Aprilaire 1850w, 1830 installation instructions Hard Wiring, Wiring Instructions

Page 7

HARD WIRING (continued)

WIRING INSTRUCTIONS

1.Disconnect electrical service at the main fuse or circuit breaker box..

2.Install any code required electrical disconnects to the line service..

3.Remove the side panel and electrical service panel from the dehumidifier.. See Figure 6..

4.Model 1830 only: Disconnect the power cord connections from the terminals in the electrical service box.. See Figure 7..

5.Model 1830 only: Use pliers to pinch the strain relief and pull it out of the dehumidifier cabinet along with the power cord.. See Figure 6..

6.Route the service cable through the 7/8” diameter hole where the power cord was removed.. USE ONLY COPPER SUPPLY WIRES..

7.Secure the cable/conduit to the dehumidifier using fittings/ connectors approved for the type of cable/conduit used..

8.Connect the ground wire of the service cable to the ground lug in the electrical service box.. See Figure 7..

9.Connect the line voltage wires of the service cable to the LINE BLK and NTRL WHT terminals.. See Figure 7..

10.Reattach the electrical service panel and side panel..

11.Restore electrical service at the main fuse or circuit breaker box..

FIGURE 6 – Electrical Service Box Location

SIDE PANEL

ELECTRICAL

SERVICE BOX

STRAIN

RELIEF

POWER CORD

90-1900

 

FIGURE 7 – Hard Wire to 115 VAC Service

 

ELECTRICAL

 

SERVICE BOX

LINE

 

VOLTAGE

 

NEUTRAL

115V AC WIRING

GROUND

TERMINALS

 

GROUND LUG

 

LINE SERVICE

 

CABLE/CONDUIT

 

FITTING AS

 

REQUIRED

90-1902

 

 

7

Image 7
Contents Safety Instructions Installation InstructionsTable of Contents Specifications Crawl space, Sealed Attics or basement installations SET UP Dehumidifier for InstallationStandard basement and attic installations fully ducted Closet installationsTo move the control Control LocationDetach the on-board control by removing the four Minimum Circuit Capacity Hard WiringMinimum Wire Size AWG VoltageWiring Instructions Hard WiringReattach the electrical service panel and side panel Location Considerations Condensate PAN, Condensate Pump and Float Switch Drain InstallationLeveling Ducting Notes Ducting to Hvac System Basement and Attic InstallationsRequired Component DuctworkDuctwork Grilles with 10 Duct Collars Ducting to Hvac System Closet InstallationsOptional Component Optional ComponentsWhole-Home Primary Zone Installation Ducting for TWO Zone InstallationsCrawl SPACE/SEALED Attic Control External ControlWiring to Zone Dampers Wiring the Dehumidifier to the Hvac System and Zone DampersWiring to the Hvac System Optional W & Y WiringSystem SET-UP & Checkout DEH W/AC Zone90-1854selections External Control90-1854energized System SET-UP & CheckoutDehumidification Only Zoning and/or VentilationPress the ON/OFF button to turn the dehumidifier control on Crawl Space or Sealed Attic Remote Control Using ModelSampling will show on the display TWO Zone Primary and SecondaryVentilation Intake Hood AWG WireInstallation & Wiring Ventilation InstallationDehumidifier can ventilate in four modes Outdoor Temperature Sensor InstallationVentilation VENT-AUTO & VENT-TIMEDCFM Delivered Record the required CFMDetermine Fresh AIR Delivery Rate CFM RequiredDisabled screen appears For 3 seconds to accessRepeatedly until the Vent Ventilation with AN External Control Adjusting Ventilation Time After Initial SET UPSequence of Operation Dehumidifying the Fresh AIRDiagnostic Codes TroubleshootingDiagnostic Codes Troubleshooting Troubleshooting Guide Service Parts 10010759 B2206316A