Lochinvar 399 - 800 Service Blk, Low 24 VAC, Watch Dog Error, Write EEProm, CRC Parameters

Page 39

Service Manual

3Troubleshooting (continued)

Table 3F (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT

DESCRIPTION

CORRECTIVE ACTION

 

 

 

 

While the unit is in Service Mode, the outlet

• Establish a heating load to remove the heat from the

 

temperature has exceeded 185°F.

boiler loop.

 

 

 

 

 

 

• Verify that the system is full of water and that all air

 

 

has been properly purged from the system.

 

 

• Verify that the boiler is piped properly into the heating

 

 

system. Refer to Section 6 - Hydronic Piping of the

 

 

Knight XL Installation and Operation Manual for the

 

 

proper piping methods for the Knight

XL boiler.

Service Blk

 

• Check voltage to the boiler pump motor on a call for

 

 

 

 

heat. If voltage is not present, check the wiring back

 

 

to the pump relay. Replace the pump relay if

 

 

necessary.

 

 

 

 

 

 

• If 120 VAC is present on a call for heat and the boiler

 

 

pump is not operating, replace the pump.

 

 

• Verify that the boiler pump is set to the proper speed

 

 

or that the boiler pump is the proper size. Reference

 

 

Section 6 - Hydronic Piping

of the Knight

 

 

XL Installation and Operation Manual for boiler

 

 

pump specifications.

 

 

 

 

 

 

 

 

120 VAC input to the main control board has

• Check 120 VAC supply to the transformer.

 

dropped below 80 VAC.

 

 

 

 

 

Low 24 VAC

 

• Check wiring connections at the low voltage terminal

 

strip.

 

 

 

 

 

 

• Check the wire size/length to remote devices.

 

 

• Replace the transformer.

 

 

 

 

Watch Dog Error

The main control board has detected an

• Replace the main control board.

 

 

 

 

internal fault.

 

 

 

 

 

 

 

 

 

 

 

 

Write EEProm

The main control board has detected an

• Replace the main control board.

 

 

 

 

internal fault.

 

 

 

 

 

 

 

 

 

 

 

 

 

The main control board has detected an

• Replace the main control board.

 

 

 

 

CRC Parameters

internal fault.

 

 

 

 

 

 

 

 

 

The main control board has detected an

• Press the ENTER/RESET button on the SMART

No Error Stored

internal fault.

SYSTEM display panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

39

 

 

 

 

 

 

 

 

 

 

 

Image 39 Contents
Models 399 Contents Please read before proceeding Handling ceramic fiber materialsNiosh stated First Aid When servicing boiler Troubleshooting What is in this manual?Service MaintenanceNear boiler piping ServiceMenu / Exit UP Down Knight XL displayControl inputs Control outputs Smart Control ModuleSequence of operation General OperationHow the boiler operates How the control module operatesBLR Ignition Sequence of operationBLR SH 41% Rate Use this procedure to access menus from the display panel Display panel menu accessValue will appear Display panel parameter accessParameter table Temperature DataControl Circulation Service Viewable and changeable control parameters Temperature settingsFunctions DHW settingsOutdoor air reset Data loggingMinimum SH set point Maximum air temperatureShift reset curve Maximum SH set pointAnti-cycling Boiler cascade address Control modesSH controlling sensor SH sourceService Notification Cascade offsetCirculation pumps Maintenance Maintenance and annual startup Service technicianOwner maintenance Maintenance Check boiler relief valve Flue vent system and air pipingCheck water system Check expansion tankInspect ignition and flame sense electrodes Check ignition ground wiringCheck all boiler wiring Check control settingsCheck flame signal Cleaning boiler heat exchangerReview with owner Check the following TroubleshootingBefore troubleshooting Check control module fusesUnit Does Not No DisplayNo Burner OperationTemperature Resistance Checking temperature sensorsSystem Pump NoisyNo Pump Operation Boiler PumpSequence Switch/LWCOFlow FlameNo Flame Ign Anti-cyclingRunning No Flame Fan Speed Low Adjustable High Limit w/Manual Fan LowSensor Shorted Fan HighFan Speed High Sensor OpenTemp O/Shoot Open Rem Ctrl FltParameters ProgrLow 24 VAC Service BlkWatch Dog Error No Error StoredGas Supply Pressure Combustion Analysis ProcedureGas Valve Adjustment Or ObstructionGas valve adjustment procedure ModelModels 600 Page Page KBX-SER Rev E