Generac Power Systems H-100 Authorized Service Dealer Location, Inside Front Cover

Page 3

Table of Contents

Table of Contents

 

Safety Rules

Inside Front Cover

General Information

2

Introduction

2

Features

2

Panel Setup

2

Changing the Controller Configuration

2

Customization

2

The Measurement “Engine”

3

Analog Channels

3

Analog Maths

3

Analog Alarms

4

Other Analog Options

5

Analog Sensor Ratings

5

Output Functions

5

Spare Analog Channels

5

Engine Management

6

Generator Parameters

6

Engine Settings

6

Starting and Stopping - Sequence Diagrams

7

Voltage Regulator (Option)

8

Governor (Speed Regulator) Option

8

Trending

9

Remote Trending

9

Local Trending

10

GenLink Local Trending Setup

10

Trigger/Collection Type

13

The ILC

10

The Front Panel Display

11

Left Display

11

Right Display

11

Left Display Pages

11

Right Display Pages

13

Alarms

13

Engine

14

Status

16

Service

17

Generator

18

Diagnostics

19

Exercise/HTS

21

The Control Panel

23

The Alarm Log

23

H-100 Control Panel Technical Manual

The Event Log

23

Maintenance Settings

24

Air/Fuel Ratio Control (Option)

24

I2T Current Monitoring (Option)

24

Internal Exercise Function

25

QuietTest® Setup Using GenLink

25

Normal Exercise Setup Using GenLink

26

QuietTest® Setup Using Front Panel

27

Set Date and Time

33

Date and Time Setup Using GenLink

33

Date and Time Setup Using Front Panel

33

Adjust Display Contrast

34

Enable Generac Commercial Transfer Switch (HTS) ....

35

HTS Setup Using GenLink

35

HTS Setup Using Front Panel

35

Communications

37

Remote Annunciator Connection (Option)

37

New Generation GenLink (NGG)

37

GenLink Relay Control

37

Set Engine Hours

37

Absolute Maximum Ratings

37

Environmental Ratings

37

Appendix

38

Appendix A — Analog Functions

38

Appendix B — H-100 General I/O and Connector

 

Information

40

H-100 Analog Inputs

40

H-100 Digital Outputs

41

H-100 Digital Inputs

41

H-100 Digital Output Functions

42

H-100 Connector Pin Descriptions

46

Appendix C — Miscellaneous H-100

 

Internal Alsrms/Warnings

47

Notes

48

AUTHORIZED SERVICE

DEALER LOCATION

To locate the nearest AUTHORIZED SERVICE

DEALER, please call this number:

1-800-333-1322

DEALER LOCATION INFORMATION CAN BE OBTAINED AT THIS NUMBER, or visit the website at www.generac.com.

1

Image 3
Contents Control Panel Technical Manual  General Hazards  Inside Front Cover Authorized Service Dealer Location‹ Customization FeaturesPanel Setup IntroductionThen Measurement Engine‹ Analog Channels ‹ Analog Maths‹ Analog Alarms ‹ Analog Sensor Ratings Output Functions‹ Other Analog Options ‹ Spare Analog ChannelsParameter Units ‹ Engine SettingsEngine Management ‹ Generator ParametersCLOSED? Starting and Stopping Sequence DiagramsVoltage Regulator Option Chart Voltage Regulator OptionGovernor Speed Regulator Option Governor Speed Regulator Option Chart Trending‹ Remote Trending ‹ Genlink Local Trending Setup ILC‹ Local Trending ‹ Right Display Front Panel Display‹ Left Display Pages ‹ Left DisplaySwitch VoltsAlrm Log Other Power‹ Alarms Graph HzEngine General Information Status Service Generator Diagnostics General Information EXERCISE/HTS TDN Event LOG Alarm LOGHome Control PanelMaintenance Settings AIR/FUEL Ratio Control OptionI2T Current Monitoring Option Internal Exercise Function Quiettest Setup Using GenlinkNormal Exercise Setup Using Genlink Quiettest Setup Using Front Panel General Information General Information Normal Exercise Setup Using Front Panel General Information General Information ‹ Date and Time Setup Using Genlink ‹ Date and Time Setup Using Front PanelSET Date and Time Adjust Display Contrast ‹ HTS Setup Using Front Panel ‹ HTS Setup Using GenlinkGeneral Information Remote Annunciator Connection Option NEW Generation Genlink NGG CommunicationsLinear POLY1ST Appendix a Analog FunctionsThermistor Pressure POLY3RDCurrent Calscale POLY1STN2‹ H-100 Analog Inputs Appendix B H-100 General I/O and Connector Information‹ H-100 Digital Inputs ‹ H-100 Digital Outputs‹ H-100 Digital Output Functions GOV POS HI Alarm Analog 6 FaultFuel PRS Fault Inlt TMP FaultENG RPM HI Alarm TOT PWR HI AlarmTOT PWR LO Alarm GEN Freq FaultChck C PHS ROT Fault RLY ActiveUSR Config Chck V PHS ROTWire Signal Description ‹ H-100 Connector PIN DescriptionsAppendix C Miscellaneous H-100 Internal ALARMS/WARNINGS Control Panel Technical Manual Control Panel Technical Manual Generac Power SYSTEMS, INC

H-100 specifications

Generac Power Systems H-100 is an innovative and robust product that has garnered attention for its reliability and performance in power generation. This generator is primarily designed for both residential and commercial applications, providing a seamless backup power solution during outages.

One of the standout features of the H-100 is its powerful engine. Equipped with a state-of-the-art gas engine, this generator can deliver up to 100 kW of power, ensuring that homes, businesses, and critical facilities remain operational even in the most challenging conditions. The engine is engineered for efficiency and longevity, reducing maintenance needs and minimizing fuel consumption.

Another significant aspect of the H-100 is its advanced Smart Management System. This technology ensures optimal power usage by intelligently distributing the electrical load among connected devices. By prioritizing essential circuits, the generator maximizes efficiency and prolongs operational time during power outages.

The H-100 also boasts a remarkable noise reduction feature. Its innovative design includes sound attenuation measures, allowing the generator to operate quietly, which is particularly beneficial in residential areas where noise pollution can be a concern. This focus on quieter operation enhances user comfort and complies with noise regulations.

Durability is a key characteristic of the Generac H-100. Constructed with high-quality materials, it is designed to withstand harsh weather conditions and heavy usage. This generator is built for longevity, providing users with reliable performance and peace of mind.

The H-100 is also equipped with a user-friendly control panel. This intuitive interface allows users to monitor the generator's performance, manage settings, and perform necessary maintenance checks easily. The integration of remote monitoring capabilities enables users to assess the generator's status from anywhere, adding an extra layer of convenience.

Lastly, Generac Power Systems offers comprehensive support and resources for H-100 users. Their commitment to customer service includes accessible informational materials, a reliable warranty program, and a national network of service professionals. This ensures that users receive the assistance they need to maintain their generators optimally.

In summary, the Generac Power Systems H-100 stands out as a reliable, efficient, and user-friendly power generation solution. With its robust engine, smart management system, noise reduction features, and durable construction, it is well-suited to meet the demands of both residential and commercial applications.