Nimbus Water Systems MN-800-TF manual §9.2 TDS Monitor Instructions, Specifications

Page 22

§9.2 TDS MONITOR INSTRUCTIONS

Model TDS-2B TDS Monitor

Part # 100860

The Nimbus TDS-2B TDS Monitor is designed to operate within the Remote Bypass Unit of the Nimbus MN system. It is installed inside the upper left corner of the Bypass Unit frame and is connected to a tee fitting installed in the product water output line. The Monitor is powered by a 9V battery accessible via a sliding cover at the rear of the case. When the red front panel push- button switch is pressed, the probe mounted in the product water line senses the TDS level in the water flow. The monitor will then act to illuminate the green LED indicator if the product water TDS is below the preset level or the red LED if the product water TDS exceeds the preset level. The monitor is turned off when the push-button is released.

Specifications

 

Preset Level Selection*

50/75/100/150/200/250/300/500 ppm

(default 100 ppm)

 

Power Supply

9V DC

Sensing Method

AC signal conductivity

Actuation

Push-button switch

*Not temp compensated – levels calibrated to 25°C/77°F

Preset Level Adjustment

The TDS Monitor is preset to 100 ppm. To change the preset level, remove the small screw at the center of the rear cover. Carefully remove the rear cover assembly. On the circuit board inside the rear cover locate the 8-position selector switch. The switches marked 1 through 8 determine the preset level. With a ballpoint pen or small screwdriver place the number 3 switch in the “OFF” position, then place the new TDS level switch in the “ON” position (top end depressed). The corresponding TDS preset for each switch is as follows 1=50, 2=75, 3=100, 4=150, 5=200, 6=250, 7=300, 8=500. Only one of the eight switches should be in the “ON” position. When finished, re-install the assembly in reverse order.

22

Image 22
Contents MN-800-TF Nimbus MN-800 TF Reverse Osmosis Treatment System §1.0 MN-800 TF System Specifications Model noPage Page Ancillary Equipment §3.2 Operating Limitations §3.0 PRE-INSTALLATION Procedures§3.1 Packaging §3.3 Operating Parameters§4.2.1 Tank Preparation and Installation §4.0 Installation§4.2 System Plumbing Installation Guide Lines §4.1 LocationPage §4.2.3 RO Drain Connections §4.2.2 BY-PASS Panel Preparation and Installation§4.2.3 RO Feed Water Connection §4.3 ElectricalPage §5.0 System Flush and Performance Verification Immediately§5.2.1 Flow Tests §5.2.4 LOW Pressure Switch Test§5.2.5 Tank Pressure Switch Test §5.2.2 Concentrate to Product Ratio§7.0 Service §7.1 LOW Pressure Switch Adjustment §6.0 Operation and Maintenance§6.3 Quarterly Service §6.1 Daily System Checks§7.2 Tank Pressure Switch Adjustment §7.3 Membrane Replacement see FigurePage Page §7.4 PRE Filter Carbon Cartridge Replacement §7.5 POST-FILTER Carbon Cartridge ReplacementPage §8.0 Parts and Accessories Housings§9.0 Attachments §9.1 Remote Bypass System Instructions Specifications §9.2 TDS Monitor Instructions§9.3 Warranty

MN-800-TF specifications

The Nimbus Water Systems MN-800-TF is an innovative water filtration system designed to provide homes with clean, safe, and great-tasting water. Emerging as a leading solution in the water purification market, the MN-800-TF stands out due to its advanced features and cutting-edge technologies that cater to diverse filtration needs.

One of the main features of the MN-800-TF is its multi-stage filtration process, which includes a combination of sediment filters, activated carbon, and reverse osmosis membranes. This multi-tier approach ensures that a wide range of impurities such as chlorine, heavy metals, sediments, and even microorganisms are effectively removed from the water. This results in not only improved taste but also enhanced safety for household consumption.

The system utilizes advanced filtration technologies, including a high-capacity reverse osmosis membrane that boasts an impressive rejection rate for dissolved solids. This technology ensures that the water retains essential minerals while eliminating harmful contaminants. The activated carbon filters are designed to reduce chlorine levels and volatile organic compounds, resulting in water that is pure and refreshing.

In terms of user convenience, the MN-800-TF is equipped with an easy-to-read digital display that provides real-time information regarding filter status and water quality. The system also features a simple, intuitive setup process and space-saving design, making it suitable for both small and large homes. The compact design allows for installation under sinks or in utility rooms, optimizing space without compromising efficiency.

Another notable characteristic of the MN-800-TF is its sustainable approach. The system is designed to produce minimal wastewater during the filtration process, which is a critical consideration given the rising concern over water conservation. Moreover, by using a reusable filter system, users can reduce plastic waste generated from traditional bottled water usage.

The Nimbus Water Systems MN-800-TF is also backed by robust customer support and a warranty, ensuring peace of mind for users. Overall, this water filtration system integrates advanced technology and user-friendly features, making it an optimal choice for anyone looking to enhance their home’s water quality. With its combination of efficiency, sustainability, and reliability, the MN-800-TF truly embodies the future of home water purification.