Burnham PVG manual Jacket Parts

Page 61

Key

Description

 

 

[Quantity] Part Number

 

 

 

 

 

 

 

 

 

No.

PVG-3

PVG-4

PVG-5

PVG-6

PVG-7

PVG-8

PVG-9

 

 

 

 

 

 

 

 

 

 

 

 

7. JACKET PARTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7A

Left Side Panel

 

 

 

60407002

 

 

 

 

 

 

 

 

 

 

 

 

7B

Right Side Panel

 

 

 

60407001

 

 

 

 

 

 

 

 

 

 

 

 

7C

Rear Panel

60407033

60407043

60407053

60407063

60407073

60407083

60407093

 

 

 

 

 

 

 

 

 

7D

Vestibule Panel

60407034

60407044

60407054

60407064

60407074

60407084

60407094

 

 

 

 

 

 

 

 

 

7E

Top Panel

60407032

60407042

60407052

60407062

60407072

60407082

60407092

 

 

 

 

 

 

 

 

 

7F

Front Door

101354-03

101354-04

101354-05

101354-06

101354-07

101354-08

101354-09

 

 

 

 

 

 

 

 

 

7G

Jacket Cover Plate

 

 

 

80407001

 

 

 

 

 

 

 

 

 

 

 

 

7H

Handle

 

 

 

8056184

 

 

 

 

 

 

 

 

 

 

 

 

7J

Door Clip

 

 

 

[2] 7041921

 

 

 

 

 

 

 

 

 

 

 

 

7K

Bushing

 

 

 

8136048

 

 

 

 

 

 

 

 

 

 

 

 

7L

Burnham Logo

 

 

 

81460099

 

 

 

 

 

 

 

 

 

 

 

 

61

Image 61
Contents 8140708R8-8/08 Price $5.00 PVGImportant Information Read Carefully Page Table of Contents Dimensions Pre-Installation Do not drop boiler. Do not bump boiler jacket against floor II. Unpack BoilerVent System Components Included with Boiler III. VentingVent Length Burnham Vent System ComponentsGeneral Guidelines Vent Guidelines Due to Removal of an Existing BoilerBurnham Gasketed Vent Joint Detail Install Vent Pipe, Burnham Gasketed Vent SystemHorizontal Venting System. See Figures 4, 4A Vent PipingRecommended Horizontal Vent Installation Alternate Horizontal Vent Installation Horizontal Vent Terminal Configuration 3 or 4 Vent Vertical Venting System See Figures 6, 7 Vertical Vent Installation Page Exterior run to be included in equivalent vent lengths Install vent pipingLwco Location IV. Water Piping and TrimHow to Test How to WireSupply Water Manifold Piping Page Page Failure to properly pipe gas supply to boiler may Gas PipingGas Ratings Valves Fully Open Page VI. Electrical Internal Boiler Wiring Schematic Diagram Internal Boiler Wiring Ladder Diagram System Controls and Wiring Single Heating Zone Only Wiring Schematic Page Circulator Zoned System Wiring Schematic Zone Valve Zoned System Wiring Schematic Page Module Sizing VII. Modular InstallationDo not manifold vent pipes together Modular Boiler Water Manifold SizingModular Boiler Piping VIII. System Start-up Operating Instructions Ignition Module Terminal Cross-Reference Operating InstructionsGreen LED Status Codes Honeywell Electronic Ignition Troubleshooting Guide Check limit Sequence of OperationGas Flow Rate in Cubic Feet Per Hour Adjust gas input rate to boilerLow water cutoff if so equipped IX. ServiceMain Burners and Firebox Procedure for measuring differential pressure See FigureFlue and Burner Cleanout, 1 Burner Pilot Burner Location Differential Pressure Switch SettingsPage Page XI. Repair Parts Casting Assembly Page Base Assembly Sheet Metal Screw, #8 x 1/2 FAN/CANOPY Assembly Page Burner Assembly Control Panel Assembly Jacket Parts Miscellaneous Parts Carton Avoid Breathing Fiber Particulates and Dust Limited Warranty

PVG specifications

Burnham PVG, an innovative leader in the heating industry, presents a range of high-efficiency gas boilers that are designed specifically for residential applications. Burnham has established a solid reputation for producing reliable and durable heating solutions, with the PVG series exemplifying their commitment to quality and performance.

One of the standout features of the Burnham PVG is its advanced stainless steel heat exchanger. This design not only ensures superior heat transfer but also enhances durability and resistance to corrosion compared to traditional cast iron counterparts. The use of stainless steel contributes to the longevity of the system, allowing homeowners to enjoy efficient heating for years with less risk of breakdown.

The PVG series incorporates cutting-edge modulating technology, which adjusts the boiler’s output to match the heating demand. This modulating feature allows for more precise temperature control, optimizing energy consumption and minimizing fuel costs. Unlike conventional boilers that operate at a fixed output, the ability to modulate enables the PVG to deliver precisely the right amount of energy when needed, thus enhancing overall system efficiency.

In addition to its efficiency and performance capabilities, the Burnham PVG is designed with ease of installation and maintenance in mind. The compact design enables versatile installation options, even in tight spaces or retrofit applications. Furthermore, the accessible panel layout simplifies service and maintenance tasks, allowing HVAC professionals to perform routine checks and repairs with ease.

The PVG series also emphasizes user-friendly operations, featuring intuitive controls that allow for straightforward adjustments and monitoring. With options for direct vent and conventional venting systems, homeowners can select the best installation method for their specific needs and living environment.

Additionally, the Burnham PVG aligns with environmental considerations by meeting stringent emissions standards, contributing to reduced greenhouse gas outputs. With its energy-efficient operation and commitment to sustainability, the PVG series represents a forward-thinking choice for those looking to reduce their carbon footprint while enhancing home comfort.

In summary, Burnham PVG is characterized by its durable stainless steel construction, modulating technology, compact design, user-friendly controls, and eco-conscious performance. This series exemplifies what modern residential heating solutions should aspire to achieve: efficiency, reliability, and sustainability, making it an excellent choice for intelligent energy management in the home.