EVAPORATOR PRESSURE DROPS

80

 

 

 

 

A

B

 

70

 

 

 

60

 

C

 

 

 

D

 

 

 

50

 

 

 

40

 

 

 

30

 

 

 

20

 

 

 

10

 

 

 

5000

10000

15000

20000

A:QLAC 040-045

B:QLAC 050

C:QLAC 060-070

D:QLAC 080

80

 

 

 

70

 

E

 

 

 

 

60

 

 

G

 

 

 

 

 

F

 

50

 

 

 

 

 

 

H

40

 

 

 

30

 

 

 

20

 

 

 

10

 

 

 

15000

20000

25000

30000

E:QLAC 090

F:QLAC 110

G:QLAC 120

H:QLAC 130

80

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

I

L

M

N

O

60

 

 

 

 

 

 

 

 

 

 

 

 

P

50

 

 

 

 

 

 

40

 

 

 

 

 

 

30

 

 

 

 

 

 

20

 

 

 

 

 

 

10

 

 

 

 

 

 

25000

30000

35000

 

40000

45000

50000

I:QLAC 140

L:QLAC 160

M:QLAC 190

N:QLAC 210

O:QLAC 240

P:QLAC 260

60

 

 

 

 

 

 

 

Q

R

 

 

50

 

 

 

S

T

 

 

 

 

 

 

 

 

 

U

40

 

 

 

 

 

30

 

 

 

 

 

20

 

 

 

 

 

10

 

 

 

 

 

40000

50000

60000

70000

80000

90000

Q:QLAC 300

R:QLAC 320

S:QLAC 380

T:QLAC 430

U:QLAC 500

19

06617645-02

Image 19
Contents Qlac Index EC Declaration of Conformity Technical Features Microprocessors EvaporatorsHydraulic circuit K versions only Electrics enclosureFree cooling version FC Heat Recovery VersionOther Versions Heat pump version HPWater Chillers and Heat Pumps Technical DataQlac / LS Low noise version 120 130 140 160 190 210 240 260 300 320 380 430 500 Qlac / XL Extra Low noise version ###206,1 060 040045 050110 070080 090160 120130 140260 190210 240Qlac / HP / LS LOW Noise Version Heating Capacities and Compressor Input Power TA C PC kW PA kW Evaporator Pressure Drops Water Pumps Available Static Pressure Free Cooling Capacity Mod 040 045 050 060 070 080 090 110 Partial Heat Recovery CapacityCccp Ipcf Compressors Capacity Step Controls Correction TableWfcf Pdcf Correction TablesSound Levels LOW Noise Version Electrical DataSound Levels Extra LOW Noise Version Inspection Lifting and site handling Installation Instructions GeneralLocation and Minimum Clearances Hydraulic Connections Operational Limits Ambient air temperatureEvaporator water flow rate Start up Electrical ConnectionsStart UP Before start-upControl Device SET Point Differential Reset Type Control and Safety Device SettingsCapacity Steps Control Device Every six months Maintenance and Periodic ChecksRefrigerant Circuit Repair Environmental Protection Dimensions 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02