Yeoman YM-CL5W, YM-CL8W, YM-CL8MF, YM-CL3MF, YM-CL5MF manual Troubleshooting tips, Smoke Control kit

Page 11

USER INSTRUCTIONS

16.Troubleshooting tips

16.1Stove glass blackening

This has four possible causes:

1.Incorrect use of Airwash

See User Instructions, Sections 1, 4 and 5 for the correct use of the air controls.

2.Burning unseasoned wood

See User Instructions, Section 3 to identify when wood is ready for burning.

3.Stove operated at too low a temperature

A stove pipe thermometer can identify this problem (Stovax part no 3046). The ideal working temperature range is 130°C - 250°C (270°F - 480°F). Failing to close down the Primary Air Control once the appliance has heated up to this range may cause the appliance to exceed the ideal temperature range and to over-fire. Over-firing can cause permanent damage to the appliance and invalidates your warranty. Burn with the Airwash Control fully open for approximately 20 minutes to cure this.

The problem may be caused by damping down the appliance during periods of extended burning.

4.Problems with the flue, in particular insufficient air pull. If the flue is not working efficiently the glass can blacken. A flue which has too much downdraft may be too short, needs lining, or has too many bends. This can also cause blackening of the stove glass. Contact the installer or a flue specialist for advice.

16.2Riddling Mechanism Jamming

This occurs when ash builds up under the riddling grate preventing movement. To rectify:

Lift out the riddling mechanism (see Installation Instructions, Section 5) and remove all ash.

Replace riddling mechanism when cleaning is complete.

De-ash and clean the inside of the appliance regularly to avoid build up of ash and subsequent jamming of mechanism.

16.3Glass cracking

Do not over tighten the screws on the glass clips when replacing the glass. This causes stress and the intense temperature changes can cause the glass to crack. For replacement glass contact your local Yeoman retailer.

16.4Appliance is producing tar

This can be identified by:

A very strong pungent smell shortly after the appliance is lit and heats up.

Glass blackening.

Thick, brown, sticky tar oozing from the pipe joints.

This is caused by burning damp wood and running the appliance at too low a temperature.

Use well seasoned wood and operate the appliance within the ideal temperature range.

Tar is a major cause of chimney fires. If the appliance experiences problems with tar build up consult a chimney sweep before continued use of the appliance.

16.5In the unlikely event of a problem that cannot be solved by these tips contact your installer or retailer for help.

17. SMOKE Control kit

17.1 This appliance can be modified to burn wood in a smoke control zone. For more details on the Smoke Control Kit for this appliance contact your retailer.

NOTE: These appliances have been independently tested to PD6434 and approved by DEFRA as an exempted appliance, allowing it to burn wood in Smoke Control areas when fitted with a Smoke Control Kit.

Organisations authorised to certify competence in the installation of domestic solid fuel appliances (Competent Persons Scheme):

APHC - Association of Plumbing and Heating

Contractors (Certification) Ltd.

www.aphc.co.uk

BESCA - Building Engineering Services Competence Accreditation Ltd.

www.besca.org.uk

HETAS - Heating Equipment Testing and Approval

Scheme Ltd.

www.hetas.co.uk

NAPIT - National Association of Professional Inspectors and Testers Ltd.

www.napit.org.uk

NICEIC - NICEIC Group Ltd.

www.niceic.org.uk

HETAS Approved Chimney Sweeps:

Nacs - The National Association of Chimney Sweeps www.chimneyworks.co.uk

APICS - The Association of Master Chimney Sweeps Ltd. www.apics.org

GMS - The Guild of Master Chimney Sweeps guildofmasterchimneysweeps.co.uk

11

Image 11
Contents Models YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MF Yeoman CLInstallation Appliance Commissioning Checklist User InstructionsInstallation Instructions Technical PRE-INSTALLATIONEssential Information Must be completed Appliance Commissioning ChecklistInstallation Engineer Retailer appliance was purchased fromAIR Controls User InstructionsGeneral Points Serial NumberRecommended Fuels Using the Appliance for the First TimeLighting the Appliance Burning Wood Refuel little and often for clean, efficient burningRunning The appliance Burning tips OVER-FIRING General CleaningASH Removal Extended burningCare of stove Seasonal use Cleaning GlassChimney Sweeping Smoke Control kit Troubleshooting tipsPacking List TECHNICAL SPECIFICATIONStandard Features YeomanDescription Yeoman DimensionsFlue Plate Site RequirementsFlue or Chimney Max. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.KFlue Outlet Positions Hearth DimensionsDistance of Appliance to wall Walls Next to a HearthFlue / Chimney Size PRE-INSTALLATION ChecksFlue VentilationModern Construction Homes Fitting Appliances on a boatTraditionally Built Homes Legal requirements Installation InstructionsInstalling the Appliance Top flue pipe installationDo not use a 90˚elbow to make this connection Rear flue pipe installationRemoval of Riddling Mechanism Fitting and Removal of the FirebricksFitting and Removal of the Baffle Replace in reverse order Hearth FixingMain grate Top Flue Rear Flue Co alarmsBS EN50292 and from the alarm manufacturers instructions Cast TOPRecord serial number in Appliance Commissioning CommissioningCommissioning Annual Service Fitting a NEW Door Glass Removal of the LOG GuardFitting and Removal of Firebricks Fitting and Removal of BaffleDo not over tighten the clamp as this could break the glass Fitting a new door sealHalf lock nuts Dome catch Adjusting Door Catch & HingesTo adjust the door hinge plate assembly Stove bodyYM-CL3MF Spares ListYM-CL5W YM-CL5 YM-CL3Service Records

YM-CL5W, YM-CL5MF, YM-CL8W, YM-CL8MF, YM-CL3MF specifications

The Yeoman YM-CL8MF, YM-CL3MF, YM-CL5MF, YM-CL5W, and YM-CL8W represent a series of technologically advanced and versatile machines that epitomize the modern engineering capabilities of Yeoman. These models have been designed for a range of agricultural and industrial applications, making them essential tools for farmers and businesses alike.

Starting with the YM-CL8MF, this model is known for its high performance and robust construction. It features an efficient engine that maximizes fuel efficiency while ensuring ample power for demanding tasks. The advanced hydraulic system allows for smooth operation and effective handling of attachments, making it suitable for a wide variety of applications, from heavy tillage to transportation.

The YM-CL3MF is a more compact option that does not compromise on power. It boasts a user-friendly interface and excellent maneuverability, making it ideal for smaller farms and tight spaces. Its low center of gravity enhances stability, while the durable build ensures resilience even in harsh conditions. This model is particularly favored for its agility and ease of use.

The YM-CL5MF strikes a balance between power and size, equipped with features designed for efficiency in both fieldwork and logistics. Its multifunctional capabilities allow operators to seamlessly switch between tasks such as plowing, harvesting, and loading. The advanced transmission provides smooth gear shifts, enhancing overall performance and operator satisfaction.

On the other hand, the YM-CL5W offers a versatile wheeled option that provides added flexibility in various terrains. Its presence is well-noted in both agricultural and municipal applications, as it can easily adapt to both crop and utility tasks. The outstanding traction and stability make it suitable for diverse environments, ensuring that operators can efficiently handle their workload.

Lastly, the YM-CL8W combines the features of its counterparts with enhanced power and capacity. This model is designed for heavier workloads and is equipped with cutting-edge technology to maximize productivity. It has a spacious operator platform for comfort during long working hours, along with an intuitive control system that simplifies operation and boosts efficiency.

Overall, these Yeoman models represent an impressive blend of power, efficiency, and versatility. Their innovative technologies and practical features cater to the evolving needs of users, solidifying Yeoman's reputation in the agricultural and industrial machinery market. Whether it’s for small farms or large-scale operations, these machines deliver performance that professionals can rely on.