Key

Description

 

 

[Quantity] Part Number

 

 

 

 

 

 

 

 

 

 

No.

PVG-3

PVG-4

PVG-5

 

PVG-6

PVG-7

PVG-8

PVG-9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. BURNER ASSEMBLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve (Natural Gas),

 

81660282

 

 

 

N/A

 

 

Honeywell VR8204P1171

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve (Natural Gas),

 

N/A

 

 

 

81660283

 

 

Honeywell VR8304P4496

 

 

 

 

 

5A

 

 

 

 

 

 

 

 

Gas Valve (LP Gas),

 

81660146

 

 

 

N/A

 

 

 

 

 

 

 

 

Honeywell VR8204C3015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve (LP Gas),

 

N/A

 

 

 

81660181

 

 

Honeywell VR8304P4280

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5B

Nipple, ½” NPT x Close

 

806600040

 

 

 

N/A

 

 

 

 

 

 

 

 

 

 

Nipple, ¾” NPT x Close

 

N/A

 

 

 

806600022

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5C

Union, ½” NPT

 

806604023

 

 

 

N/A

 

 

 

 

 

 

 

 

 

 

Union, ¾” NPT

 

N/A

 

 

 

806604001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5D

½” Gas Manifold

82207031

82207041

82207051

 

82207061

---

---

---

 

 

 

 

 

 

 

 

 

¾” Gas Manifold

---

---

---

 

---

82207071

82207081

82207091

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner Orifices - Natural Gas #47

[4]

[6]

[8]

 

[10]

[12]

[14]

[16]

 

822710

822710

822710

 

822710

822710

822710

822710

5E

 

 

Burner Orifices - LP Gas 1.20 mm

[4]

[6]

[8]

 

[10]

[12]

[14]

[16]

 

 

 

822792

822792

822792

 

822792

822792

822792

822792

 

 

 

5F

Pilot Assembly - Natural Gas

 

 

 

8236163

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Assembly - LP Gas

 

 

 

8236164

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5G

Pilot Burner

 

 

 

100147-01

 

 

 

 

 

 

 

 

 

 

 

 

 

5H

Main Burner

[3]

[5]

[7]

 

[9]

[11]

[13]

[15]

100146-01

100146-01

100146-01

 

100146-01

100146-01

100146-01

100146-01

 

 

 

5J

Pilot Tubing

 

 

 

8236122

 

 

 

 

 

 

 

 

 

 

 

 

5K

Self Tapping Screw, ¼ - 20 x ½”

 

 

 

[6] 80860700

 

 

 

 

 

 

 

 

 

 

 

 

 

59

Image 59
Contents 8140708R8-8/08 Price $5.00 PVGImportant Information Read Carefully Page Table of Contents Dimensions Pre-Installation Do not drop boiler. Do not bump boiler jacket against floor II. Unpack BoilerVent System Components Included with Boiler III. VentingVent Length Burnham Vent System ComponentsGeneral Guidelines Vent Guidelines Due to Removal of an Existing BoilerBurnham Gasketed Vent Joint Detail Install Vent Pipe, Burnham Gasketed Vent SystemHorizontal Venting System. See Figures 4, 4A Vent PipingRecommended Horizontal Vent Installation Alternate Horizontal Vent Installation Horizontal Vent Terminal Configuration 3 or 4 Vent Vertical Venting System See Figures 6, 7 Vertical Vent Installation Page Exterior run to be included in equivalent vent lengths Install vent pipingLwco Location IV. Water Piping and TrimHow to Test How to WireSupply Water Manifold Piping Page Page Gas Ratings Gas PipingFailure to properly pipe gas supply to boiler may Valves Fully Open Page VI. Electrical Internal Boiler Wiring Schematic Diagram Internal Boiler Wiring Ladder Diagram System Controls and Wiring Single Heating Zone Only Wiring Schematic Page Circulator Zoned System Wiring Schematic Zone Valve Zoned System Wiring Schematic Page Modular Boiler Water Manifold Sizing VII. Modular InstallationModule Sizing Do not manifold vent pipes togetherModular Boiler Piping VIII. System Start-up Operating Instructions Ignition Module Terminal Cross-Reference Operating InstructionsGreen LED Status Codes Honeywell Electronic Ignition Troubleshooting Guide Check limit Sequence of OperationGas Flow Rate in Cubic Feet Per Hour Adjust gas input rate to boilerLow water cutoff if so equipped IX. ServiceMain Burners and Firebox Procedure for measuring differential pressure See FigureFlue and Burner Cleanout, 1 Burner Pilot Burner Location Differential Pressure Switch SettingsPage Page XI. Repair Parts Casting Assembly Page Base Assembly Sheet Metal Screw, #8 x 1/2 FAN/CANOPY Assembly Page Burner Assembly Control Panel Assembly Jacket Parts Miscellaneous Parts Carton Avoid Breathing Fiber Particulates and Dust Limited Warranty

PVG specifications

Burnham PVG, an innovative leader in the heating industry, presents a range of high-efficiency gas boilers that are designed specifically for residential applications. Burnham has established a solid reputation for producing reliable and durable heating solutions, with the PVG series exemplifying their commitment to quality and performance.

One of the standout features of the Burnham PVG is its advanced stainless steel heat exchanger. This design not only ensures superior heat transfer but also enhances durability and resistance to corrosion compared to traditional cast iron counterparts. The use of stainless steel contributes to the longevity of the system, allowing homeowners to enjoy efficient heating for years with less risk of breakdown.

The PVG series incorporates cutting-edge modulating technology, which adjusts the boiler’s output to match the heating demand. This modulating feature allows for more precise temperature control, optimizing energy consumption and minimizing fuel costs. Unlike conventional boilers that operate at a fixed output, the ability to modulate enables the PVG to deliver precisely the right amount of energy when needed, thus enhancing overall system efficiency.

In addition to its efficiency and performance capabilities, the Burnham PVG is designed with ease of installation and maintenance in mind. The compact design enables versatile installation options, even in tight spaces or retrofit applications. Furthermore, the accessible panel layout simplifies service and maintenance tasks, allowing HVAC professionals to perform routine checks and repairs with ease.

The PVG series also emphasizes user-friendly operations, featuring intuitive controls that allow for straightforward adjustments and monitoring. With options for direct vent and conventional venting systems, homeowners can select the best installation method for their specific needs and living environment.

Additionally, the Burnham PVG aligns with environmental considerations by meeting stringent emissions standards, contributing to reduced greenhouse gas outputs. With its energy-efficient operation and commitment to sustainability, the PVG series represents a forward-thinking choice for those looking to reduce their carbon footprint while enhancing home comfort.

In summary, Burnham PVG is characterized by its durable stainless steel construction, modulating technology, compact design, user-friendly controls, and eco-conscious performance. This series exemplifies what modern residential heating solutions should aspire to achieve: efficiency, reliability, and sustainability, making it an excellent choice for intelligent energy management in the home.