Wayne 352205-001 warranty Troubleshooting Chart, Symptom Possible Causes, Corrective Action

Page 6

Operating Instructions and Parts Manual

Troubleshooting Chart

Symptom

Possible Cause(s)

Pump won’t run

1. Connections not secure

 

2. Low or defective battery

 

3. Float switch stuck

 

4. Defective or blown fuse

Corrective Action

1.Check all connections

2.Check battery and replace if low or defective

3.Make sure nothing is interfering with operation of switch

4.Check internal fuse located inside the control box. Pull the charger from the wall outlet and remove. If the fuse is blown, replace it with a 20 amp automotive type fuse

Motor hums but

1. Defective battery

pump won’t run

2. Impeller is locked

1.Check battery and replace if low or defective

2.Unplug pump, remove screen, and check to see if impeller is free to turn. If impeller is locked, remove the 7 screws on the bottom of the pump to release the housing around the impeller. Remove the obstruction. Reassemble pump and reconnect

Pump runs but

1. Check valve missing or improperly

pumps very little

installed

or no water

 

 

2. Obstruction in discharge pipe

 

3. Discharge pipe length and/or

 

height exceeds capacity of pump

 

4. Low or defective battery

1.Check to make sure check valves installed between primary pump discharge and Backup Sump Pump are functioning properly

2.Check for obstruction and clear if necessary

3.If discharge is too high, a separate line may be required with a lower discharge height

4.Check battery and replace if low or defective

Pump cycles too 1. Check valve problem

1. Check to make sure check valves installed between primary

frequently

pump discharge and Backup Sump Pump are functioning

 

properly

www.waynepumps.com

6

Image 6
Contents Battery Information Safety GuidelinesGeneral Safety Information DescriptionInstallation Pump InstallationMethod 1 Preferred Method Control Box Installation OperationMethods 1 Maintenance BatteriesTroubleshooting Chart Symptom Possible CausesCorrective Action For Replacement Parts, call Part No. Description Number QtyLimited Warranty Information sur la batterie Directives de SécuritéGénéralités sur la Sécurité DéballageMontage Installation de la pompeInformation sur la batterie Suite Méthode 1 de choixMontage Suite Méthode11 Fr Méthodes 1 et Installation de la boîte de contrôleFonctionnement 12 FrEntretien 13 FrGuide de Dépannage Symptôme Causes Possibles Mesures Correctives14 Fr Numéro Réf. Description De pièce Qté 15 FrGarantie Limitée 16 FrInformaciones Generales de Seguridad DescripciónMedidas de Seguridad Información sobre la bateríaInstalación de la bomba Información sobre laInstalación 18 SpMétodo 1 se prefiere Método19 Sp Instalación de la caja de control FuncionamientoMétodos 1 y 20 SpMantenimiento 21 SpGuía de diagnóstico de averías 22 SpNo. de Número Descripción De pieza Ctd 23 SpGarantía Limitada 24 Sp