O2 Innovations pmn manual Target Features

Page 5

TARGET Series

ENMET Corporation

￿ENMET either repairs or replaces damaged equipment and invoices the carrier to the extent of the liability coverage, usually $100.00. Repair or replacement charges above that value are your company’s responsibility.

￿The shipping company may offer optional insurance coverage. ENMET only insures shipments with the shipping company when asked to do so in writing by our customer. If you need your shipments insured, please forward a written request to ENMET Customer Service.

Regarding Shortages

If there are any shortages or questions regarding this shipment, please notify ENMET Customer Service within 5 days of receipt at the following address:

ENMET Corporation

680 Fairfield Court

Ann Arbor, MI 48108

734-761-1270 734-761-3220 Fax

1.3 Check Order

Check, the contents of the shipment against the purchase order. Verify that the TARGET Series instrument is received as ordered. Follow the procedure outlined in paragraph 2.0 to determine your instrument configuration. If there are accessories on the order, ascertain that they are present. Check the contents of calibration kits. Notify ENMET customer service personnel of any discrepancy immediately.

1.4 Serial Numbers

Each TARGET Series instrument is serialized. These numbers are on tags on the equipment and are on record in an ENMET database.

2.0TARGET Features

2.1Sensors

The TARGET Series by ENMET Corporation is a multi-gas portable instrument that may be configured with one to six sensors. Sensors include:

Oxygen

Flammable

Broad Range Hydrocarbon Toxic MOS (Metallic Oxide Semiconductor) Sensor

Carbon monoxide

Hydrogen sulfide

Ammonia, Sulfur dioxide, Chlorine and many more will be available soon.

2.2Other features include:

Metal enclosure for improved durability

RFI resistant design

Four line display with backlight

Push-button calibration procedure

Programmable combustible sensor

Optional internal sampling pump

Audible alarms

Visual alarm for each sensor

Dual alarm levels for Toxic and Combustible gases

Oxygen deficiency and enrichment alarms

Maximum and Minimum tracking of gas readings

Peak hold

Latching alarms

STEL and TWA alarms

Datalogging

Calibration reminder

Intrinsically safe by design. CSA approved.

CE approval pending

2

Image 5
Contents Enmet Corporation Target SeriesTable of Contents List of Figures and Tables Regarding Damaged Shipments UnpackTarget Features Horn ON/OFF Button Select Button Menu Button Gasket Visual Alarms Display Charging PortInstrument Operation Example Power Down DisplayLocations and Data logging Turning the Instrument On and OffExample Display, Charging Complete Charging the BatteryExample Display, Battery Charging Alarms Battery LifeInstantaneous Gas Alarm STEL/TWA AlarmsExample Display, Auto-Zero from Pop-Up Menu Pop-Up MenuExample Pop-Up Menu Example Display, Combustible Gas Example Display of Calibration StatusProgrammed Flammable Gas Coefficients Internal Sampling Pump Example Display, Internal Pump StatusExample Display of Date, Time, Battery Level Date/Time/Battery InformationAlarms Values Example Display of Alarm ValuesStel Values Min/Max ValuesTWA Values Standard Maintenance Menu Maintenance OperationsRecommendations CalibrationApplying Span Gas Zero AdjustCalibration Adapter, Reactive Gases Calibration Adapter, BRH 04834-002Example Display of Advanced Maintenance Menu Advanced Maintenance Menu, Software 4.94 versionExample Display of Advanced Calibration Menu Example Display of BRH CalibrationExample Display Changing Password Example Display of Set Alarm MenuExample Display while Setting Clock and Chirp interval Set Battery Type Example Display Setting Battery TypeExample Display of Set Operation Menu Set Operation Menu4a.1 Calibration 4a Advanced Maintenance Menu, Software 6.0 version4a.2 Setting Instantaneous Alarms 4a.4 Internal Pump Calibration 4a.3 Enable SensorsPCB Replacing Battery PackRemove shorting clip Replacing SensorsEnmet Part No Description Instrument InformationElement Specification Target SpecificationsDefault Configuration Default Alarm and ConfigurationsDefault Alarm Basic Operation Menu Flow DiagramsTarget Menu Quick Reference Enter any calibration procedure from above Advanced Operation Menu BRH Advanced Maintenance Menu, Software 6.0 version Symptom Possible Cause Action TroubleshootingWarranty PO Box Fairfield Court Ann Arbor, Michigan 734.761.1270 Fax Returning an Instrument for RepairRepair Return Form