STATUS

There are two System Status pages. These pages show the system status, system time, and system versions.

Do the following to view the system status pages:

Press the “MENU” button.

Press the button twice.

Press the “ENTER” button.

This is a typical first System Status page.

LINE 1: Engine Running Status. It can have the fol- lowing values:

“Stopped, Key SW Off”

The engine is stopped and the key switch is in the OFF position.

“Running from Manual”

The engine is starting or running and the key switch is in the MANUAL position.

“Running from 2-wire”

The engine is starting or running because the 2-wire start signal was activated and the key switch is in the AUTO position.

“Running from serial”

The engine is starting or running because the GenLink commanded it to start and the key switch is in the AUTO position.

“Running exercise”

The engine is starting or running because internal exercise was activated and the key switch is in the AUTO position.

“Stopped, Key SW Auto”

The engine is stopped and the key switch is in the AUTO position.

“Running, QuietTest”

The engine is starting or running because QuietTest® was activated and the key switch is in the AUTO posi- tion.

“Running, HTS Xfer SW”

The engine is starting or running because the HTS(s) indicated a need for the generator power and the key switch is in the AUTO position.

LINE 2: Generator Status. It can have the following values:

“Resetting”

The generator control system is resetting.

“Stopped”

Generator is stopped and not preheating.

“Stopped, Preheating “

Generator is stopped and preheating.

“Cranking”

Generator is starting and not preheating.

“Cranking, Preheating”

Generator is starting and preheating.

“Pause between starts”

Generator is pausing between consecutive start attempts.

“Started,not to speed”

Generator is started, but has not attained normal running speed yet.

“Warming, Alarms Off “

Generator is started and is up to speed, but is waiting for warmup timer to expire.

“Warmed Up,Alarms Off”

Generator is started and warmed up, but the hold-off alarms are not yet enabled.

“Warming, Alarms On”

Generator is started and the hold-off alarms are enabled, but is waiting for warmup timer to expire.

16

Image 18
Contents Control Panel Technical Manual  General Hazards  Authorized Service Dealer Location Inside Front CoverIntroduction FeaturesPanel Setup ‹ Customization‹ Analog Maths Measurement Engine‹ Analog Channels Then‹ Analog Alarms ‹ Spare Analog Channels Output Functions‹ Other Analog Options ‹ Analog Sensor Ratings‹ Generator Parameters ‹ Engine SettingsEngine Management Parameter UnitsStarting and Stopping Sequence Diagrams CLOSED?Voltage Regulator Option Chart Voltage Regulator OptionGovernor Speed Regulator Option Governor Speed Regulator Option Chart Trending‹ Remote Trending ‹ Genlink Local Trending Setup ILC‹ Local Trending ‹ Left Display Front Panel Display‹ Left Display Pages ‹ Right DisplaySwitch VoltsAlrm Log Graph Hz Power‹ Alarms OtherEngine General Information Status Service Generator Diagnostics General Information EXERCISE/HTS TDN Control Panel Alarm LOGHome Event LOGMaintenance Settings AIR/FUEL Ratio Control OptionI2T Current Monitoring Option Quiettest Setup Using Genlink Internal Exercise FunctionNormal Exercise Setup Using Genlink Quiettest Setup Using Front Panel General Information General Information Normal Exercise Setup Using Front Panel General Information General Information ‹ Date and Time Setup Using Genlink ‹ Date and Time Setup Using Front PanelSET Date and Time Adjust Display Contrast ‹ HTS Setup Using Genlink ‹ HTS Setup Using Front PanelGeneral Information NEW Generation Genlink NGG Communications Remote Annunciator Connection OptionPressure POLY3RD Appendix a Analog FunctionsThermistor Linear POLY1STPOLY1STN2 Current CalscaleAppendix B H-100 General I/O and Connector Information ‹ H-100 Analog Inputs‹ H-100 Digital Outputs ‹ H-100 Digital Inputs‹ H-100 Digital Output Functions Inlt TMP Fault Analog 6 FaultFuel PRS Fault GOV POS HI AlarmGEN Freq Fault TOT PWR HI AlarmTOT PWR LO Alarm ENG RPM HI AlarmChck V PHS ROT Fault RLY ActiveUSR Config Chck C PHS ROT‹ H-100 Connector PIN Descriptions Wire Signal DescriptionAppendix C Miscellaneous H-100 Internal ALARMS/WARNINGS Control Panel Technical Manual Control Panel Technical Manual Generac Power SYSTEMS, INC

H-100 specifications

Generac Power Systems H-100 is an innovative and robust product that has garnered attention for its reliability and performance in power generation. This generator is primarily designed for both residential and commercial applications, providing a seamless backup power solution during outages.

One of the standout features of the H-100 is its powerful engine. Equipped with a state-of-the-art gas engine, this generator can deliver up to 100 kW of power, ensuring that homes, businesses, and critical facilities remain operational even in the most challenging conditions. The engine is engineered for efficiency and longevity, reducing maintenance needs and minimizing fuel consumption.

Another significant aspect of the H-100 is its advanced Smart Management System. This technology ensures optimal power usage by intelligently distributing the electrical load among connected devices. By prioritizing essential circuits, the generator maximizes efficiency and prolongs operational time during power outages.

The H-100 also boasts a remarkable noise reduction feature. Its innovative design includes sound attenuation measures, allowing the generator to operate quietly, which is particularly beneficial in residential areas where noise pollution can be a concern. This focus on quieter operation enhances user comfort and complies with noise regulations.

Durability is a key characteristic of the Generac H-100. Constructed with high-quality materials, it is designed to withstand harsh weather conditions and heavy usage. This generator is built for longevity, providing users with reliable performance and peace of mind.

The H-100 is also equipped with a user-friendly control panel. This intuitive interface allows users to monitor the generator's performance, manage settings, and perform necessary maintenance checks easily. The integration of remote monitoring capabilities enables users to assess the generator's status from anywhere, adding an extra layer of convenience.

Lastly, Generac Power Systems offers comprehensive support and resources for H-100 users. Their commitment to customer service includes accessible informational materials, a reliable warranty program, and a national network of service professionals. This ensures that users receive the assistance they need to maintain their generators optimally.

In summary, the Generac Power Systems H-100 stands out as a reliable, efficient, and user-friendly power generation solution. With its robust engine, smart management system, noise reduction features, and durable construction, it is well-suited to meet the demands of both residential and commercial applications.