Mamiya C24 manual Burner mod. mini HE C28, mini HE C32, 075535, Fan mod. mini HE C28, mini HE C32

Page 59

The following are parts commonly required as replacements, due to damage or expendability. The failure or absence is likely to affect the safety and/or performance of this appliance.

The list is extracted from the British Gas List of Parts which contains all available spare parts.

The full list is held by British Gas, Caradon Plumbing Ltd. distributors and merchants.

When ordering spares please quote:

1Boiler model (see Data Plate)

2Appliance G.C. number (see Data Plate)

3 Description

4 Quantity

5 Product No.

Key

G.C. No

Description

No. Off/

Product No.

No.

 

 

Boiler

 

 

 

 

 

 

1

173---148

Burner (mod. mini HE C24)

1

075427

 

 

 

 

 

 

173---149

Burner (mod. mini HE C28, mini HE C32)

1

075535

 

 

 

 

 

2

H07---337

Main heat exchanger + ’O’ rings (mod. mini HE C24)

1

173991

 

 

 

 

 

 

H07---542

Main heat exchanger + ’O’ rings (mod. mini HE C28)

1

173992

 

 

 

 

 

 

H45---153

Main heat exchanger + ’O’ rings (mod. mini HE C32)

1

174481

 

 

 

 

 

3

H07---112

Recuperator

1

173993

 

 

 

 

 

4

169---069

Injectors for natural gas (mod. mini HE C24)

12

075692

 

 

 

 

 

 

 

Injectors for natural gas (mod. mini HE C28, mini HE C32)

14

 

 

 

 

 

 

 

E01---156

Injectors for LPG (mod. mini HE C24)

12

173982

 

 

 

 

 

 

 

Injectors for LPG (mod. mini HE C28)

14

 

 

 

 

 

 

 

H45---178

Injectors for LPG (mod. mini HE C32)

14

174483

 

 

 

 

 

5

H21---048

Fan (mod. mini HE C24)

1

173983

 

 

 

 

 

 

H21---049

Fan (mod. mini HE C28, mini HE C32)

1

173984

 

 

 

 

 

6

H44---162

Gas valve + gaskets

1

174465

 

 

 

 

 

7

169---127

Air pressure switch (mod. mini HE C24, mini HE C32)

1

173236

 

 

 

 

 

 

H08---605

Air pressure switch (mod. mini HE C28)

1

173136

 

 

 

 

 

8

E83---013

Safety valve

1

172494

 

 

 

 

 

9

H44---169

Electronic regulation p.c.b.

1

174469

 

 

 

 

 

10

E00---684

Primary circuit flow switch

1

075419

 

 

 

 

 

11

E83---082

DHW flow switch

1

174462

 

 

 

 

 

12

E00---688

Main. flow switch membrane

1

075421

 

 

 

 

 

13

E83---101

Overheat thermostat

1

172512

 

 

 

 

 

14

E57---048

DHW heat exchanger + ’O’ rings (mod. mini HE C24)

1

075460

 

 

 

 

 

 

E57---049

DHW heat exchanger + ’O’ rings (mod. mini HE C28, mini HE C32)

1

075540

 

 

 

 

 

15

H20---986

Automatic air purger valve

1

173813

 

 

 

 

 

16

H07---840

Pump + ’O’ rings

1

174004

 

 

 

 

 

17

E83---145

Temperature---pressure gauge

1

172551

 

 

 

 

 

18

H32---598

Flue temperature probe

1

174478

 

 

 

 

 

19

E83---086

Three way diverter valve (electric actuator)

1

172505

 

 

 

 

 

20

H21---060

Sealed chamber gaskets kit

1

173986

 

 

 

 

 

21

H32---550

Magnetic flow switch and filter

1

174461

 

 

 

 

 

22

E83---127

Ignition electrode --- left

1

172533

 

 

 

 

 

23

E83---126

Ignition electrode --- right

1

172532

 

 

 

 

 

24

E83---122

Detection electrode

1

172531

 

 

 

 

 

25

E69---243

Window (glass + rubber frame)

1

170977

 

 

 

 

 

26

169---141

1/2” flat gasket

3

075514

 

 

 

 

 

27

169---033

3/4” flat gasket

4

075415

 

 

 

 

 

28

H44---170

Fuse 3,15 AF

2

174470

 

 

 

 

 

29

164---026

Temperature probe (main or DHW circuit)

1

172496

 

 

 

 

 

30

H21---052

Side case panel

2

173987

 

 

 

 

 

mini HE --- Installation & Servicing

59

Image 59
Contents Installation and servicing Mini HE --- Installation & Servicing Document Amendments Domestic Hot Water GeneralBoiler Data Performance Data --- Central HeatingBenchmark Commissioning Checklist Details ContentsBoiler Clearances General Boiler Water ConnectionSafe Handling GAS SafetyIntroduction Optional Extra KitsLocation of Boiler and Flue Outlet Flue Installation RequirementsGAS Supply Safe Handling of SubstancesAdditional Pumps Water Circulation SystemWater Treatment AIR SupplyRequirements Electrical SupplyHydraulic Loss Remaining pump capacity Mini HE C24, mini HE C28Size of expansion vessel Domestic HOT Water Requirements General Boiler Control InterlocksGeneral Boiler Water Circuit Diagram Installation Boiler Assembly InstallationPack B contents Installation UnpackingPack a contents Hardware pack contentsFitting the Flue System InstallationFlue Duct Rear Flue AssemblyRefer to the following diagram for the model mini HE C32 Twin PipeWall Mounting Template rear flue Fitting the Extension Kits Installation Cutting the FlueRing Roof Flue KIT CONTENTS/OPTIONS Installation Fitting the Optional Roof FlueFlue Arrangement Installation Flue Terminal PositionFlue over 3 meters long Assembling the Roof Flue KITConnections Installation Fitting the Wall Mounting PlateFit the service valves, washers and tail pipes as shown Mounting the BoilerFlues over 1 meter long Safety Valve DrainCondensate Drain Locate the gasket and flue turret on the top of the boilerElectrical Connections For external controls wiring see frameIncoming mains wiring detail Pictorial Wiring Control pcb Installation Functional Flow DiagramElectrical Connections for a Combi Boiler External Electrical ControlsInstallation Initial Lighting Minimum valve setting To Adjust PressuresMaximum valve setting Gas Installation Anti Cycling SettingCommissioning and Testing Electrical InstallationGeneral Checks Handing Over Installation GAS ConversionServicing Schedule ServicingServicing Removal of Outer and Inner Casing Burner Pressure Check Servicing Burner Removal and CleaningCleaning the Heat Exchanger RE---ASSEMBLYRemove the fan by sliding it towards left see the arrow Servicing FAN and Venturi Removal and CleaningWhen replacing any component Spark and Detection Electrode ReplacementBurner Replacement Burner Injectors ReplacementRemoval of CH temperature probe Servicing Overheat Thermostat ReplacementFlue Temperature Probe Replacement Temperature Probe ReplacementExpansion Vessel Replacement GAS Valve ReplacementAIR Pressure Switch Replacement Servicing FAN ReplacementVenturi Replacement Pump Replacement Complete Servicing Electronic CONTROL/IGNITION PCB Replacement Boiler mode setting CH Flow Switch Membrane Replacement Servicing CH Flow Switch ReplacementFlow limiter Servicing DHW Flow Switch ReplacementDHW Filter and Flow Limiter Replacement Recuperator Replacement Servicing Primary Heat Exchanger ReplacementDiverter Valve Internal Parts Replacement Servicing Diverter Valve Actuator ReplacementCH Drain Cock Replacement Servicing DHW Heat Exchanger ReplacementTo replace the condensate trap Condensate Trap ReplacementTo clean the condensate trap and drain OFF Normal operationFinding Fault FindingFrom Fault finding Fault Finding Fault Refer back to page 52 of fault finding to continue Fault Finding From 173984 Burner mod. mini HE C28, mini HE C32075535 Fan mod. mini HE C28, mini HE C3222 23 Installer Notification Guidelines GAS Boiler Commissioning Checklist Service Interval Record Ideal boilers Technical TrainingCorrectly Ignition at attempt Installer the contact fire not doesInstaller Water hot or GAS of Escape MaintenanceCleaning Clearances Minimum Lights DiagnosticBoiler the Light to

C28, C24, C32 specifications

The Mamiya C series is celebrated among photography enthusiasts for its unique twin-lens reflex (TLR) design, offering both a classic aesthetic and innovative features that set it apart in the world of medium format cameras. The C32, C24, and C28 models represent a range of technology and design advancements that cater to various shooting needs.

The Mamiya C32, introduced in the early 1970s, is renowned for its precision engineering and versatility. This model features interchangeable lenses, allowing photographers to switch between different focal lengths for creative flexibility. The camera supports 120 and 220 film formats, enabling higher film capacities for extended shooting sessions. An essential feature of the C32 is its built-in light meter, which enhances exposure accuracy by providing real-time readings. The camera's bright waist-level finder offers excellent viewing comfort and composition aid, attracting those who appreciate a more hands-on shooting experience.

Next in line, the Mamiya C24 offers a slightly more compact and lighter design, making it an appealing option for documentary and street photographers. While still featuring the electronic leaf shutter system utilized in the C32, the C24 omits built-in metering, which encourages users to develop their exposure skills. The lens selection remains robust, with options ranging from wide-angle to telephoto, allowing for creative versatility. The C24's rugged build quality and reliable shutter performance make it a trusted companion in various shooting conditions.

Lastly, the Mamiya C28 provides a perfect blend of portability and advanced capabilities. With its ergonomic design and improved lens coatings, the C28 offers enhanced image quality with better contrast and sharpness. Similar to its predecessors, it utilizes an interchangeable lens system but enhances user convenience through quick-to-use shutter speeds and aperture settings. The camera is also compatible with a range of accessories, such as flash units and close-up attachments, further expanding its creative potential.

In summary, the Mamiya C32, C24, and C28 each present unique features and technological advancements that cater to various types of photographers. Whether it's the precision of the C32, the compact convenience of the C24, or the versatile performance of the C28, these cameras maintain a special place in the hearts of medium format enthusiasts, showcasing the blend of craftsmanship and innovation that Mamiya is known for.