Mamiya C24, C32, C28 manual Refer back to page 52 of fault finding to continue

Page 56

FINDING

FAULT FINDING

Continued from page 55

of fault finding

FAULT

Is the burner light on?

yes

Does the burner remain alight more than 10 seconds?

yes

Is the burner pressure within min and max value* with the boiler running?

yes

no

no

no

Can the minimum burner pressure be achieved ?

(Pressure values are given

in Table 2 on page 4)

yes

Is the condense freely discharged through the condensate trap and pipework?

yes

Replace faulty PCB

Is the position of the detection electrode correct, and electrode undamaged? Refer to frame 49.

yes

Is the resistance of the

detection electrode

assembly < 5Ω from tip to

connector ?

yes

Is the polarity of

the mains correct?

yes

Replace faulty PCB

Adjust burner pressure.

Refer to frame 35.

no

no

no

no

no

Adjust the burner minimum pressure refer to frame 35

Check the condensate trap and discharge pipework for cleanliness

Rectify electrode position or replace faulty electrode.

Is the lead connected ?

yes

Replace faulty detection

lead assy.

Rectify wiring fault

no

Connect lead correctly

Refer back to page 52 of fault finding to continue.

* see Table 2 at page 4 for the correct value

56

mini HE --- Installation & Servicing

Image 56
Contents Installation and servicing Mini HE --- Installation & Servicing Document Amendments General Boiler DataPerformance Data --- Central Heating Domestic Hot WaterContents Benchmark Commissioning Checklist DetailsGeneral Boiler Water Connection Boiler ClearancesGAS Safety IntroductionOptional Extra Kits Safe HandlingFlue Installation Requirements GAS SupplySafe Handling of Substances Location of Boiler and Flue OutletWater Circulation System Water TreatmentAIR Supply Additional PumpsElectrical Supply RequirementsHydraulic Loss Remaining pump capacity Mini HE C24, mini HE C28Size of expansion vessel General Boiler Control Interlocks Domestic HOT Water RequirementsGeneral Boiler Water Circuit Diagram Installation Installation Boiler AssemblyInstallation Unpacking Pack a contentsHardware pack contents Pack B contentsInstallation Fitting the Flue SystemRear Flue Assembly Refer to the following diagram for the model mini HE C32Twin Pipe Flue DuctWall Mounting Template rear flue Fitting the Extension Kits Installation Cutting the FlueRing Installation Fitting the Optional Roof Flue Roof Flue KIT CONTENTS/OPTIONSInstallation Flue Terminal Position Flue ArrangementAssembling the Roof Flue KIT Flue over 3 meters longInstallation Fitting the Wall Mounting Plate Fit the service valves, washers and tail pipes as shownMounting the Boiler ConnectionsSafety Valve Drain Condensate DrainLocate the gasket and flue turret on the top of the boiler Flues over 1 meter longElectrical Connections For external controls wiring see frameIncoming mains wiring detail Pictorial Wiring Installation Functional Flow Diagram Control pcbExternal Electrical Controls Electrical Connections for a Combi BoilerInstallation Initial Lighting Minimum valve setting To Adjust PressuresMaximum valve setting Anti Cycling Setting Commissioning and TestingElectrical Installation Gas InstallationGeneral Checks Installation GAS Conversion Handing OverServicing Servicing ScheduleServicing Removal of Outer and Inner Casing Servicing Burner Removal and Cleaning Cleaning the Heat ExchangerRE---ASSEMBLY Burner Pressure CheckServicing FAN and Venturi Removal and Cleaning Remove the fan by sliding it towards left see the arrowSpark and Detection Electrode Replacement Burner ReplacementBurner Injectors Replacement When replacing any componentServicing Overheat Thermostat Replacement Flue Temperature Probe ReplacementTemperature Probe Replacement Removal of CH temperature probeGAS Valve Replacement Expansion Vessel ReplacementAIR Pressure Switch Replacement Servicing FAN ReplacementVenturi Replacement Pump Replacement Complete Servicing Electronic CONTROL/IGNITION PCB Replacement Boiler mode setting Servicing CH Flow Switch Replacement CH Flow Switch Membrane ReplacementFlow limiter Servicing DHW Flow Switch ReplacementDHW Filter and Flow Limiter Replacement Servicing Primary Heat Exchanger Replacement Recuperator ReplacementServicing Diverter Valve Actuator Replacement Diverter Valve Internal Parts ReplacementServicing DHW Heat Exchanger Replacement CH Drain Cock ReplacementTo replace the condensate trap Condensate Trap ReplacementTo clean the condensate trap and drain Normal operation OFFFault Finding FindingFrom Fault finding Fault Finding Fault Refer back to page 52 of fault finding to continue Fault Finding From Burner mod. mini HE C28, mini HE C32 075535Fan mod. mini HE C28, mini HE C32 17398422 23 Installer Notification Guidelines GAS Boiler Commissioning Checklist Service Interval Record Technical Training Ideal boilersCorrectly Ignition at attempt Installer the contact fire not doesInstaller Water hot or GAS of Escape MaintenanceCleaning Clearances Minimum Lights DiagnosticBoiler the Light to

C28, C24, C32 specifications

The Mamiya C series is celebrated among photography enthusiasts for its unique twin-lens reflex (TLR) design, offering both a classic aesthetic and innovative features that set it apart in the world of medium format cameras. The C32, C24, and C28 models represent a range of technology and design advancements that cater to various shooting needs.

The Mamiya C32, introduced in the early 1970s, is renowned for its precision engineering and versatility. This model features interchangeable lenses, allowing photographers to switch between different focal lengths for creative flexibility. The camera supports 120 and 220 film formats, enabling higher film capacities for extended shooting sessions. An essential feature of the C32 is its built-in light meter, which enhances exposure accuracy by providing real-time readings. The camera's bright waist-level finder offers excellent viewing comfort and composition aid, attracting those who appreciate a more hands-on shooting experience.

Next in line, the Mamiya C24 offers a slightly more compact and lighter design, making it an appealing option for documentary and street photographers. While still featuring the electronic leaf shutter system utilized in the C32, the C24 omits built-in metering, which encourages users to develop their exposure skills. The lens selection remains robust, with options ranging from wide-angle to telephoto, allowing for creative versatility. The C24's rugged build quality and reliable shutter performance make it a trusted companion in various shooting conditions.

Lastly, the Mamiya C28 provides a perfect blend of portability and advanced capabilities. With its ergonomic design and improved lens coatings, the C28 offers enhanced image quality with better contrast and sharpness. Similar to its predecessors, it utilizes an interchangeable lens system but enhances user convenience through quick-to-use shutter speeds and aperture settings. The camera is also compatible with a range of accessories, such as flash units and close-up attachments, further expanding its creative potential.

In summary, the Mamiya C32, C24, and C28 each present unique features and technological advancements that cater to various types of photographers. Whether it's the precision of the C32, the compact convenience of the C24, or the versatile performance of the C28, these cameras maintain a special place in the hearts of medium format enthusiasts, showcasing the blend of craftsmanship and innovation that Mamiya is known for.