Bacharach INSIGHT manual Username, 9 Run/Hold Format

Page 10

Fyrite® INSIGHT

lated data no matter what zoom level has been selected. Select the desired zoom level as follows:

1.Enter the Setup Menu per Section 3.5.1. If necessary, press ESC until MENU appears above F2.

2.From the SETUP MENU, use the ▲▼

buttons to select ZOOM. Press ENTER to display the Zoom Menu.

3.Use the ▲▼ buttons to select the desired zoom level.

4.Press ENTER to save the selection and dis- play the SETUP MENU or ESC to revert to the previous setting.

3.5.8 Username

The name of the user or owner (e.g. company name, address, phone num- ber) can be stored in memory by manually entering up to three lines of text, with each line containing up to 20 alphanumeric characters. This information will appear at the top of each printout, until it is cleared or new information is entered.

Username Information can be entered as follows:

1.Enter the Setup Menu per Section 3.5.1. If necessary, press ESC until MENU appears above F2.

2.Use the ▲▼ buttons to select USERNAME.

Press ENTER to display the most recently saved information.

3.Use the ▲▼ buttons to select the line of in- formation which you would like to edit and press ENTER. A single cursor will appear denoting the character you are changing.

4.Use the ▲▼ buttons to scroll the the list of alphanumeric characters and the ◄► but- tons to move across the screen.

5.Press ENTER to save the selection or ESC to revert to the previous input.

Fyrite® INSIGHT

6.Repeat Steps 3-5 to edit the remaining lines.

7.Once the input is complete, use the ▲▼ buttons to select EDIT COMPLETE.

8.Press ENTER to accept the entered information or ESC to revert to the previous information and display the SETUP MENU.

Helpful Hint: Use the Fyrite® user software to upload this informa- tion from your computer.

To Clear a Username proceed as follows:

1.Enter the SETUP MENU per Section 3.5.1. If necessary, press ESC until MENU appears above F2.

2.Use the ▲▼ buttons to select USERNAME. Press ENTER to dis- play the most recently saved information.

3.Clear the information by selecting the CLEAR option (F3).

3.5.9 Run/Hold Format

Fyrite INSIGHT test data is located in the Run/Hold screen. By press- ing the RUN/HOLD key, you should hear the pump running and see the word RUN at the upper-left hand corner of the display. The instrument is continuously measuring and calculating the data that is shown in the Run/Hold screen. Press the RUN/HOLD key again. The pump should stop running and the word HOLD should be shown at the upper-left hand cor- ner of the display. The instrument will now show the last measured and calculated data taken before the instrument was placed in HOLD. Use the ▲▼ buttons to scroll through the complete list of measured and calculated values when the instrument is running or in the HOLD mode.

The order in which data appears in the RUN/HOLD screen is as follows:

O2

=

Oxygen

CO

=

Carbon Monoxide

Eff

=

Combustion Efficiency

CO2

=

Carbon Dioxide

T-STK

=

Stack Temperature

T-AIR

=

Ambient/Primary Air Temperature

EA

=

Excess Air

CO(n)

=

Carbon Monoxide content referenced to an Oxygen

 

 

percentage

NOTE: (n) is the current O2 Reference selected.

14

Instruction 24-9460

 

Instruction 24-9460

15

Image 10
Contents Fyrite Insight Table of Contents Introduction Fyrite InsightFyrite Insight Features & Benefits Technical Characteristics Operational OverviewConnecting the Probe Hose & Thermo- couple Setting UP the AnalyzerPower Preliminary StepsInsight Temperature Units Setup ModeEntering Setup Front Panel Push Buttons5 O2 Reference Pressure UnitsClock Print PressureUsername 9 Run/Hold FormatButton Sound Language SelectionCAL Reminder Period Post-Purge Period Inactivity TimeoutDate Format Operating Tips Analyzer Power On & Warm UpOperation Fuel SelectionSampling Point Performing a Combustion TestMaking a Draft / Pressure Measurement Ending a Combustion Test Temperature MeasurementSaving Test Data Emptying the Water TrapLow Battery Alarm Powering OFF the Analyzer & PurgingMemory Printing Test Data Fyrite User Software InstallationPress the Print F1 button to begin print- ing Windows Vista Operating System Smart Sensors Calibration & MaintenanceFyrite User Software Description Starting a CalibrationPressure Sensor Calibration Materials RequiredTS-Zero Procedure ProcedureStack Calibration Air Calibration TS-Span ProcedureTA-Zero Procedure Material RequiredTA-Span Procedure CO Sensor CalibrationMaintenance Fyrite Insight Disassembly O2 Sensor Replacement Water Trap / FilterThermocouple Replacement CO Sensor ReplacementTools Required Error Messages Gas Pump ReplacementCleaning the Probe Parts & Tools RequiredDiagnostics Screen Status ScreenCanada Service CentersUnited States Pennsylvania MéxicoHeadquarters Hunt Valley Circle, New Kensington, PA

INSIGHT specifications

Bacharach INSIGHT is a cutting-edge platform designed for HVAC professionals and building management teams, providing real-time insights and analytics for optimal system performance. Offering a seamless integration of hardware and software, INSIGHT enhances operational efficiency by transforming traditional data management paradigms.

One of the standout features of Bacharach INSIGHT is its user-friendly interface, which enables users to visualize data in an easily digestible format. The platform presents key metrics, historical trends, and system alerts, empowering users to make informed decisions quickly. This accessibility is crucial for technicians and managers who need to identify potential issues before they escalate, ensuring systems run smoothly and effectively.

Another significant characteristic of Bacharach INSIGHT is its advanced data analytics capabilities. The platform leverages machine learning algorithms to analyze performance data, identify patterns, and predict maintenance needs. This proactive approach minimizes downtime and extends the lifespan of HVAC systems, resulting in cost savings for organizations.

INSIGHT also incorporates IoT technologies, allowing for real-time data collection from various connected devices across an HVAC system. This integration ensures that users have access to accurate and timely information, facilitating immediate responses to any irregularities. The use of cloud technology enables data storage and access from anywhere, promoting collaboration among team members and stakeholders.

The platform is designed with scalability in mind, accommodating small businesses with singular HVAC units as well as large enterprises with complex, multi-site systems. This flexibility means that as organizations grow, Bacharach INSIGHT can adapt to their changing needs without requiring extensive modifications.

Furthermore, user customization options allow for tailored dashboards and alerts, ensuring that each team can focus on the most relevant metrics for their operations. This adaptability contributes to improved user experience, enhancing system usability and engagement.

In summary, Bacharach INSIGHT combines intuitive design, powerful analytics, IoT integration, and scalability to redefine HVAC management. By equipping users with actionable insights and fostering proactive maintenance practices, INSIGHT positions organizations to optimize their energy use, reduce costs, and improve overall system reliability. This innovative platform is pioneering a new era for HVAC professionals, facilitating smarter building management with robust, real-time analytics.