Viper FANG 20T-EU Before Machine Start-Up, English, Pre-Operationchecks, Mounting The Squeegee

Page 13
BEFORE MACHINE START-UP

ENGLISH

USER MANUAL

 

 

 

 

BEFORE MACHINE START-UP

PRE-OPERATION CHECKS

1.Sweep or dust mop the surface to be cleaned.

2.Check battery meter to make sure batteries are fully charged. (see BATTERY CHARGING)

3.Check that squeegee is properly installed.

4.Check that brush / pad is properly installed.

INSTALLING PAD DRIVER OR BRUSH

1.Ensure that the machine is turned off.

2.Lower brush head assembly to the floor by stepping on the foot pedal and pushing pedal forward.

3.Tilt the machine backward to access the drive motor hub.

NOTE

Remove the squeegee assembly prior to tilting the machine backwards. It makes the process faster and easier.

WARNING!

Do not keep the machine tilted back for a long time. This could cause battery acid to leak from the batteries.

4.If using a pad driver, first attach the appropriate pad to the pad driver surface.

5.Mount the pad driver or brush to the drive motor hub by lining up the three studs with the three holes in the drive motor hub. Once in the holes, rotate the driver toward the spring clip to lock driver into place.

MOUNTING THE SQUEEGEE

1.Pull back on the squeegee lift lever to raise the squeegee bracket up.

2.Loosen the two knobs on the squeegee and slide the squeegee into the slots at the rear of the squeegee bracket. (the wheels on the squeegee point to the back)

3.Tighten the knobs securely.

FILLING THE SOLUTION TANK

1.The Fang 20-EU / Fang 20T-EU can be filled in two different locations:

a.Front fill area for use with a hose or a bucket.

b.Rear fill area for use with a hose only.

2.Determine which fill area you would like to use to fill the machine with water.

3.Fill solution tank with up to 48 liters of water. (water temperature should not exceed 40° C) The clear tube in the back left of the machine has gallon markers to help determine the water level in the solution tank.

NOTE

If you are filling the solution tank with a bucket, make sure the bucket is clean. This will prevent debris from clogging the lines or solenoid.

WARNING!

Do not put any flammable materials into solution tank. This can cause an explosion or a fire. Only use reco- mmended cleaning chemicals. Contact your janitorial supply distributor for recommendations on proper ch- emicals.

12

SCRUBBERS FANG20-EU / FANG20T-EU

82089E(1)2009-04A

Image 13
Contents 1-21 FANG 20-EU FANG 20T-EUENGLISH TABLE OF CONTENTS82089E1200904A SCRUBBERS FANG20-EU / FANG20T-EUMANUAL PURPOSE AND CONTENTS INTRODUCTIONHOW TO KEEP THIS MANUAL TARGETSPARE PARTS AND MAINTENANCE UNPACKING/DELIVERYOTHER REFERENCE MANUALS CHANGES AND IMPROVEMENTSSYMBOLS SAFETYGENERAL INSTRUCTIONS ENGLISH82089E12009-04A ENGLISHSCRUBBERS FANG20-EU / FANG20T-EU MACHINE DESCRIPTION MACHINE STRUCTUREENGLISH TECHNICAL DATA ACCESSORIES/OPTIONSENGLISH ENGLISHENGLISH WIRING DIAGRAM FANG20-EUColour codes 82089E12009-04AENGLISH WIRING DIAGRAM FANG20T-EUColour codes SCRUBBERS FANG20-EU / FANG20T-EUBATTERY CHARGER SETTING BATTERY INSTALLATIONENGLISH 82089E12009-04AFILLING THE SOLUTION TANK INSTALLING PAD DRIVER OR BRUSHBEFORE MACHINE START-UP ENGLISHENGLISH MACHINE START AND STOP82089E12009-04A SCRUBBERS FANG20-EU / FANG20T-EUBattery discharge during operation Solution flow adjustmentENGLISH SRUBBERS FANG20-EU / FANG20T-EUENGLISH WHILE OPERATING MACHINE82089E12009-04A SCRUBBERS FANG20-EU / FANG20T-EUDRAINING THE SOLUTION CLEAN TANK DRAINING THE RECOVERY DIRTY TANKTANK DRAINING ENGLISHENGLISH BATTERY CHARGING82089E12009-04A SCRUBBERS FANG20-EU / FANG20T-EUDAILY MAINTENANCE MAINTENANCEWEEKLY MAINTENANCE MONTHLY MAINTENANCEBRUSH/PAD CLEANING SQUEEGEE BLADE CHECK AND REPLACEMENTENGLISH 82089E12009-04APROBLEM BASIC TROUBLESHOOTINGCAUSE SCRUBBERS FANG20-EU / FANG20T-EUREMARKS SCRAPPINGENGLISH 82089E12009-04A