NOTE: The default CAL Reminder period is set to NEVER.

Set the calibration reminder period as follows:

1.Enter the SETUP MENU per Section 3.5.1. If necessary, press ESC until MENU appears above F2.

2.Use the ▲▼ buttons to select CAL RE-

MINDER PERIOD. Press ENTER to dis- play the Cal Reminder Period Menu.

3.Use the ▲▼ buttons to select the desired time period.

4.Press ENTER to save selection and return to the SETUP MENU or ESC to revert to the previous setting.

NOTE: The date and time settings must be correct to get ac- curate cal reminders.

3.5.13 Inactivity Timeout

The analyzer can be placed in an inactivity timeout period of None, 30 or 60 minutes. With this time period set the analyzer will automatically shut off if there have been no button pushes made in the set period of time. The analyzer will not turn off if the CO value is greater than 50 ppm or the O2 value is less than 16%.

NOTE: The default set time is NONE which will not allow the ana- lyzer to automatically turn off.

Set the Inactivity Timeout Period as follows:

1.Enter the SETUP MENU per Section 3.5.1. If necessary, press ESC until MENU appears above F2.

2.Use the ▲▼ buttons to select INACTIVITY

TIMEOUT. Press ENTER to display the

Inactivity Timeout Menu.

3.Use the ▲▼ buttons to select the desired timeout period.

4.Press ENTER to save the selection and re- turn to the SETUP MENU or ESC to revert to the previous setting.

Fyrite® INSIGHT

3.5.14 Post-Purge Period

The analyzer can be setup to purge the sensors following the combustion test. It can be programmed to purge for None, 5 seconds, 1, 5, or 10 min- utes.

Set the Post-Purge Period as follows:

1.Enter the SETUP MENU per Section 3.5.1. If necessary, press ESC until MENU ap- pears above F2.

2.Use the ▲▼ buttons to select POST-PURGE PERIOD. Press ENTER to display the Post- Purge Period Menu.

3.Use the ▲▼ buttons to select the desired time period.

4.Press ENTER to save the selection and re- turn to the SETUP MENU or ESC to revert to the previous setting.

3.5.15 Date Format

The date format options and the clock settings are interdependent.

MM/DD/YY format - Used with a 12 hour time clock. This set up menu

includes an AM/PM option.

DD/MM/YY format - Used with a 24 hour time clock.

Change the date format as follows:

1.Enter the SETUP MENU per Section 3.5.1. If necessary, press ESC until MENU ap- pears above F2.

2.Use the ▲▼ buttons to select DATE FOR- MAT. Press ENTER to display the Date Format Menu.

3.Use the ▲▼ buttons to select the desired date format.

4.Press ENTER to save the selection and re- turn to the SETUP MENU or ESC to revert to the previous setting.

18

Instruction 24-9460

 

Instruction 24-9460

19

Image 12
Contents Fyrite Insight Table of Contents Introduction Fyrite InsightFyrite Insight Features & Benefits Technical Characteristics Operational OverviewSetting UP the Analyzer PowerConnecting the Probe Hose & Thermo- couple Preliminary StepsInsight Setup Mode Entering SetupTemperature Units Front Panel Push ButtonsPressure Units Clock5 O2 Reference Print PressureUsername 9 Run/Hold FormatLanguage Selection Button SoundCAL Reminder Period Inactivity Timeout Post-Purge PeriodDate Format Analyzer Power On & Warm Up OperationOperating Tips Fuel SelectionSampling Point Performing a Combustion TestMaking a Draft / Pressure Measurement Temperature Measurement Saving Test DataEnding a Combustion Test Emptying the Water TrapPowering OFF the Analyzer & Purging Low Battery AlarmMemory Fyrite User Software Installation Printing Test DataPress the Print F1 button to begin print- ing Windows Vista Operating System Calibration & Maintenance Fyrite User Software DescriptionSmart Sensors Starting a CalibrationPressure Sensor Calibration Materials RequiredProcedure TS-Zero ProcedureStack Calibration TS-Span Procedure TA-Zero ProcedureAir Calibration Material RequiredTA-Span Procedure CO Sensor CalibrationMaintenance Fyrite Insight Disassembly O2 Sensor Replacement Water Trap / FilterCO Sensor Replacement Thermocouple ReplacementTools Required Gas Pump Replacement Cleaning the ProbeError Messages Parts & Tools RequiredDiagnostics Screen Status ScreenService Centers United States PennsylvaniaCanada MéxicoHeadquarters Hunt Valley Circle, New Kensington, PA

INSIGHT specifications

Bacharach INSIGHT is a cutting-edge platform designed for HVAC professionals and building management teams, providing real-time insights and analytics for optimal system performance. Offering a seamless integration of hardware and software, INSIGHT enhances operational efficiency by transforming traditional data management paradigms.

One of the standout features of Bacharach INSIGHT is its user-friendly interface, which enables users to visualize data in an easily digestible format. The platform presents key metrics, historical trends, and system alerts, empowering users to make informed decisions quickly. This accessibility is crucial for technicians and managers who need to identify potential issues before they escalate, ensuring systems run smoothly and effectively.

Another significant characteristic of Bacharach INSIGHT is its advanced data analytics capabilities. The platform leverages machine learning algorithms to analyze performance data, identify patterns, and predict maintenance needs. This proactive approach minimizes downtime and extends the lifespan of HVAC systems, resulting in cost savings for organizations.

INSIGHT also incorporates IoT technologies, allowing for real-time data collection from various connected devices across an HVAC system. This integration ensures that users have access to accurate and timely information, facilitating immediate responses to any irregularities. The use of cloud technology enables data storage and access from anywhere, promoting collaboration among team members and stakeholders.

The platform is designed with scalability in mind, accommodating small businesses with singular HVAC units as well as large enterprises with complex, multi-site systems. This flexibility means that as organizations grow, Bacharach INSIGHT can adapt to their changing needs without requiring extensive modifications.

Furthermore, user customization options allow for tailored dashboards and alerts, ensuring that each team can focus on the most relevant metrics for their operations. This adaptability contributes to improved user experience, enhancing system usability and engagement.

In summary, Bacharach INSIGHT combines intuitive design, powerful analytics, IoT integration, and scalability to redefine HVAC management. By equipping users with actionable insights and fostering proactive maintenance practices, INSIGHT positions organizations to optimize their energy use, reduce costs, and improve overall system reliability. This innovative platform is pioneering a new era for HVAC professionals, facilitating smarter building management with robust, real-time analytics.