Aprilaire 1830, 1850w installation instructions Control Location, To move the control

Page 5

SET UP DEHUMIDIFIER FOR INSTALLATION (continued)

CONTROL LOCATION

The on-board control can be located on the top of the dehumidifier or can be relocated to the front of the dehumidifier if the control can not be seen/accessed in the top orientation..

To move the control:

1.Remove the front control panel cover..

2.Remove the filter access door and filter..

3.Detach the on-board control by removing the four

(4) screws around the control.. NOTE: Use one hand to support the bottom of the on-board control when removing..

4.Keep the control in the unit and relocate to the front access hole..

5.Secure the control with the same four screws used to attach the control to the top of the unit..

6.Secure the control panel cover to the top of the unit..

Figure 5 – Control Location

 

 

CONTROL

CONTROL

PANEL COVER

 

 

CONTROL

CONTROL

 

PANEL COVER

 

 

FILTER ACCESS DOOR

 

90-1884

5

Image 5
Contents Safety Instructions Installation InstructionsTable of Contents Specifications Standard basement and attic installations fully ducted SET UP Dehumidifier for InstallationCloset installations Crawl space, Sealed Attics or basement installationsDetach the on-board control by removing the four Control LocationTo move the control Minimum Wire Size AWG Hard WiringVoltage Minimum Circuit CapacityReattach the electrical service panel and side panel Hard WiringWiring Instructions Location Considerations Leveling Drain InstallationCondensate PAN, Condensate Pump and Float Switch Required Component Ducting to Hvac System Basement and Attic InstallationsDuctwork Ducting NotesOptional Component Ducting to Hvac System Closet InstallationsOptional Components Ductwork Grilles with 10 Duct CollarsWhole-Home Primary Zone Installation Ducting for TWO Zone InstallationsCrawl SPACE/SEALED Attic Control External ControlWiring to the Hvac System Wiring the Dehumidifier to the Hvac System and Zone DampersOptional W & Y Wiring Wiring to Zone DampersSystem SET-UP & Checkout 90-1854selections ZoneExternal Control DEH W/ACDehumidification Only System SET-UP & CheckoutZoning and/or Ventilation 90-1854energizedSampling will show on the display Crawl Space or Sealed Attic Remote Control Using ModelTWO Zone Primary and Secondary Press the ON/OFF button to turn the dehumidifier control onInstallation & Wiring Intake Hood AWG WireVentilation Installation VentilationVentilation Outdoor Temperature Sensor InstallationVENT-AUTO & VENT-TIMED Dehumidifier can ventilate in four modesDetermine Fresh AIR Delivery Rate Record the required CFMCFM Required CFM DeliveredRepeatedly until the Vent For 3 seconds to accessDisabled screen appears Sequence of Operation Adjusting Ventilation Time After Initial SET UPDehumidifying the Fresh AIR Ventilation with AN External ControlDiagnostic Codes TroubleshootingDiagnostic Codes Troubleshooting Troubleshooting Guide Service Parts 10010759 B2206316A