Emerson UVC120, MAN -0016-00 manual Unit I General Information

Page 7

Unit I GENERAL INFORMATION

DESCRIPTION

The UVC120 Flam e Detectors combined with the U1F, U2F or U4F-UV Fire Controller provide fast, reliable flam e detection in a wide variety of applications. The microprocessor based controllers sim ultaneously monitor up to four ultraviolet (UV) detectors to provide maxim um operating flexibility at minim um expense. The Autom atic Visual Integrity (vi) feature provides a continuous check of optical surfaces, sensitivity and electronic circuitry of the detector/controller system . Autom atic fault identification monitors system operation and provides a digital display of system status using a numerical code. Controller response includes actuation of relays for direct control of field response devices and a full array of faceplate indicators. Other features include individual channel and area identification, "voting" capability and manual vi testing.

FEATURES

<Non-Intrusive testing activated by magnets

<Instantaneous response to ultraviolet radiation

<Autom atic and manual Visual Integrity (vi) testing

<Adjustable sensitivity and tim e delay

<All autom atic test functions perform ed with the system on line

<Autom atic fault identification

<Individual channel identification with voting options

<Latching Area LEDs identify the area responding to fire

<Microprocessor-based controller is easily field-program m able.

<Two digital displays, one bar graph display and high intensity LEDs indicate system status inform ation

<Relay outputs are field adjustable as latching or non-latching

<Alarm relays are program m able for norm ally energized or de-energized operation

<Individual detector output (count rate) can be visually monitored on the digital display

<Two 4-20mA current outputs (U2F and U4F). One 4-20mA output on U1F

<Conduit seals recomm ended to prevent moisture dam age but not required

CONTROLLER SPECIFICATIONS

<Operating Voltage:

24 Volts DC nominal. 18 to 32Vdc.

<Power Consumption (controller only):

2.4 watts nom inal, 4.4 watts maxim um .

100 mA nom inal, 180 mA maxim um at 24 Volts DC.

Maxim um startup current is 1.5 Am peres for 10 m illiseconds. Power supplies with fold back current lim iting are not recom m ended.

<Maximum Ripple:

Ripple should not exceed 5 Volts peak-to-peak. The sum of DC plus ripple must be $18 Vdc and #32 Vdc

<Temperature Range:

Operating:

-40ºC to +85ºC

(-40ºF to +185ºF)

Storage:

-55ºC to +150ºC

(-65ºF to +302ºF)

- 1 -

Image 7
Contents Ultraviolet Fire Detection System Page Page Page Table of Contents Unit V Maintenance Unit I General Information Detector Specifications Dimensions Basic Operation Controller Controller Faceplate Description Relay Outputs OutputsCurrent Outputs Automatic Diagnostics and Fault Identification External ResetProgramming Options Petroleum Products Handling Unit II UV Fire DetectionDetector System ApplicationGaseous Fuel Handling Detector Sensitivity Spectral Sensitivity RangeOther Processes System Sensitivity Cone of VisionInstallation General Wiring Requirements Unit III System InstallationController Wiring Page W iring for U1F-UV with Non-Isolated Current Output W iring for U1F-UV with Isolated Current Output W iring for U2F-UV with Non-Isolated Output W iring Diagram for U2F-UV with Isolated Current Output W iring for U4F-UV with Non-Isolated Current Output W iring for U4F-UV with Isolated Current Output Position and Density of Detectors DIP Switch SettingsMounting the Detector U2F and U4F Controller Sensitivity AdjustmentChannel Selection U1F, U2F and U4FRelay Outputs ENERGIZED/DE-ENERGIZED Relay Outputs LATCHING/NON-LATCHINGExample Page Relay Settings Time Delay for Area AlarmsCheckout Procedure Startup ProcedureUnit IV System Operation Manual Check Procedure Normal Operation Fire Response Alternate Test ProcedureCurrent Output Situation Main Menu Special Function Menu Error Check Mode Err ChcCurrent Calibration Mode CuC Device Repair and Return Unit V MaintenanceRoutine Maintenance TroubleshootingPage Appendices B lis h ed in Accordance with E1A Standard Appendix B Procedure For Activating Reed Switches Appendix C Record Of Dip Switch Settings Appendix D Common Ultra-Violet Absorbing Gases AWG #20 AWG #18 AWG #16 AWG #14 AWG #12 AWG #10 AWG #8 Appendix E Wire Resistance In Ohms

0016-00, UVC120, MAN -0016-00 specifications

The Emerson MAN-0016-00, UVC120, 0016-00 is a state-of-the-art device designed to meet the demands of modern industrial and commercial applications. This advanced model showcases Emerson’s commitment to innovation, providing users with reliable performance and cutting-edge technology.

One of the key features of the Emerson MAN-0016-00 is its superior control capabilities. Equipped with sophisticated algorithms, this device ensures precise and adaptable control over various processes, improving efficiency and productivity in operations. Users benefit from enhanced responsiveness to changing conditions, allowing for quick adjustments that lead to optimized performance.

Another noteworthy technology integrated into the UVC120 is its advanced user interface. The device boasts a highly intuitive control panel that facilitates easy navigation and management of settings. This user-friendly design minimizes the learning curve for operators, ensuring that they can quickly familiarize themselves with its functions. The display provides clear, real-time feedback, enabling users to monitor system performance effortlessly.

The Emerson MAN-0016-00 is also characterized by its robust construction. Designed to endure harsh environmental conditions, this model is built with durable materials that enhance its longevity and reliability. It is resistant to various industrial contaminants, ensuring consistent operation even in challenging settings.

Energy efficiency is a hallmark of the UVC120 model. By employing innovative power management technologies, it significantly reduces energy consumption without compromising performance. This emphasis on sustainability not only lowers operational costs for users but also aligns with global efforts to minimize environmental impact.

Moreover, the Emerson MAN-0016-00 incorporates advanced safety features that prioritize user protection. These include integrated alarms and emergency shut-off mechanisms that respond to detected anomalies, enhancing overall workplace safety. The design also adheres to international safety standards, ensuring compliance and peace of mind for users.

In conclusion, the Emerson MAN-0016-00, UVC120, 0016-00 stands out as an exemplary model in the field of industrial technology. Its combination of precision control, user-friendly interface, robust construction, energy efficiency, and safety features make it an ideal choice for various applications. As industries continue to evolve, devices like this play a crucial role in enhancing performance, safety, and sustainability across the board.