Yeoman YM-CL5MF, YM-CL8W, YM-CL5W User Instructions, General Points, Serial Number, AIR Controls

Page 4

USER INSTRUCTIONS

1.General POINTS

1.1Before use of this appliance please read these instructions fully.

The appliance must be fitted by a registered installer*, or approved by your local building control officer.

1.2All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance.

1.3Only use for domestic heating in accordance with these operating instructions.

1.4You must burn only approved fuels. Do not use with liquid fuels or as an incinerator.

1.5Appliance surfaces become very hot when in use. Use a suitable fireguard if young children, elderly or infirm persons are present.

Stovax offer firescreens, sparkguards and hearthgate systems for protection. Your Yeoman retailer can advise you about these products.

1.6Do not place photographs, TV’s, paintings, porcelain or other combustible items on the wall or near the appliance. Exposure to hot temperatures will cause damage.

1.7Extractor fans or cooker hoods must not be placed in the same room or space as this can cause appliance to emit fumes into the room.

1.8Do not obstruct inside or outside ventilation required for the safe use of this appliance.

1.9Do not make unauthorised changes to the appliance.

1.10The chimney must be swept at least once a year (see User Instructions, Section 13).

1.11Do not connect, or share, the same flue or chimney system with another appliance.

1.12This appliance is designed to be used with the doors shut.

SERIAL NUMBER

1.13This number is required when ordering spare parts or making warranty claims. It is found on the appliance data plate.

‡In the U.K. these products must conform to the latest edition of BS 8423, Fireguards for use with solid fuel appliances.

If appliance is operating unattended they must conform to the latest edition of BS 3248.

*Registered on the Competent Persons Scheme (GB only) see page 26 / INFO (Republic of Ireland).

Data Plate

PR8745

The data plate is found on a swing out data plate located on the back of the stove on the left hand side (see Diagram 1).

AIR CONTROLS

Triple Air Systems

This Yeoman appliance has a triple air system, providing cleaner burning and greater efficiency and control (see Diagram 2).

1)Airwash - air drawn over the window cleans the glass. The source of Primary Combustion air when burning wood.

2)Primary Air - for use with solid fuel and when lighting wood fires.

3)Cleanburn - secondary air is preheated through a heat exchanger to combust unburned hydrocarbons, providing a cleaner and more efficient burn.

PR8702

For Air Controls see the diagram over.

Use the tool provided to operate the air controls.

Do not place tool on hot surfaces (e.g. top of stove).

4

Image 4
Contents Yeoman CL Models YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MFAppliance Commissioning Checklist User Instructions Installation Instructions TechnicalPRE-INSTALLATION InstallationAppliance Commissioning Checklist Installation EngineerRetailer appliance was purchased from Essential Information Must be completedUser Instructions General PointsSerial Number AIR ControlsUsing the Appliance for the First Time Recommended FuelsLighting the Appliance Running The appliance Refuel little and often for clean, efficient burningBurning Wood Burning tips General Cleaning ASH RemovalExtended burning OVER-FIRINGChimney Sweeping Cleaning GlassCare of stove Seasonal use Troubleshooting tips Smoke Control kitTECHNICAL SPECIFICATION Standard FeaturesYeoman Packing ListYeoman Dimensions DescriptionSite Requirements Flue or ChimneyMax. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.K Flue PlateHearth Dimensions Flue Outlet PositionsWalls Next to a Hearth Distance of Appliance to wallPRE-INSTALLATION Checks FlueVentilation Flue / Chimney SizeTraditionally Built Homes Fitting Appliances on a boatModern Construction Homes Installation Instructions Installing the ApplianceTop flue pipe installation Legal requirementsRear flue pipe installation Do not use a 90˚elbow to make this connectionFitting and Removal of the Baffle Fitting and Removal of the FirebricksRemoval of Riddling Mechanism Main grate Hearth FixingReplace in reverse order Co alarms BS EN50292 and from the alarm manufacturers instructionsCast TOP Top Flue Rear FlueCommissioning CommissioningRecord serial number in Appliance Commissioning Annual Service Removal of the LOG Guard Fitting and Removal of FirebricksFitting and Removal of Baffle Fitting a NEW Door GlassFitting a new door seal Do not over tighten the clamp as this could break the glassAdjusting Door Catch & Hinges To adjust the door hinge plate assemblyStove body Half lock nuts Dome catchSpares List YM-CL3MFYM-CL5W YM-CL3 YM-CL5Service Records

YM-CL5W, YM-CL5MF, YM-CL8W, YM-CL8MF, YM-CL3MF specifications

The Yeoman YM-CL8MF, YM-CL3MF, YM-CL5MF, YM-CL5W, and YM-CL8W represent a series of technologically advanced and versatile machines that epitomize the modern engineering capabilities of Yeoman. These models have been designed for a range of agricultural and industrial applications, making them essential tools for farmers and businesses alike.

Starting with the YM-CL8MF, this model is known for its high performance and robust construction. It features an efficient engine that maximizes fuel efficiency while ensuring ample power for demanding tasks. The advanced hydraulic system allows for smooth operation and effective handling of attachments, making it suitable for a wide variety of applications, from heavy tillage to transportation.

The YM-CL3MF is a more compact option that does not compromise on power. It boasts a user-friendly interface and excellent maneuverability, making it ideal for smaller farms and tight spaces. Its low center of gravity enhances stability, while the durable build ensures resilience even in harsh conditions. This model is particularly favored for its agility and ease of use.

The YM-CL5MF strikes a balance between power and size, equipped with features designed for efficiency in both fieldwork and logistics. Its multifunctional capabilities allow operators to seamlessly switch between tasks such as plowing, harvesting, and loading. The advanced transmission provides smooth gear shifts, enhancing overall performance and operator satisfaction.

On the other hand, the YM-CL5W offers a versatile wheeled option that provides added flexibility in various terrains. Its presence is well-noted in both agricultural and municipal applications, as it can easily adapt to both crop and utility tasks. The outstanding traction and stability make it suitable for diverse environments, ensuring that operators can efficiently handle their workload.

Lastly, the YM-CL8W combines the features of its counterparts with enhanced power and capacity. This model is designed for heavier workloads and is equipped with cutting-edge technology to maximize productivity. It has a spacious operator platform for comfort during long working hours, along with an intuitive control system that simplifies operation and boosts efficiency.

Overall, these Yeoman models represent an impressive blend of power, efficiency, and versatility. Their innovative technologies and practical features cater to the evolving needs of users, solidifying Yeoman's reputation in the agricultural and industrial machinery market. Whether it’s for small farms or large-scale operations, these machines deliver performance that professionals can rely on.