Yeoman YM-CL5MF manual ASH Removal, Extended burning, Over-Firing, Chimney fire, General Cleaning

Page 9

USER INSTRUCTIONS

7.ASH REMOVAL

7.1Multi-fuel stove

Riddle with the tool provided (see Diagram 9).

Push/Pull to

operate

PR8728

Open Door (see Diagram 10).

PR8729

Using gloves carefully remove ashpan with the tool provided. Heat can remain long after use.

Place the ash into a Stovax Ash Caddy (Stovax Part No. 4227) or other suitable container.

Remove ash at least once every week when burning wood.

Do not place hot ash in a container made from plastic or any other combustible material.

8.Extended burning

8.1It is possible to get the appliance to burn for extended periods of time. In order to do this:

De-ash prior to final refuelling.

Set air controls to low combustion settings.

This will gradually blacken the glass but it will clear when operated at a high temperature for a short period.

Use smokeless fuel or small, thick logs.

9.OVER-FIRING

9.1Do not over-fill with fuel or run at high temperatures for long periods or over-firing can occur. If the flue pipe, flue collar or top plate glow red the appliance is over-firing. Close the air controls to reduce the temperature.

9.2Over-firing can cause permanent damage to the appliance.

10.Chimney fire

10.1If a chimney fire occurs:

Shut all air controls immediately.

Evacuate the building.

Call the fire brigade.

Do not re-enter the building until it is confirmed safe.

10.2Do not use the appliance after a chimney fire until:

a)It has been inspected by a registered installer*, confirming the appliance is safe to use.

b)The chimney system has been inspected and swept by a chimney sweep, confirming the system is structurally sound and free from obstruction**.

c)It is repaired as required before re-use. Use only genuine Stovax replacement parts to keep your appliance in safe, efficient working order.

11.GENERAL CLEANING

11.1Clean and inspect the appliance regularly, especially in periods of heavy use. Regular cleaning and maintenance will help give many years of safe use.

Allow appliance to cool thoroughly to avoid risk of burns. Clean regularly, according to level of use.

Remove the ash completely (see User Instructions, Section 7).

Check the internal components for damage. Do not use the appliance if any parts are broken or damaged. Replace damaged parts with genuine Stovax replacement parts to keep the appliance in safe, efficient working order.

In the U.K.

*Registered on the Competent Persons Scheme (GB only) see page 27 / INFO (Republic of Ireland).

**This should be done by a HETAS registered chimney sweep, see page 27, who will issue you with a certificate.

9

Image 9
Contents Models YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MF Yeoman CLInstallation Instructions Technical Appliance Commissioning Checklist User InstructionsPRE-INSTALLATION InstallationInstallation Engineer Appliance Commissioning ChecklistRetailer appliance was purchased from Essential Information Must be completedGeneral Points User InstructionsSerial Number AIR ControlsRecommended Fuels Using the Appliance for the First TimeLighting the Appliance Refuel little and often for clean, efficient burning Running The applianceBurning Wood Burning tips ASH Removal General CleaningExtended burning OVER-FIRINGCleaning Glass Chimney SweepingCare of stove Seasonal use Smoke Control kit Troubleshooting tipsStandard Features TECHNICAL SPECIFICATIONYeoman Packing ListDescription Yeoman DimensionsFlue or Chimney Site RequirementsMax. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.K Flue PlateFlue Outlet Positions Hearth DimensionsDistance of Appliance to wall Walls Next to a HearthFlue PRE-INSTALLATION ChecksVentilation Flue / Chimney SizeFitting Appliances on a boat Traditionally Built HomesModern Construction Homes Installing the Appliance Installation InstructionsTop flue pipe installation Legal requirementsDo not use a 90˚elbow to make this connection Rear flue pipe installationFitting and Removal of the Firebricks Fitting and Removal of the BaffleRemoval of Riddling Mechanism Hearth Fixing Main grateReplace in reverse order BS EN50292 and from the alarm manufacturers instructions Co alarmsCast TOP Top Flue Rear FlueCommissioning CommissioningRecord serial number in Appliance Commissioning Annual Service Fitting and Removal of Firebricks Removal of the LOG GuardFitting and Removal of Baffle Fitting a NEW Door GlassDo not over tighten the clamp as this could break the glass Fitting a new door sealTo adjust the door hinge plate assembly Adjusting Door Catch & HingesStove body Half lock nuts Dome catchYM-CL3MF Spares ListYM-CL5W YM-CL5 YM-CL3Service Records

YM-CL5W, YM-CL5MF, YM-CL8W, YM-CL8MF, YM-CL3MF specifications

The Yeoman YM-CL8MF, YM-CL3MF, YM-CL5MF, YM-CL5W, and YM-CL8W represent a series of technologically advanced and versatile machines that epitomize the modern engineering capabilities of Yeoman. These models have been designed for a range of agricultural and industrial applications, making them essential tools for farmers and businesses alike.

Starting with the YM-CL8MF, this model is known for its high performance and robust construction. It features an efficient engine that maximizes fuel efficiency while ensuring ample power for demanding tasks. The advanced hydraulic system allows for smooth operation and effective handling of attachments, making it suitable for a wide variety of applications, from heavy tillage to transportation.

The YM-CL3MF is a more compact option that does not compromise on power. It boasts a user-friendly interface and excellent maneuverability, making it ideal for smaller farms and tight spaces. Its low center of gravity enhances stability, while the durable build ensures resilience even in harsh conditions. This model is particularly favored for its agility and ease of use.

The YM-CL5MF strikes a balance between power and size, equipped with features designed for efficiency in both fieldwork and logistics. Its multifunctional capabilities allow operators to seamlessly switch between tasks such as plowing, harvesting, and loading. The advanced transmission provides smooth gear shifts, enhancing overall performance and operator satisfaction.

On the other hand, the YM-CL5W offers a versatile wheeled option that provides added flexibility in various terrains. Its presence is well-noted in both agricultural and municipal applications, as it can easily adapt to both crop and utility tasks. The outstanding traction and stability make it suitable for diverse environments, ensuring that operators can efficiently handle their workload.

Lastly, the YM-CL8W combines the features of its counterparts with enhanced power and capacity. This model is designed for heavier workloads and is equipped with cutting-edge technology to maximize productivity. It has a spacious operator platform for comfort during long working hours, along with an intuitive control system that simplifies operation and boosts efficiency.

Overall, these Yeoman models represent an impressive blend of power, efficiency, and versatility. Their innovative technologies and practical features cater to the evolving needs of users, solidifying Yeoman's reputation in the agricultural and industrial machinery market. Whether it’s for small farms or large-scale operations, these machines deliver performance that professionals can rely on.