Specifications

 

Model 1830

 

Model 1850 & 1850W

 

 

 

 

 

 

 

 

Weight

 

67 lbs..

 

70 lbs..

 

 

 

 

 

 

 

Capacity

70 pints per day @ 160 CFM

 

95 pints per day @ 265 CFM

AHAM DH-1-2008 80°F,

 

 

 

 

 

 

 

60% RH Conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

6..3A operating current

 

8A operating current

115 VAC, Single Phase, 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dehumidifier Inlet

 

Dehumidification: 50°F – 104°F, 40°F dew point minimum

 

Air Conditions

 

Ventilation: 40°F – 140°F, 0%RH – 99%RH (non-condensing)

 

 

 

 

 

 

 

 

Filter

 

 

 

MERV 8, washable

 

 

 

 

 

 

 

 

 

Airflow

External Static

 

 

 

External Static

 

 

 

Pressure ("w.c.)

 

Airflow (CFM)

Pressure ("w.c.)

 

Airflow (CFM)

 

0..0

 

160

 

0..0

 

265

 

 

 

 

 

 

 

 

 

0..2

 

120

 

0..2

 

230

 

 

 

 

 

 

 

 

 

0..4*

 

70

 

0..4

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

0..6*

 

165

 

 

 

 

 

 

 

 

*Maximum design external static pressure.

SET UP DEHUMIDIFIER FOR INSTALLATION

IMPORTANT: Cut the strap securing the compressor shipping support bracket and remove the strap and shipping bracket.. See Figure 1..

Figure 1 – Remove Shipping Bracket

REMOVE SHIPPING BRACKET

CLIP OFF PLASTIC STRAP

90-1908

3

Image 3
Contents Safety Instructions Installation InstructionsTable of Contents Specifications Crawl space, Sealed Attics or basement installations SET UP Dehumidifier for InstallationStandard basement and attic installations fully ducted Closet installationsControl Location To move the controlDetach the on-board control by removing the four Minimum Circuit Capacity Hard WiringMinimum Wire Size AWG VoltageHard Wiring Wiring InstructionsReattach the electrical service panel and side panel Location Considerations Drain Installation Condensate PAN, Condensate Pump and Float SwitchLeveling Ducting Notes Ducting to Hvac System Basement and Attic InstallationsRequired Component DuctworkDuctwork Grilles with 10 Duct Collars Ducting to Hvac System Closet InstallationsOptional Component Optional ComponentsWhole-Home Primary Zone Installation Ducting for TWO Zone InstallationsCrawl SPACE/SEALED Attic Control External ControlWiring to Zone Dampers Wiring the Dehumidifier to the Hvac System and Zone DampersWiring to the Hvac System Optional W & Y WiringSystem SET-UP & Checkout DEH W/AC Zone90-1854selections External Control90-1854energized System SET-UP & CheckoutDehumidification Only Zoning and/or VentilationPress the ON/OFF button to turn the dehumidifier control on Crawl Space or Sealed Attic Remote Control Using ModelSampling will show on the display TWO Zone Primary and SecondaryVentilation Intake Hood AWG WireInstallation & Wiring Ventilation InstallationDehumidifier can ventilate in four modes Outdoor Temperature Sensor InstallationVentilation VENT-AUTO & VENT-TIMEDCFM Delivered Record the required CFMDetermine Fresh AIR Delivery Rate CFM RequiredFor 3 seconds to access Disabled screen appearsRepeatedly until the Vent Ventilation with AN External Control Adjusting Ventilation Time After Initial SET UPSequence of Operation Dehumidifying the Fresh AIRTroubleshooting Diagnostic CodesDiagnostic Codes Troubleshooting Troubleshooting Guide Service Parts 10010759 B2206316A