Environmental Protection

European legislation regarding the use of ozone depleting substances forbids the release of refrigerants to the atmosphere. They must be reclaimed and returned to the vendor, or to authorised re-cyclers at the end of their operating life.

R407C refrigerant is deemed to be a controlled substance and is therefore subject to this legislation.

Particular care is required during servicing operations in order to prevent refrigerant loss.

De-commissioning

When the unit reaches the end of its service life and requires removal or replacement, the following operations are recommended:-

-the unit refrigerant must be reclaimed by trained personnel and returned to an authorised re-cycling centre

-compressor lubricating oil should be recovered and sent to an authorised re-cycling centre

-the unit frame, coil, heat exchanger etc, should be dismantled and subdivided into material type; bear in mind that copper and aluminium are present in substantial quantities in the unit.

These operations aid material recovery and recycling processes, reducing environmental impact.

31

06617645-02

Image 31
Contents Qlac Index EC Declaration of Conformity Technical Features Microprocessors EvaporatorsHydraulic circuit K versions only Electrics enclosureFree cooling version FC Heat Recovery VersionOther Versions Heat pump version HPWater Chillers and Heat Pumps Technical DataQlac / LS Low noise version 120 130 140 160 190 210 240 260 300 320 380 430 500 Qlac / XL Extra Low noise version ###206,1 060 040045 050110 070080 090160 120130 140260 190210 240Qlac / HP / LS LOW Noise Version Heating Capacities and Compressor Input Power TA C PC kW PA kW Evaporator Pressure Drops Water Pumps Available Static Pressure Free Cooling Capacity Mod 040 045 050 060 070 080 090 110 Partial Heat Recovery CapacityCccp Ipcf Compressors Capacity Step Controls Correction TableWfcf Pdcf Correction TablesSound Levels LOW Noise Version Electrical DataSound Levels Extra LOW Noise Version Inspection Lifting and site handling Installation Instructions GeneralLocation and Minimum Clearances Hydraulic Connections Operational Limits Ambient air temperatureEvaporator water flow rate Start up Electrical ConnectionsStart UP Before start-upControl Device SET Point Differential Reset Type Control and Safety Device SettingsCapacity Steps Control Device Every six months Maintenance and Periodic ChecksRefrigerant Circuit Repair Environmental Protection Dimensions 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02 06617645-02