Lochinvar 399 - 800 service manual Parameter table, Temperature Data

Page 15

Service Manual

1Service (continued)

Parameter table

Table 1D This table lists SMART SYSTEM control module parameters and where to access them

GENERAL

MENU

SUB ITEM

DESCRIPTION

SEE

USER ACCESS

INSTALLER ACCESS

PAGE

DISPLAY

MODIFY

DISPLAY

MODIFY

 

 

 

 

 

 

 

 

 

 

 

 

1

Boiler Model

17

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

2

User Code

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

3

Date and Time

17

Yes

Yes

Yes

Yes

A

 

 

 

 

 

 

 

4

Software Version

17

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

5

Temperature Units

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

6

Night Setback Temperature

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

7

Night Setback Times

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

TEMPERATURE

DATA

 

 

 

1

SH Set Point User

17

Yes

Yes

Yes

Yes

SETTING

 

 

 

 

 

 

 

 

 

 

 

2

SH Minimum Set Point

17

No

No

Yes

Yes

 

B

 

 

 

 

 

 

 

3

SH Maximum Set Point

17

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

SH Offset

17

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

5

SH Differential

18

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOGGING

 

 

1

Hours Running SH

18

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

 

2

Hours Running DHW

18

Yes

No

Yes

No

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

3

Ignition Attempts

18

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Show Last 10 Errors

18

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

 

FUNCTIONS

D

1

Reset Last 10 Errors

18

No

No

Yes

Yes

 

 

 

 

 

 

 

2

Service Mode Delay

18

No

No

Yes

Yes

 

 

 

 

 

 

 

DHW SETTINGS

 

 

1

DHW Boiler Set Point

18

Yes

Yes

Yes

Yes

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

2

SH/DHW Switching Time

18

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

3

DHW Tank Set Point

18

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR RESETAIR

 

1

Minimum Air Temperature

18

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

2

Maximum Air Temperature

19

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

3

Maximum SH Set Point

19

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

4

Minimum SH Set Point

19

No

No

Yes

Yes

F

 

 

 

 

 

 

 

5

Outdoor Air Shutdown

19

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

6

Outdoor Air Shutdown

19

Yes

Yes

Yes

Yes

 

Differential

 

 

 

 

 

 

 

 

7

Shift Air Reset

19

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

8

Boost Temperature

20

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

9

Boost Time

20

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

15

Image 15 Contents
Models 399 Contents Please read before proceeding Handling ceramic fiber materialsNiosh stated First Aid When servicing boiler Troubleshooting What is in this manual?Service MaintenanceNear boiler piping ServiceMenu / Exit UP Down Knight XL displayControl inputs Control outputs Smart Control ModuleSequence of operation General OperationHow the boiler operates How the control module operates BLR Ignition Sequence of operationBLR SH 41% Rate Use this procedure to access menus from the display panel Display panel menu accessValue will appear Display panel parameter accessParameter table Temperature DataControl Circulation Service Viewable and changeable control parameters Temperature settingsFunctions DHW settingsOutdoor air reset Data loggingMinimum SH set point Maximum air temperatureShift reset curve Maximum SH set pointAnti-cycling Boiler cascade address Control modesSH controlling sensor SH sourceService Notification Cascade offsetCirculation pumps Maintenance Maintenance and annual startup Service technicianOwner maintenance Maintenance Check boiler relief valve Flue vent system and air pipingCheck water system Check expansion tankInspect ignition and flame sense electrodes Check ignition ground wiringCheck all boiler wiring Check control settingsCheck flame signal Cleaning boiler heat exchangerReview with owner Check the following TroubleshootingBefore troubleshooting Check control module fusesUnit Does Not No DisplayNo Burner OperationTemperature Resistance Checking temperature sensorsSystem Pump NoisyNo Pump Operation Boiler PumpSequence Switch/LWCOFlow FlameNo Flame Ign Anti-cyclingRunning No FlameFan Speed Low Adjustable HighLimit w/Manual Fan LowSensor Shorted Fan HighFan Speed High Sensor OpenTemp O/Shoot Open Rem Ctrl FltParameters ProgrLow 24 VAC Service BlkWatch Dog Error No Error StoredGas Supply Pressure Combustion Analysis ProcedureGas Valve Adjustment Or ObstructionGas valve adjustment procedure ModelModels 600 Page Page KBX-SER Rev E