Smith Cast Iron Boilers GB100W manual

Page 1

GB100IOM-7

GB100W

NATURAL OR PROPANE GAS BOILER

INSTALLATION & OPERATING

INSTRUCTIONS

DESIGNED AND TESTED ACCORDING TO A.S.M.E. BOILER AND PRESSURE VESSEL CODE, SECTION IV FOR MAXIMUM ALLOWABLE WORKING PRESSURE OF 50 PSI, 345 kPa WATER

NOTE TO INSTALLING CONTRACTOR: READ THESE INSTRUCTIONS CAREFULLY. THEY WILL SAVE YOU TIME IN ASSEMBLING BOILER PROPERLY.

WARNING: Installation and service must be performed by a qualified installer, service agency or the gas supplier in accordance with all local and national codes. Failure to comply with this warning can result in a fire or explosion causing property damage, personal injury or loss of life!

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damge, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas:

Do not try to light any appliance.

Do not touch any electrical switch. Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer,

service agency or the gas supplier.

INSTALLER, THESE INSTRUCTIONS TO BE AFFIXED ADJACENT TO THE BOILER.

CONSUMER, RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE PURPOSES.

WESTCAST, INC.

260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 FAX (413) 562-3799

In Canada: 7555 Tranmere Drive, Mississauga, Ont. L5S 1L4 (905) 672-2991 Fax (905) 672-2883

Image 1
Contents GB100W Before YOU Start ContentsBoiler Location Boiler Ratings and CapacitiesFront Clearances to Combustible ConstructionCombustible Floor Option Vent and Chimney DimensionsCombustion AIR Combustion Air Duct Sizing Vent ConnectionsChimney Inspection & Sizing Common Vent SystemsVent Dampers Heating System Piping Heating System PipingPiping For Use With Cooling Units CirculatorsPumped Blend System BypassGAS Supply Piping Equivalent Length ChartReverse Acting Aquastats Gas Pipe CapacityElectrical Power Connections Electrical WiringThermostat Installation Vent DamperFenwal/Honeywell Direct Ignition Theoriginalwire Bereplacedwith Ifanyof ItmustBereplaced Equivalent Withthisappliancemust ThermoplasticwireoritsHoneywell Continuous Pilot Ignition Multi Zone Diagram Flame Roll-out Safety Shutoff System Boiler SET UPLighting Instructions For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Instructions Dallumage Pour Votre Sécurité Lisez Avant DallumerComment Couper Ladmission DE GAZ DE Lappareil QUE Paire SI Vous Sentez UNE Odeur DE GAZTo Turn OFF GAS to Appliance Operating InstructionsQUE Faire SI Vous Sentez UNE Odeur DE GAZ Pour Votre Sécurité Lisez Avant DE Mettre EN MarcheContinuous Pilot System Boiler OperationIntermittent & Direct Ignition Systems Pilot Adjustment Boiler Checking & AdjustmentGas Pressure Adjustment Input RateBoiler Maintenance Vent System Instructions to the InstallerControls GB100 Series Repair Parts Replacement PartsSpark Ignition Honeywell Canadian Supplement Limited Lifetime Warranty For Residential Water Boilers Shortness of breath Page North ELM Street WESTFIELD, MA 01085 TEL 562-9631 FAX 413