Near boiler piping

This piping reference is included to specify the Near Boiler Piping specific to the Knight XL. This piping scheme is important for proper operation of the SMART SYSTEM control. See the Knight XL Installation and Operation Manual for more detailed piping diagrams.

FROM

SYSTEM

DOMESTIC HOT

WATER PUMP

SYSTEM PUMP

FROM

TO

SYSTEM

TO

INDIRECT

DOMESTIC HOT WATER TANK

BOILER PUMP

TO FLOOR

DRAIN

6

Image 6 Contents
Models 399 Contents Please read before proceeding Handling ceramic fiber materialsNiosh stated First Aid When servicing boiler Maintenance What is in this manual?Service TroubleshootingService Near boiler pipingKnight XL display Menu / Exit UP DownControl inputs Smart Control Module Control outputsHow the control module operates General OperationHow the boiler operates Sequence of operationSequence of operation BLR IgnitionBLR SH 41% Rate Display panel menu access Use this procedure to access menus from the display panelDisplay panel parameter access Value will appearTemperature Data Parameter tableControl Circulation Service Temperature settings Viewable and changeable control parametersData logging DHW settingsOutdoor air reset FunctionsMaximum SH set point Maximum air temperatureShift reset curve Minimum SH set pointAnti-cycling SH source Control modesSH controlling sensor Boiler cascade addressService Notification Cascade offsetCirculation pumps Maintenance Maintenance and annual startup Service technicianOwner maintenance Maintenance Check expansion tank Flue vent system and air pipingCheck water system Check boiler relief valveCheck control settings Check ignition ground wiringCheck all boiler wiring Inspect ignition and flame sense electrodesCheck flame signal Cleaning boiler heat exchangerReview with owner Check control module fuses TroubleshootingBefore troubleshooting Check the followingOperation No DisplayNo Burner Unit Does NotChecking temperature sensors Temperature ResistanceOperation Boiler Pump NoisyNo Pump System PumpFlame Switch/LWCOFlow SequenceAnti-cycling No Flame IgnNo Flame RunningFan Low Adjustable HighLimit w/Manual Fan Speed LowSensor Open Fan HighFan Speed High Sensor ShortedTemp O/Shoot Progr Rem Ctrl FltParameters OpenNo Error Stored Service BlkWatch Dog Error Low 24 VACOr Obstruction Combustion Analysis ProcedureGas Valve Adjustment Gas Supply PressureGas valve adjustment procedure ModelModels 600 Page Page KBX-SER Rev E
Related manuals
Manual 20 pages 31.65 Kb