I L

dielectric motor oil for

lubrication and motor heat transfer. This oil can be

harmful to the environment. Check state environmental laws before disposing of this oil.

2.Disassembly of the motor prior to expiration of warranty will void the warranty. If repairs are required, see troubleshooting chart.

3.Inlet should be kept clean and free of all foreign objects and inspected annually. A clogged inlet will damage the pump.

4.Pump should be checked monthly for proper operation.

GFCI Outlet

Pump Power

Cord

Float Switch

Piggyback Plug

Figure 6: Piggyback Plug and Power Cord

www.waynepumps.com

3

Image 3
Contents Description Safety GuidelinesGeneral Safety Information AssemblyInstallation Grounding Blade MaintenanceOperation OutletProblem Possible Causes Corrective Actions Troubleshooting ChartFor Replacement Parts or Technical Assistance, Call Limited Warranty Assemblage DéballageDirectives de Sécurité Généralités sur la SécuritéAssemblage suite Instructions dUtilisation et Pièces de RecahngeFilets sont de 3,8 cm 1 1/2 po NPT Fonctionnement Broche de mise à la terreRisque de blessure Problème Causes Possibles Mesures correctives DépannagePour Pièces de Rechange ou Assistance Technique, Appeler Garantie Limitée Ensamblaje DescripciónDesempaque Medidas de SeguridadInstalación Maintenimiento FuncionamientoProblema Causas posibles Acciones a tomar Diagnóstico y resolución de problemasPara Ordenar Repuestos o Asistencia Técnica, llame Notas Notas Garantía Limitada

SYLT30 specifications

The Wayne SYLT30 is an innovative and advanced fuel dispenser designed for high-performance service stations, combining state-of-the-art technology with user-friendly interfaces. This model is particularly known for its robust construction, making it ideal for both high-volume and heavy-duty applications. Featuring a sleek and modern design, the SYLT30 seamlessly integrates into any fueling environment while ensuring operational efficiency and reliability.

One of the main features of the Wayne SYLT30 is its high-capacity fuel dispensing capability. With its ability to handle multiple fueling products, this dispenser can cater to a diverse customer base. It usually comes with multiple hose configurations, enabling simultaneous dispensing of different fuel types, including gasoline, diesel, and alternative fuels. This versatility allows service stations to meet diverse market demands effectively.

The technology behind the SYLT30 enhances not only performance but also user experience. It employs advanced electronic systems for precise fuel measurement and automatic shut-off features, helping to prevent overflows and ensuring safety during refueling operations. Additionally, the dispenser integrates innovative payment technologies, including contactless payment options and robust security features, ensuring quick and secure transactions for customers.

The SYLT30 is also equipped with an intuitive user interface that simplifies the fueling process. The clear display and easy-to-navigate menus guide users through the fueling process, providing information such as fuel type, price per gallon, and transaction totals. This technology significantly reduces wait times, improving overall customer satisfaction at the fueling station.

Moreover, the Wayne SYLT30 is built with durability in mind, using high-quality materials that withstand harsh environmental conditions. Its corrosion-resistant components ensure longevity, while regular maintenance is streamlined through easy access to internal parts. This reduces downtime and maintenance costs, making the SYLT30 a cost-effective choice for business owners.

In summary, the Wayne SYLT30 is a feature-rich fuel dispenser that combines cutting-edge technology, versatility, and durability. Its high-capacity dispensing, advanced safety features, user-friendly interface, and robust construction make it an optimal choice for service stations looking to enhance their fueling operations and improve customer service. As the fuel industry continues to evolve, models like the SYLT30 are paving the way for modern and efficient fueling solutions.