SITE REQUIREMENTS

1.FLUE OR CHIMNEY

1.1The flue or chimney system must be in good condition.

It must be inspected by a competent person and passed for use with the appliance before installation.

Products of combustion entering the room can cause serious health risks.

1.2The following must be checked:

The construction of the masonry chimneys, flue block chimneys and connecting flue pipe system must meet the requirements of the Building Regulations.

A flexible flue liner system can be used if certified for use with solid fuel systems and installation complies with manufacturer’s instructions and Building Regulations. The flue liner must be replaced when an appliance is replaced, unless proven to be recently installed

and in good condition.

If it is necessary to fit a register plate it must conform to the Building Regulations.

The minimum height of the flue or chimney must

be 4.5m from the hearth to the top of the flue, with no horizontal sections and a maximum of 4 bends.

Bends must have angles of less than 45 degrees from the vertical.

Ensure the connecting flue pipe is kept a suitable distance from any combustible material and does not form part of the supporting structure of the building.

Make provision to remove the appliance without the need to dismantle the chimney.

Any existing flue must be confirmed as suitable for

the new intended use as defined in the Building Regulations.

The flue or chimney systems must be inspected and swept to confirm the system is structurally sound and free from obstructions**.

If the chimney is believed to have previously served an open fire it must be swept a second time within a month of regular use after installation to clear

any soot falls that may have occurred due to difference in combustion levels.

The flue exit from the building must comply with local building control rules.

Do not connect or share the flue or chimney system with another heating appliance.

1.3Do not connect to systems containing large voids or spaces over 230mm square.

1.4Suitable access must be provided to enable the collection and removal of debris.

1.5The flue must be swept and inspected when the appliance is installed.

1.6The flue draught must be checked with all windows and doors closed and any extraction fans in this, or adjoining rooms, running at maximum speed (see next section for additional ventilation requirements).

Max. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg

In the U.K.

*The design of the flue and chimney systems and products used should meet the requirements of ADJ along with any other relevant, National or European standards that may apply. Products should be specified with regard to the type of appliance, position within the building, fuels to be used and appliance operating temperatures.

**This should be done by a HETAS Approved Chimney Sweep (UK only) see page 27 / INFO registered (Republic of Ireland only) who will issue you with a certificate.

† Building Regulations Document J

Flue Plate:

Where a hearth, fireplace, flue or chimney is provided or extended (including cases where a flue is provided as part of refurbishment work), information essential to the correct appliance and use of these should be permanently posted in the building, to meet Requirement J4 of the Building Regulations (England and Wales), F3.12 (Scotland).

Additional:

A new factory made system that complies to EN 1856; Part 1 can be used providing installation is to the requirements of:

i)BS 7566 Parts 1 -4

ii)the manufacturer's instructions

iii)Building Regulations.

For a guide containing information on Chimneys and Flues contact:

The British Flue & Chimney Manufacturers’ Association,

FETA

2 Waltham Court Milley Lane Hare Hatch Reading Berkshire RG10 9TH

Tel: 0118 9403416

e-mail: info@feta.co.uk

14

Image 14
Contents Yeoman CL Models YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MFPRE-INSTALLATION Appliance Commissioning Checklist User InstructionsInstallation Instructions Technical InstallationRetailer appliance was purchased from Appliance Commissioning ChecklistInstallation Engineer Essential Information Must be completedSerial Number User InstructionsGeneral Points AIR ControlsUsing the Appliance for the First Time Recommended FuelsLighting the Appliance Burning Wood Refuel little and often for clean, efficient burningRunning The appliance Burning tips Extended burning General CleaningASH Removal OVER-FIRINGCare of stove Seasonal use Cleaning GlassChimney Sweeping Troubleshooting tips Smoke Control kitYeoman TECHNICAL SPECIFICATIONStandard Features Packing ListYeoman Dimensions DescriptionMax. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.K Site RequirementsFlue or Chimney Flue PlateHearth Dimensions Flue Outlet PositionsWalls Next to a Hearth Distance of Appliance to wallVentilation PRE-INSTALLATION ChecksFlue Flue / Chimney SizeModern Construction Homes Fitting Appliances on a boatTraditionally Built Homes Top flue pipe installation Installation InstructionsInstalling the Appliance Legal requirementsRear flue pipe installation Do not use a 90˚elbow to make this connectionRemoval of Riddling Mechanism Fitting and Removal of the FirebricksFitting and Removal of the Baffle Replace in reverse order Hearth FixingMain grate Cast TOP Co alarmsBS EN50292 and from the alarm manufacturers instructions Top Flue Rear FlueRecord serial number in Appliance Commissioning CommissioningCommissioning Annual Service Fitting and Removal of Baffle Removal of the LOG GuardFitting and Removal of Firebricks Fitting a NEW Door GlassFitting a new door seal Do not over tighten the clamp as this could break the glassStove body Adjusting Door Catch & HingesTo adjust the door hinge plate assembly Half lock nuts Dome catchSpares List YM-CL3MFYM-CL5W YM-CL3 YM-CL5Service Records

YM-CL5W, YM-CL5MF, YM-CL8W, YM-CL8MF, YM-CL3MF specifications

The Yeoman YM-CL8MF, YM-CL3MF, YM-CL5MF, YM-CL5W, and YM-CL8W represent a series of technologically advanced and versatile machines that epitomize the modern engineering capabilities of Yeoman. These models have been designed for a range of agricultural and industrial applications, making them essential tools for farmers and businesses alike.

Starting with the YM-CL8MF, this model is known for its high performance and robust construction. It features an efficient engine that maximizes fuel efficiency while ensuring ample power for demanding tasks. The advanced hydraulic system allows for smooth operation and effective handling of attachments, making it suitable for a wide variety of applications, from heavy tillage to transportation.

The YM-CL3MF is a more compact option that does not compromise on power. It boasts a user-friendly interface and excellent maneuverability, making it ideal for smaller farms and tight spaces. Its low center of gravity enhances stability, while the durable build ensures resilience even in harsh conditions. This model is particularly favored for its agility and ease of use.

The YM-CL5MF strikes a balance between power and size, equipped with features designed for efficiency in both fieldwork and logistics. Its multifunctional capabilities allow operators to seamlessly switch between tasks such as plowing, harvesting, and loading. The advanced transmission provides smooth gear shifts, enhancing overall performance and operator satisfaction.

On the other hand, the YM-CL5W offers a versatile wheeled option that provides added flexibility in various terrains. Its presence is well-noted in both agricultural and municipal applications, as it can easily adapt to both crop and utility tasks. The outstanding traction and stability make it suitable for diverse environments, ensuring that operators can efficiently handle their workload.

Lastly, the YM-CL8W combines the features of its counterparts with enhanced power and capacity. This model is designed for heavier workloads and is equipped with cutting-edge technology to maximize productivity. It has a spacious operator platform for comfort during long working hours, along with an intuitive control system that simplifies operation and boosts efficiency.

Overall, these Yeoman models represent an impressive blend of power, efficiency, and versatility. Their innovative technologies and practical features cater to the evolving needs of users, solidifying Yeoman's reputation in the agricultural and industrial machinery market. Whether it’s for small farms or large-scale operations, these machines deliver performance that professionals can rely on.