Generac Power Systems H-100 Output Functions, ‹ Other Analog Options, ‹ Spare Analog Channels

Page 7

General Information

H-100 Control Panel Technical Manual

IMMEDIATE = Alarms/Warnings with this qualifica- tion only become active immediately after the engine has started.

Sensor Failure Check

When this field is set, the input sensor is checked for short circuit or open circuit failure. Normally each of the inputs are conditioned externally to be 4- 20mA current loops. Any currents outside this range indicate a sensor failure. This will cause an alarm to occur. The alarm can be selected to shut down the engine if so desired via the next field. The alarm will be entered in the alarm log.

OUTPUT FUNCTIONS

Output functions are flags that are set/reset by the internal program to indicate a certain status, for example “Engine Running”. The Measurement Engine allows these flags to be treated as “channels” that can be made into alarms/warnings, display messages, operate real outputs and also be fed as inputs to the ILC. For example, use the “Ready To Start” output function to operate a relay by mapping it to a physical output via GenLink, or you could feed it into the ILC to do combinatorial logic.

See TABLE OF OUTPUT FUNCTIONS in appendix B.

Shutdown on Sensor Failure

When this field is set, the engine will shut down if there is a sensor failure. If the field is unchecked, the failure will just cause an alarm message to appear and the audible alarm to sound. The alarm will be entered in the alarm log.

‹OTHER ANALOG OPTIONS

Event Log

When set, the channel measurement is compared to the setpoint with either the GT or LT options. Once the condition is met (eg measurement GT setpoint) the event is logged along with a date/time stamp into the volatile memory based event log. Six other param- eters that can be chosen by the customer will also be logged. Volatile means that when power is removed from the unit, the memory will be lost.

‹SPARE ANALOG CHANNELS

Depending upon the particular configuration of your product, the following input channels may be avail- able for custom measurements:

 

Channel #

Normal function

 

 

4

Coolant level

 

 

5

Fuel Level

 

 

6

Spare

 

 

7

Throttle position

 

 

8

Oxygen sensor 0-1Vdc

 

 

9

Battery charge current 0-5Vdc

 

 

 

 

 

Analog Outputs

There are no analog outputs available for customiza- tion.

‹ANALOG SENSOR RATINGS

Typically the sensors used by the manufacturer have the following ratings:

Temperature

35 - 300 deg. F

Pressure

0 - 150 psi

5

Image 7
Contents Control Panel Technical Manual  General Hazards  Inside Front Cover Authorized Service Dealer Location‹ Customization FeaturesPanel Setup IntroductionThen Measurement Engine‹ Analog Channels ‹ Analog Maths‹ Analog Alarms ‹ Analog Sensor Ratings Output Functions‹ Other Analog Options ‹ Spare Analog ChannelsParameter Units ‹ Engine SettingsEngine Management ‹ Generator ParametersCLOSED? Starting and Stopping Sequence DiagramsVoltage Regulator Option Voltage Regulator Option ChartGovernor Speed Regulator Option Trending Governor Speed Regulator Option Chart‹ Remote Trending ILC ‹ Genlink Local Trending Setup‹ Local Trending ‹ Right Display Front Panel Display‹ Left Display Pages ‹ Left DisplayVolts SwitchAlrm Log Other Power‹ Alarms Graph HzEngine General Information Status Service Generator Diagnostics General Information EXERCISE/HTS TDN Event LOG Alarm LOGHome Control PanelAIR/FUEL Ratio Control Option Maintenance SettingsI2T Current Monitoring Option Internal Exercise Function Quiettest Setup Using GenlinkNormal Exercise Setup Using Genlink Quiettest Setup Using Front Panel General Information General Information Normal Exercise Setup Using Front Panel General Information General Information ‹ Date and Time Setup Using Front Panel ‹ Date and Time Setup Using GenlinkSET Date and Time Adjust Display Contrast ‹ HTS Setup Using Front Panel ‹ HTS Setup Using GenlinkGeneral Information Remote Annunciator Connection Option NEW Generation Genlink NGG CommunicationsLinear POLY1ST Appendix a Analog FunctionsThermistor Pressure POLY3RDCurrent Calscale POLY1STN2‹ H-100 Analog Inputs Appendix B H-100 General I/O and Connector Information‹ H-100 Digital Inputs ‹ H-100 Digital Outputs‹ H-100 Digital Output Functions GOV POS HI Alarm Analog 6 FaultFuel PRS Fault Inlt TMP FaultENG RPM HI Alarm TOT PWR HI AlarmTOT PWR LO Alarm GEN Freq FaultChck C PHS ROT Fault RLY ActiveUSR Config Chck V PHS ROTWire Signal Description ‹ H-100 Connector PIN DescriptionsAppendix C Miscellaneous H-100 Internal ALARMS/WARNINGS Control Panel Technical Manual Control Panel Technical Manual Generac Power SYSTEMS, INC

H-100 specifications

Generac Power Systems H-100 is an innovative and robust product that has garnered attention for its reliability and performance in power generation. This generator is primarily designed for both residential and commercial applications, providing a seamless backup power solution during outages.

One of the standout features of the H-100 is its powerful engine. Equipped with a state-of-the-art gas engine, this generator can deliver up to 100 kW of power, ensuring that homes, businesses, and critical facilities remain operational even in the most challenging conditions. The engine is engineered for efficiency and longevity, reducing maintenance needs and minimizing fuel consumption.

Another significant aspect of the H-100 is its advanced Smart Management System. This technology ensures optimal power usage by intelligently distributing the electrical load among connected devices. By prioritizing essential circuits, the generator maximizes efficiency and prolongs operational time during power outages.

The H-100 also boasts a remarkable noise reduction feature. Its innovative design includes sound attenuation measures, allowing the generator to operate quietly, which is particularly beneficial in residential areas where noise pollution can be a concern. This focus on quieter operation enhances user comfort and complies with noise regulations.

Durability is a key characteristic of the Generac H-100. Constructed with high-quality materials, it is designed to withstand harsh weather conditions and heavy usage. This generator is built for longevity, providing users with reliable performance and peace of mind.

The H-100 is also equipped with a user-friendly control panel. This intuitive interface allows users to monitor the generator's performance, manage settings, and perform necessary maintenance checks easily. The integration of remote monitoring capabilities enables users to assess the generator's status from anywhere, adding an extra layer of convenience.

Lastly, Generac Power Systems offers comprehensive support and resources for H-100 users. Their commitment to customer service includes accessible informational materials, a reliable warranty program, and a national network of service professionals. This ensures that users receive the assistance they need to maintain their generators optimally.

In summary, the Generac Power Systems H-100 stands out as a reliable, efficient, and user-friendly power generation solution. With its robust engine, smart management system, noise reduction features, and durable construction, it is well-suited to meet the demands of both residential and commercial applications.